Adjustment when Replacing the Parts
Handling Finisher Controller PCB Replacements
■ Handling before replacement
• When backup is possible
1. Before replacing the finisher controller PCB, back up the counter values of consumable parts and various adjustment
values to the host machine using the host machine's service mode.
SORTER > FUNCTION > FIN-BK-R
2. Turn OFF/ON the main power switch.
• When backup is impossible
1. Output the service mode setting values by P-PRINT.
COPIER > FUNCTION > MISC-P > P-PRINT
If P-PRINT cannot be output, handling before replacement is not performed. Replace the finisher controller PCB.
■ Preparation/Procedure
“Removing the Finisher Controller PCB (PCB1)” on page 92
■ Handling after replacement
CAUTION:
If the finisher version is old, a message prompting you to update will appear. If this message appears, update it automatically.
If you select to skip the message screen indicating that the combination is not correct, the message will appear every time
you start the host machine unless you disable the message in service mode.
<Related service mode>
Setting of firmware update operation (Lv.2):
COPIER > OPTION > FNC-SW > VER-CHNG
• If backup operation has been performed
1. Write the backup data to the new PCB in the host machine's service mode.
SORTER > FUNCTION > FIN-BK-W
2. Turn OFF/ON the main power switch.
• If backup operation has not been performed
1. If there is the output P-PRINT
Input the adjustment values and setting values in SORTER item. However, in this case, the counter cannot enter.
2. If there is not the output P-PRINT
Enter the values of service mode items recorded on the service label of the finisher rear cover.
5. Adjustment
113
Содержание Inner Finisher-L1
Страница 11: ...Product Overview 1 Features 5 Specifications 6 Name of Parts 9 ...
Страница 46: ...Periodical Service 3 List of Work for Scheduled Servicing 40 ...
Страница 58: ...1x 1x 1 2 5 Remove the Interface Cover 1 2 Claws 2 1 2 4 Parts Replacement and Cleaning 51 ...
Страница 75: ...1x 1 13 Disconnect the 2 Connectors 1 2 Wire Saddles 2 2x 2x 1 1 2 2 4 Parts Replacement and Cleaning 68 ...
Страница 102: ...8 Remove the Return Belt Unit 1 1 Clip 2 1 Bushing 3 3 2 1 4 Parts Replacement and Cleaning 95 ...
Страница 103: ...Adjustment 5 Overview 97 Basic Adjustment 100 Adjustment when Replacing the Parts 113 Service Label 114 ...
Страница 122: ...Troubleshooting 6 Making Initial Checks 116 Processing Tray Area 117 ...
Страница 126: ...APPENDICES Service Tools 120 General Circuit Diagram 121 ...