imageRUNNER ADVANCE C9000S PRO Series Service Guide
b. PRISMAsync Controller Firmware Updates
PRISMAsync Controller firmware updates are available as a service
part and can be ordered by the dealer.
A USB flash drive (USB stick), available for purchase, is used by the
service technician/system engineer to upgrade or restore the
PRISMAsync controller firmware. The process to prepare the USB
stick, to make it ready to install firmware, formats the USB stick
(eliminating all contents) and downloads the new firmware to the USB
stick.
During the PRISMAsync Controller firmware update process, the
current firmware is erased and replaced by firmware installed from the
USB stick. Therefore, it is highly recommended that the service
technician/system engineer backup the system using a separate USP
Flash drive (the USB key), see System Backup. After the Firmware
update, the installed licenses can be restored using the USB key.
Once the USB stick has been used to update firmware on the
PRISMAsync controller, it cannot be used again to update firmware
until the preparation process has been repeated.
3. imageRUNNER ADVANCE Firmware Update
The Service Support Tool
(Version 4.52 or later) is available via the
Canon USA e-Support Center website for updating the following system
components:
•
System Software stored on the Hard Disk Drive (HDD)
•
Language
•
HD Format
•
Remote User Interface (RUI) stored on the HDD
•
MEAP Cont
•
BootROM on the Main Controller Printed Circuit Board (PCB)
When the HDD is replaced, the Service Support Tool
the new HDD and load software. Canon USA will make the data for these
updates available to the dealers via e-Support.
Refer to the Service Manual for complete upgrading procedures.
21 Check the e-Support Center Download Center for the most current version of the Service Support Tool
imageRUNNER ADVANCE C9000S PRO Series Service Guide
March 2015
Revision 2
Page 32