Technical Explanation > MEAP > Maintenance > Formatting and Replacing the HDD
Technical Explanation > MEAP > Maintenance > Formatting and Replacing the HDD
Data backed up using SST in the case of iR-ADV devices
In the case of iR-ADV devices, menus are implemented as MEAP application. Therefore the
following items can be also backed up (stored as Meapbackup.bin).
• Setting items of each menu in the main menu ( Copy, Scan and Send, Fax, Scan and
Store, Access Stored Files, Fax/I-Fax Inbox, ).
• Favorite settings
• Default settings
• Settings of option shortcuts
• Previous settings
• Settings of quick menu
• Button size information
• Wallpaper settings
• Quick menu button information
• Restrict quick menu use
●
Procedure for Backing Up/Restoring the MEAP Application Area
For information on backing up/restoring the MEAP data, refer to Chapter 6, "Backup/Restore."
■
Formatting and Replacing the HDD
●
Outline
If the HDD is broken or does not function correctly due to failure of the system (excluding the
MEAP application), it needs to be formatted or replaced.
When the HDD is formatted or replaced, the files of the MEAP application stored in it will be
lost, so make a backup of the MEAP application area according to "Procedure for Backing
Up/Restoring the MEAP Application Area" if possible. If a backup cannot be made, the MEAP
application and the license files need to be reinstalled.
As for the MEAP counter information, it will not be lost because it is backed up just like the
conventional counter.
If a backup cannot be made, a special license file (a license file for installation with the
expiration date carried over from the current counter value) is required to reinstall the MEAP
application. This special license file is treated as a service tool and cannot be obtained by a
general user.
In order to obtain a special license file, a service technician needs to contact a person in
charge of support of a sales company.
When contacting the person in charge of support, the service technician also needs to
provide the serial number of the device and the name of the MEAP application installed.
In the support departments of regional headquarters of Canon, all license files of the
applications that have been issued are filed according to device serial numbers, enabling you
to obtain a series of license files through a single screen as long as you can identify the serial
number of the device in question.
Содержание imageRUNNER ADVANCE C3325 Series
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 324: ...5 5 Adjustment Adjustment Pickup Feed System Document Exposure System Actions after Replacement ...
Страница 427: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 552: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...
Страница 935: ... Service Tools General Circuit Diagram Backup Data Detail of HDD partition Soft counter specifications Removal Appendix ...
Страница 937: ...III III Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...