imageRUNNER ADVANCE 6200 Series Service Guide
imageRUNNER ADVANCE 6200 Series Service Guide
December 2013
Revision 1
Page 40
VII.
Servicing Notes
A. Power and Plug Requirements
The imageRUNNER ADVANCE 6200 Series Main Unit requires a dedicated
single-phase 120V/20A NEMA 5-20R receptacle for proper operation. Before
installation, confirm that a dedicated NEMA receptacle is available for this
device.
Canon USA Inc. strongly suggests dedicated and properly grounded receptacles
be provided for the optional accessories.
Table 14 – Power and Receptacle Requirements for Main Unit and Accessories
Description
Power Supply
Power Receptacle
imageRUNNER ADVANCE 6200 Series
120 V/20 A
NEMA 5-20R
Paper Deck Unit-A1
From the Main Unit
N/A
Paper Deck Unit-D1
From the Main Unit
N/A
Staple Finisher-P1
From the Main Unit
N/A
Booklet Finisher-P1
From the Main Unit
N/A
External 2/3-Hole Puncher-A1
From the Main Unit
N/A
Document Insertion Unit-L1
120 V/15 A outlet
NEMA 5-15P
Document Insertion/Folding Unit-H1
120 V/15 A outlet
NEMA 5-15P
Canon PCL Printer Kit AV1
From the Main Unit
N/A
Canon PS Printer Kit-AV1
From the Main Unit
N/A
Table 15 – Power and Receptacle Requirements for Controllers
Description
Power Supply
Power Receptacle
imagePASS-U2
120 V/15 A outlet
NEMA 5-15R