Chapter 7
7-26
g) SETTING
Make various settings.
1) Pth
Turn on or off the head pulse rank control function.
Default: OFF
2) RTC
Set RTC (real time clock) after replacing the lithium battery on the main controller PCB.
3) PV AUTO JUDGE
Sets ink saver mode.
Default: OFF
4) NETWORK
See "e-maintenance/imageWARE Remote" for detail.
5) E-RDS
See "e-maintenance/imageWARE Remote" for detail.
6) HEAD DOT INF
Select whether to display the message as the result of non-discharging nozzle detection or not.
Default: ON
7) TSC
Make indication settings about TSC.
T-7-2
h) INITIALIZE
Clear the [DISPLAY] histories, [ADJUST] settings, [COUNTER] values, and other parameters.
Display
Description
DATE yyyy/mm/dd
Set date
TIME
hh:mm
Set time
Number of non-discharging
nozzle (nozzle/2,560-nozzles)
ON
OFF
0-99
Displays a message to check the
printing.
-
100-319
Displays a message to check the head. -
320 or more
Displays a message to replace the head.
Display
Description
TTL PRINT AREA
Select whether to display the total printing area or not (Default:
ON)
INK CONSUMED
Select whether to display the amount of ink consumption or not
(Default: OFF)
DUTY CNT
Select whether to display the Duty counter or not (Default: ON)
DISPLAY DECIMAL
TTL PRINT AREA
Select whether to display the decimal fraction of total printing
area or not (Default: ON)
INK CONSUMED
Select whether to display the decimal fraction of amount of ink
consumption or not (Default: ON)
DUTY CNT
Select whether to display the decimal fraction of Duty counter or
not (Default: ON)
UNIT
TTL PRINT AREA
Set the unit of total printing area
Setting value: LENGTH UNIT* (default)/A4/LETTER
*: The setting is in accord with [Lenght Unit] in the Main menu.
DUTY CNT
Set the unit of Duty counter
Setting value: LENGTH UNIT*/A4 (default)/LETTER
*: The setting is in accord with [Lenght Unit] in the Main menu.
Display
Description
WARNING
Initialize the history of WARNING.
(All displayed contents of [DISPLAY] > [WARNING] will be initialized.)
ERROR
Initialize the history of ERROR.
(All displayed contents of [DISPLAY] > [ERROR] will be initialized.)
JAM
Initialize the history of JAM.
(All displayed contents of [DISPLAY] > [JAM] will be initialized.)
ADJUST
Initialize the value of band adjustment (by user) and head adjustment.
The automatically adjusted value will not be initialized.
W-INK
Initialize the remaining capacity (%) of the maitenance cartridge.
(Clear [COUNTER] > [PRINTER] > [W-INK])
CARRIAGE
Initialize the counter related to carriage unit.
(Clear [COUNTER] > [CARRIAGE])
PURGE
Initialize the counter related to purge unit.
(Clear [COUNTER] > [PURGE])
INK-USE CNT
Initialize the consumption amount of ink.
(Clear [COUNTER] > [INK-USE2], and count up [COUNTER] > [CLEAR] > [CLR-INK
CONSUME])
Содержание image Prograf iPF785 Series
Страница 1: ...Mar 27 2014 Service Manual iPF780 760 750 series iPF785 ...
Страница 9: ...Chapter 1 PRODUCT DESCRIPTION ...
Страница 57: ...Chapter 2 TECHNICAL REFERENCE ...
Страница 117: ...Chapter 3 INSTALLATION ...
Страница 125: ...Chapter 4 DISASSEMBLY REASSEMBLY ...
Страница 133: ...Chapter 4 4 7 3 Remove one screw 1 release two hooks 2 and then remove the output guide middle left 3 F 4 11 1 3 2 2 ...
Страница 175: ...Chapter 4 4 49 2 Shaft Cleaner 1 F 4 97 1 1 ...
Страница 176: ...Chapter 4 4 50 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 98 2 1 ...
Страница 179: ...Chapter 5 MAINTENANCE ...
Страница 186: ...Chapter 6 TROUBLESHOOTING ...
Страница 212: ...Chapter 7 SERVICE MODE ...
Страница 267: ...Mar 19 2014 PARTS CATALOG iPF786 785 781 780 765 760 755 750 ...
Страница 275: ...STAND UNIT ST 33 STAND UNIT ST 34 100V Q51 1767 000 230 KOR Q51 1768 000 Q51 2560 000 Q51 2800 000 ...
Страница 299: ...2 23 FIGURE 09 CUTTER UNIT J12 J7 J11 J31 J34 J33 A A 10 8 1 502 7 5 13 13 9 11 8 501 6 12 2 3 4 14 14 14 15 503 ...
Страница 301: ...2 25 FIGURE 10 PLATEN GUIDE UNIT 1 3 6 2 8 4 5 10 10 10 9 9 11 ...
Страница 326: ......