Chapter 2
6
E584
0001
- Shutter drive motor or finisher controller PCB failure
- Shutter open detection sensor failure
- Shutter clutch failure
- The shutter open sensor did not turn on
when 1000 ms have lapsed since the
shutter unit had performed open
operation, resulting in incomplete open
operation.
- Check the connector of the shutter open sensor.
- Check the connector of the shutter clutch.
- Check the connector of the shutter motor.
- Replace the shutter open sensor.
- Replace the shutter clutch.
- Replace the shutter drive motor.
- Replace the finisher controller PCB.
0002
- Shutter drive motor or finisher controller PCB failure
- Shutter open detection sensor failure
- Shutter clutch failure
- The shutter open sensor did not turn off
when 1000 ms have lapsed since the
shutter unit had performed close
operation, resulting in incomplete close
operation.
- Check the connector of the shutter open sensor.
- Check the connector of the shutter clutch.
- Check the connector of the shutter motor.
- Replace the shutter open sensor.
- Replace the shutter clutch.
- Replace the shutter drive motor.
- Replace the finisher controller PCB.
Display
code
Detail
Code
Main Cause/Symptom Countermeasure