background image

ENG-8

4. 

InfinityCompensation

Mark

For accurate manual focusing of subjects at infinity, 

look through the viewfinder or look at the magnified 

image* on the LCD screen while rotating the 
focusing ring.

To compensate for shifting of the infinity focus 

point that results from changes in temperature, 

there is a margin at the infinity (

) position.

The infinity position at normal temperature is the 

point at which the vertical line of the distance 
scale L mark is aligned with the distance index.

Distance index

Infinity compensation 

mark

* For cameras with Live View shooting capability.

5. Infrared Index

 

The infrared index position is based on a 

wavelength of 800 nm.

 

The compensation amount differs depending on 
the focal length. Use the indicated focal length 
as a guide when setting the compensation 
amount.

 

Be sure to observe the manufacturer’s 

instructions when using infrared film.

 

Use a red filter when you take the picture.

Some EOS cameras cannot use infrared film. See 

the instructions for your EOS camera.

The infrared index corrects the focus setting 

when using monochrome infrared film. Focus on 

the subject manually, then adjust the distance 
setting by moving the focusing ring to the 
corresponding infrared index mark.

COP

Y

Содержание EF11-24mm f/4L USM

Страница 1: ...EF11 24mm f 4L USM Instructions ENG COPY ...

Страница 2: ...ignificantly reduce occurrences of flare and ghost created by quite large incident angles of light 3 Using a fluorine coating on the foremost and rearmost lens surfaces allows adhered dirt to be removed more easily than before 4 Ultrasonic motor USM for fast quiet autofocus 5 Manual focusing is available after the subject comes into focus in autofocus mode ONE SHOT AF 6 Circular aperture for produ...

Страница 3: ...ction or damage Supplementary notes on using the lens and taking pictures Handling Cautions If the lens is taken from a cold environment into a warm one condensation may develop on the lens surface and internal parts To prevent condensation in this case first put the lens into an airtight plastic bag before taking it from a cold to warm environment Then take out the lens after it has warmed gradua...

Страница 4: ...lly available air dust blower Since this lens has a wide angle of view light from bright light sources such as the sun can easily enter the image area Please do not look at bright light sources using the camera s viewfinder Similarly flare and ghost will occur when bright light sources appear in the image area depending on shooting conditions In order to prevent flare and ghost we suggest shooting...

Страница 5: ...ful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televisio...

Страница 6: ...tailed information reference page numbers are provided in parentheses Focus mode switch 7 Distance scale 8 Zoom ring 7 Rubber ring 6 Gelatin filter holder 9 Contacts 6 Lens mount index 6 Focusing ring 7 Built in lens hood COPY ...

Страница 7: ...with the rear end up to prevent the lens surface and contacts from getting scratched If the contacts get soiled scratched or have fingerprints on them corrosion or faulty connections can result The camera and lens may not operate properly If the contacts get soiled or have fingerprints on them clean them with a soft cloth If you remove the lens cover it with the dust cap To attach it properly alig...

Страница 8: ...ys works regardless of the focus mode To zoom rotate the zoom ring Also the minimum focusing distance of the lens changes depending on focal length Focal Length mm Min Focusing Distance m ft Magnification 11 0 32 1 05 0 06 16 0 29 0 95 0 10 24 0 28 0 92 0 16 Be sure to finish zooming before focusing Zooming after focusing can affect the focus Zooming in causes the front lens assembly to extend alo...

Страница 9: ...y compensation mark For cameras with Live View shooting capability 5 Infrared Index The infrared index position is based on a wavelength of 800 nm The compensation amount differs depending on the focal length Use the indicated focal length as a guide when setting the compensation amount Be sure to observe the manufacturer s instructions when using infrared film Use a red filter when you take the p...

Страница 10: ... into the filter holder 7 Filter Sold separately The recessed sections of the lens hood that the cap locks on to are located at the front inside edge of the top and bottom petals Lock knobs The lens s rear lens group moves back toward the rear of the lens camera side the most when the lens is set to the wide end Therefore in order to prevent the rear lens element from making contact with a filter ...

Страница 11: ... II for magnified shots The shooting distance and magnification are shown below MF mode is recommended for accurate focusing Focusing Distance Range mm Magnification Close distance Long distance Close distance Long distance EF12 II 11mm Incompatible 24mm 188 203 0 73 0 53 COPY ...

Страница 12: ...tions and appearance are subject to change without notice Focal Length Aperture 11 24mm f 4 Lens Construction 11 groups 16 elements Minimum Aperture f 22 Angle of View Diagonal 126 05 84 Vertical 95 53 Horizontal 117 10 74 Min Focusing Distance 0 28 m 0 92 ft at 24 mm 0 32 m 1 05 ft at 11 mm Max Magnification 0 16x at 24 mm Field of View Approx 196 x 307 mm 7 72 x 12 09 inch at 0 32 m 1 05 ft 74 x...

Страница 13: ...CT1 8600 000 0814Ni CANON INC 2014 COPY ...

Отзывы: