Service Mode > Numeric Parameter Settings (Numeric Param.) > <024: pseudo RBT transmission level at time of fax/tel switchover>
Service Mode > Numeric Parameter Settings (Numeric Param.) > <024: pseudo RBT transmission level at time of fax/tel switchover>
<006: NCC pause length (post-ID code)>
Use it to set the length of the pause automatically entered between ID code and telephone
number of the other party when the NCC (New Common Carrier) line is used for dialing.
<010: line connection identification length>
Use it to set the time for identifying the line connection. Raise this parameter if errors occur
frequently at time of communication because of the condition of the line.
MEMO:
Any of the following error codes may be indicated because of the condition of the line
##0005, ##0018
The line condition identification time is between when the dial signal is transmitted and
when the line condition is cut for the transmitting party, while it is between when the DIS
signal is transmitted and when the line is cut for the receiving party.
<011: T.30 T1 timer (for reception)>
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant
signal is received).
<013: T.30 EOL timer>
Set it so that the 1-line transmission time is longer for reception to prevent reception errors
caused by a long data length per line (e.g., computer FAX).
<016: time length to first response at time of fax/tel
switchover>
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel
switching function is operating.
<017: pseudo RBT signal pattern ON time length><018:
pseudo RBT signal pattern OFF time length
(short)><019: pseudo RBT signal pattern OFF time
length (long)>
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
<020: pseudo CI signal pattern ON time length><021:
pseudo CI signal pattern OFF time length (short)><022:
pseudo CI signal pattern OFF time length (long)>
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
<023: CNG detention level for fax/tel switchover>
Use it to set the CNG detention level for a fax/tel switchover.
<024: pseudo RBT transmission level at time of fax/tel
switchover>
Use it to set the pseudo transmission level for a fax/tel switchover.
Содержание D1100 Series
Страница 15: ...1 1 Product Overview Product Overview Product Lineups Product Features Specifications Name of Parts ...
Страница 167: ...5 5 Adjustment Adjustment Scanning System Adjustment Electrical Adjustment ...
Страница 170: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Version Up ...
Страница 182: ...7 7 Error Codes Error Codes Error Code Fax Error Code ...
Страница 223: ... Appendex Appendex Service Tools Solvents and Oil List General Timing Chart General Circuit Diagram Appendex ...