background image

E107

4. Operation in Full Mode

ToOtherLens

User

ToAllUser

Copy:

1

y/n

Now Data Copy

Please Wait...

ToOtherLens

User

ToAllUser

Copy:

1

y/

n

ToOtherLens

User

UserCopy  :

AllCopy :

1

y/n

y/n

y/n

ToOtherLens

User

UserCopy  :

AllCopy :

1

y

/n

User

Copy

ToOtherLens

1

Access:

Unlock

Note:   If copying fails, an error 

message is displayed. 

Respond as described in “(3) 

Responding to Errors.”

*1: 

Pressing the Set key in this 

step begins the copying 

process. Note that once 

copying begins, you cannot 

restore the original settings.

*2: 

To avoid problems during 

copying, do not operate 

controls or press the Display 

switch on the source or target 

lenses. Do not perform other 

operations.

MENU

User

1

 × 6

 × 2

Press 

 and then 

.

The display switches to 

Screen B

.

Press 

 twice.

[AllCopy] is underlined, and you can select {y} (yes) or {n} (no).

Press  .

The display switches to the 

AllCopy screen

.

Press  .

[Copy] is underlined, and you can select {y} (yes) or {n} (no).

6

7

8

9

Screen B

AllCopy Screen

Screen A

*1

Continued from previous page

After a message is displayed 
indicating that copying is in 
progress, the display reverts to 

Screen A

.

The settings have now been 

copied between lenses.

*2

Содержание CN8x15

Страница 1: ...Zoom Lens CN7x17 CN8x15 CN10x25 OPERATION MANUAL Information display ENG Read this operation manual before using the product ...

Страница 2: ...Memo ...

Страница 3: ...ENGLISH ...

Страница 4: ...Memo ...

Страница 5: ...l Regulations Included with the product Operation Manual Lens Web Operation Manual Information display Web Quick guide Information display Web Depth of field Web Refer to this Operation Manual Information display for operating instructions and procedures for the information display The copyright for this manual is retained by Canon Inc Unauthorized copying or reproduction in whole or part is prohi...

Страница 6: ...ection E17 2 1 Modes E18 3 Operation in Basic Mode E19 3 1 Configuration from the Top Screen E20 3 1 1 Selecting Basic Mode E21 3 1 2 Top Screen E22 3 1 3 Specifying Auto Iris Gain E24 3 1 4 Assigning Functions to the AUX Switch E25 3 1 5 Auto Adjusting the Mechanical End E26 3 1 6 Assigning Functions to the AUX1 Switch E27 3 1 7 Zoom Tracking ON OFF E28 3 1 8 Assigning Functions to the AUX2 Switc...

Страница 7: ... Adjusting the Mechanical End E80 4 1 6 Specifying Iris Gain E81 4 1 7 Zoom Tracking ON OFF E83 4 1 8 Assigning Functions to the AUX Switch E84 4 1 9 Specifying Iris Torque E85 4 1 10 Assigning Functions to the AUX1 Switch E86 4 1 11 Assigning Functions to the VTR Switch E87 4 1 12 Assigning Functions to the AUX2 Switch E88 4 1 13 Assigning Functions to the RET Switch E89 4 1 14 Specifying Zoom Cu...

Страница 8: ... of Settings E156 5 Operation in Analog Mode E159 5 1 Configuration from the Top Screen E160 5 1 1 Selecting Analog Mode E161 5 1 2 Top Screen E162 5 1 3 Specifying Auto Iris Gain E163 5 1 4 Switching to Basic Mode E164 5 2 Configuration from the Menu Screen E165 5 2 1 User Screen Settings E166 5 3 List of Settings E171 ...

Страница 9: ...ft or right to switch the function to Zoom or Iris Press The display changes from blinking to highlighted indicating con rmation Options D Zoom Iris Description Zoom operation Iris operation D Default value MENU 6 Zoom or 1 2 3 4 Initial Top Screen Note Note on Iris Assignment 1 The seesaw switch will no longer control zooming 2 To control the iris with the rocker switch you must set the iris mode...

Страница 10: ...s are used in this manual Convention Description Example screen Names of screens are underlined The Top screen is displayed Names of setting items are enclosed in square brackets Frame 1 is underlined Names of options are enclosed in curly brackets Select FAST ...

Страница 11: ...e all settings shown on the display Identified with five key names depending on how this interface is used See the following table Using the Control Keys Operation Key Names and Operation Methods Key Operation Details Manual Convention Set key Press Pressed when is displayed or when entering a selection Right key Move right Can be used when is displayed Left key Move left Can be used when is displ...

Страница 12: ...ls see Resetting Values in 3 Operation in Basic Mode or 4 Operation in Full Mode Basic Mode ResetAll User User B y n Full Mode ResetAll User User AllUser 1 y n y n Note For instructions on turning the lens on refer to the camera manual Note The display turns off automatically after two minutes if no control keys are pressed Auto Off However the display remains active as long as the Fol screen is s...

Страница 13: ...Screen Organization 1 INFORMATION DISPLAY ...

Страница 14: ...iguration from the Top Screen in each mode The Top screen contains 9 setting items in Basic mode 15 in Full mode and 3 in Analog mode Initial Top Screen in Basic Mode Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj Items not scrolled Items displayed by scrolling MENU I Tq H A 1 IG 50 Trk OFF Z M A 2 Fr1P Shtl Top Screen in Basic Mode Of the 9 setting items in Basic mode the 8 more common ar...

Страница 15: ...own to scroll down the screen 1 Go to Menu screen 2 Switch users 3 Switch to Basic mode 4 Mechanical end auto adjustment 5 Iris gain settings 6 Zoom tracking ON OFF 7 AUX switch assignment 8 Iris torque settings 9 AUX1 switch assignment 10 VTR switch assignment 11 AUX2 switch assignment 12 RET switch assignment 13 Zoom curve mode settings 14 Seesaw switch assignment 15 Iris A M switch setting Init...

Страница 16: ...ghlighted 1 User screen B 2 Switch screen 3 Preset screen 4 Iris screen 5 Zoom screen 6 Focus screen 7 Info screen 8 Fol screen 1 There is no single Menu screen Instead these 8 screens are collectively referred to as the Menu screen To access these screens select MENU on the Top screen and press the Set key Initially the User screen is displayed To access other screens press left or right Mode Use...

Страница 17: ...single Menu screen Instead these 8 screens are collectively referred to as the Menu screen To access these screens select MENU on the Top screen and press the Set key Initially the User screen is displayed To access other screens press left or right Menu Screen in Full Mode User screen Zoom screen Switch screen Focus screen Preset screen Info screen Iris screen Fol screen No User 1 Name Mode Full ...

Страница 18: ...elected screen is highlighted Mode User Analog Access A Unlock 1 User screen A 1 There is no single Menu screen Instead screens accessed by selecting MENU are collectively referred to as the Menu screen To access this screen select MENU on the Top screen and press the Set key The User screen is now displayed User screen Mode User Analog Access A Unlock ...

Страница 19: ...Mode Selection 2 INFORMATION DISPLAY ...

Страница 20: ...sic Mode Restricted settings and information Recommended for users who do not require sophisticated settings This is the default mode 2 Full Mode All settings and information are available 3 Analog Mode Used when no digital functions are needed For details see 3 Operation in Basic Mode 4 Operation in Full Mode or 5 Operation in Analog Mode ...

Страница 21: ...Operation in Basic Mode 3 INFORMATION DISPLAY ...

Страница 22: ...n be configured on the Top screen in Basic mode The first screen displayed is referred to as the Initial Top screen Status of some items can be checked simply by accessing this screen Initial Top Screen in Basic Mode Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj Items not scrolled Items displayed by scrolling MENU I Tq H A 1 IG 50 Trk OFF Z M A 2 Fr1P Shtl ...

Страница 23: ...om Full to Basic Mode MENU MENU Basic I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H I Gain Adj 1 A Fr1P Trk OFF I Tq H Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj Initial Top Screen in Full Mode Initial Top Screen in Basic Mode MENU Basic Press Basic is highlighted Press The mode switches and the Initial Top screen in Basic mode is displayed 1 2 ...

Страница 24: ...ms can be checked simply by accessing this screen Shown in the figure below 1 1 Inside Items that show the current setting status Example Shtl A 1 indicates that the AUX1 switch is assigned to the Shuttle function 1 4 2 3 5 7 6 8 9 White numbers against a black background indicate the number of the switch on a drive unit to which the function is assigned Trk OFF Shtl A 1 A 2 I Tq H Adj IG 50 A Fr1...

Страница 25: ...e Preset 1 function but it can be reassigned as needed See 3 1 4 Assigning Functions to the AUX Switch 1 4 2 3 5 7 6 8 9 I Tq Iris torque Adjust the level of torque in manual control of the iris ring as needed See 3 1 9 Specifying Iris Torque 1 4 2 3 5 7 6 8 9 Adj Mechanical end auto adjustment Perform automatic adjustment of the mechanical end in zoom focus and iris operations on the lens and dri...

Страница 26: ...htl A 1 A 2 A Fr1P Fr1P I Tq H Adj MENU IG 51 IG 51 Trk OFF Shtl A 1 A 2 A Fr1P Fr1P I Tq H Adj Note Do the following when adjusting gain while checking iris operation Confirm that the drive unit A M switch is set to Auto mode Set the camera iris mode to Auto Note As you look at the lens iris ring set it to the position of maximum gain at which focus hunting does not occur Note The current iris ga...

Страница 27: ...2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset speed Framing Preset1 switch max speed Framing Preset2 switch preset speed Framing Preset2 switch max speed Speed Preset switch Shuttle Shot switch No function VTR switch RET switch D Default value MENU Shtl A or Press The default function is highlighted Press The display starts blinking Press or Press left or right until you reach...

Страница 28: ...lens and drive unit Note If Auto Adjustment Error Lens Interface Non Connected is displayed after adjustment contact Canon or your dealer Press and then Your selection is now highlighted Press The display switches to the Auto Adjustment screen Press and then Adjustment now begins During adjustment the screen blinks After this adjustment is finished Press after adjustment to return to Screen A 1 2 ...

Страница 29: ...reset switch Shuttle Shot switch No function VTR switch RET switch D Default value MENU 2 Shtl A or Press twice The default function is highlighted Press The display starts blinking Press or Press left or right until you reach the desired function Press The display changes from blinking to highlighted indicating confirmation Shtl A 1 NON A 1 Shtl MENU A 1 Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1...

Страница 30: ...fault value is restored on startup Trk OFF Trk ON Shtl A 1 A 2 IG 50 A Fr1P Fr1P I Tq H Z M MENU Trk ON Trk OFF Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj Shtl A 1 A 2 IG 50 A Fr1P Fr1P I Tq H Adj MENU Press twice and once The default setting is highlighted Press The display starts blinking Press or Press left or right to switch the function ON or OFF Press The display changes from bli...

Страница 31: ...ed indicating confirmation Fr1P A 2 RET A 2 A 2 MENU Fr1P Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj Trk OFF Shtl A 1 IG 50 I Tq H Z M A 2 MENU RET Trk OFF Shtl A 1 IG 50 I Tq H Z M Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset speed Framing Preset1 switch max speed Framing Preset2 switch preset speed Framing Preset2 switch max speed Spee...

Страница 32: ... blinking Press or Press left or right to switch the function to H or L Press The display changes from blinking to highlighted indicating confirmation I Tq H I Tq L A 2 Fr1P I Tq H Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj MENU Trk OFF Shtl A 1 IG 50 Z M A 2 Fr1P I Tq L MENU Trk OFF Shtl A 1 IG 50 Z M Options D H L Description High torque Low torque D Default value MENU 3 I Tq H or 1 ...

Страница 33: ...om seesaw switch Note Another screen is displayed when this setting is configured Press four times Your selection is now highlighted Press The display switches to the CurveMode screen Press Seesaw is underlined The default value is highlighted Press or Press left or right until you reach the desired value Press The display reverts to Screen A 1 9 Responsiveness to zoom mode adjustment Maximum Zoom...

Страница 34: ...value is highlighted Press or Press left or right until you reach the desired value Press The display reverts to Screen A Options 1 2 3 4 D 5 6 7 8 9 D Default value MENU 4 Z M 2 or Specifying Analog Demand Responsiveness Configure the responsiveness of zoom speed adjustment in response to pressing the analog demand thumb ring Note Another screen is displayed when this setting is configured 1 2 3 ...

Страница 35: ...h screen Preset screen Iris screen Zoom screen Focus screen Info screen and Fol screen Select MENU on the Top screen and press the Set key to access the User screen initially Press left or right to access the 7 other screens See the following figure There is no single Menu screen Instead these 8 screens are collectively referred to as the Menu screen Setting items labeled Top next to the function ...

Страница 36: ... User Screen Settings User B is the user in Basic mode The following setting items can be configured on the User Screen Switching Modes Resetting Values Locking Functions Mode User Basic Access ResetAll B Unlock User Screen in Basic Mode ...

Страница 37: ...to Full or Analog mode as needed Important The new mode setting is retained even after the lens is turned off Press The display switches to the User screen Press Mode is underlined The previous mode is highlighted Press or Press left or right until you reach the desired mode Options D Basic Full Analog Save Settings Basic Mode Full Mode Analog Mode D Default value MENU User B or 1 2 3 Initial Top ...

Страница 38: ...ss The display switches to the User screen Press twice ResetAll is underlined Press The display switches to the Reset screen Press A confirmation message is displayed about resetting information for the selected user Note You can cancel resetting and restore the original values at any time before pressing in step 5 To return to the previous screen press up To cancel resetting and turn off the disp...

Страница 39: ...tings of certain functions Mode User Basic Access ResetAll B Unlock Mode User Basic Access ResetAll B Lock Unlocked Locked Note In lock mode only the following items can still be configured and other settings are locked Preset data Shuttle shot position Frame preset position Preset speed Auto iris gain setting Press The display switches to the User screen Press three times The previous or default ...

Страница 40: ...password is used on this model The password you enter each time to lock settings is the password used to unlock them For this reason we recommend making a note of the password each time If you forget the password contact Canon or your dealer Passwords can be blank or up to 8 digits Characters supported in passwords Options D _ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j...

Страница 41: ... A Fr1P Fr1P I Tq H Adj 2 Unlocking Settings Press The display switches to the User screen Press three times The previous or default value is highlighted Enter the password and press The password you entered to lock settings is the password used to unlock them Press Press and then The settings are now unlocked Options D Unlock Lock D Default value MENU 3 Entering Passwords DISPLAY Initial Top Scre...

Страница 42: ...ngs The following setting items can be configured on the Switch screen Assigning Functions to the AUX Switch Top Assigning Functions to the AUX1 Switch Top Assigning Functions to the AUX2 Switch Top Items labeled Top can also be modified from the Top screen ...

Страница 43: ... is highlighted Press or Press left or right until you reach the desired function Assigning Functions to the AUX Switch Top The AUX switch can be programmed to activate a function of your choice Initial Top Screen Switch Screen Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset speed Framing Preset1 switch max speed Framing Preset2 switch preset speed Fra...

Страница 44: ...hoice Press and then The display switches to the Switch screen Press twice AUX1 is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options Fr1P Fr1F Fr2P Fr2F Sped D Shtl NON VTR RET Description Framing Preset1 switch preset speed Framing Preset1 switch max speed Framing Preset2 switch pre...

Страница 45: ...ce Press and then The display switches to the Switch screen Press three times AUX2 is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset speed Framing Preset1 switch max speed Framing Preset2 switch ...

Страница 46: ...asic Mode 3 2 3 Preset Screen Settings The following setting items can be configured on the Preset screen Switching What Frame Preset 1 Controls Switching What Frame Preset 2 Controls Specifying the Preset Mode Zoom Speed ...

Страница 47: ...he previous or default value is highlighted Press or Switching What Frame Preset 1 Controls Switch what frame preset 1 controls as needed Zoom Move the zoom position to the position in memory Focus Move the focus position to the position in memory Z F Move the zoom and focus position to the position in memory Initial Top Screen Preset Screen Screen A Frame1 Screen Options D Zoom Focus Z F Descript...

Страница 48: ... The previous or default value is highlighted Press or Switching What Frame Preset 2 Controls Switch what frame preset 2 controls as needed Zoom Move the zoom position to the position in memory Focus Move the focus position to the position in memory Z F Move the zoom and focus position to the position in memory Initial Top Screen Preset Screen Screen A Frame2 Screen Options D Zoom Focus Z F Descri...

Страница 49: ...lighted Press or Press left or right until you reach the desired value Specifying the Preset Mode Zoom Speed Configure the zoom speed from any position to the position in memory as needed To adjust the value use either the Memo button refer to the operation manual Lens or display operations Regardless of the method of adjustment used the most recent setting takes precedence Initial Top Screen Pres...

Страница 50: ...n be configured on the Iris screen Specifying Iris Gain 1 Specifying Auto Iris Gain Top 2 Specifying Remote Iris Gain Specifying Iris Torque Top Iris Compensation ON OFF Iris Close Detection ON OFF Focus Demand Iris Control ON OFF Items labeled Top can also be modified from the Top screen ...

Страница 51: ...ode to Auto Note As you look at the lens iris ring set it to the position of maximum gain at which focus hunting does not occur Note The current iris gain value is retained even if you reset other settings as described in 3 2 1 Resetting Values For this reason you will no longer be able to view the default setting If necessary make a note of the default setting before adjusting this value Press on...

Страница 52: ...Remote Note The current iris gain value is retained even if you reset other settings as described in 3 2 1 Resetting Values For this reason you will no longer be able to view the default setting If necessary make a note of the default setting before adjusting this value Press once and three times The display switches to the Iris screen Press I Gain is underlined Press The display switches to the I...

Страница 53: ...Specify the desired level of torque in manual control of the iris ring Press once and three times The display switches to the Iris screen Press twice Torque is underlined The previous or default function is highlighted Press or Press left or right to switch the function to High or Low Initial Top Screen Iris Screen Options D High Low Description High torque Low torque D Default value MENU 3 Iris 2...

Страница 54: ... of light Press once and three times The display switches to the Iris screen Press three times Comp is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Iris Screen Options D ON OFF Description Iris compensation No iris compensation D Default value MENU 3 Iris 3 or Note The iris may not fully close in some ca...

Страница 55: ...ress once and three times The display switches to the Iris screen Press four times Close is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Iris Screen Options D OFF ON Description No close detection Close detection D Default value MENU 3 Iris 4 or Note With some cameras iris compensation may conflict with ...

Страница 56: ...us demand can be switched on or off Press once and three times The display switches to the Iris screen Press five times Controller is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Iris Screen Options ON D OFF Description Iris controlled with focus demand Iris not controlled with focus demand D Default val...

Страница 57: ...sic Mode 3 2 5 Zoom Screen Settings The following setting items can be configured on the Zoom screen Specifying Seesaw Switch Responsiveness Specifying Analog Demand Responsiveness Demand Based Zoom Speed Adjustment ON OFF ...

Страница 58: ... this setting is configured Press once and four times The display switches to the Zoom screen Press or Press left or right until you reach the desired function Press CurveMode is underlined Press Seesaw is underlined The previous or default value is highlighted Press The display switches to the CurveMode screen Press The display reverts to Screen A Initial Top Screen Zoom Screen Screen A CurveMode...

Страница 59: ...en this setting is configured Press once and four times The display switches to the Zoom screen Press or Press left or right until you reach the desired function Press CurveMode is underlined Press twice Demand is underlined The previous or default value is highlighted Press The display switches to the CurveMode screen Press The display reverts to Screen A Initial Top Screen Zoom Screen Screen A C...

Страница 60: ...e or disable adjustment of the maximum drive unit zoom speed based on the zoom demand Press once and four times The display switches to the Zoom screen Press twice VR Dem is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Zoom Screen Options D ON OFF Description Enabled Disabled D Default value MENU 4 Zoom ...

Страница 61: ...E59 3 Operation in Basic Mode 3 2 6 Focus Screen Settings The following setting items can be configured on the Focus screen Specifying Focus Demand Responsiveness ...

Страница 62: ...ress left or right until you reach the desired function Press CurveMode is underlined Press ADemand is underlined The previous or default value is highlighted Press The display switches to the CurveMode screen Press The display reverts to Screen A Initial Top Screen Focus Screen Screen A CurveMode Screen Options 1 to 9 Description Large curve Small curve Default value 5 MENU 3 Focus or Note These ...

Страница 63: ... Numbers Specifying the 3D Function For information on specifying the 3D function see the instruction manual of the BC 100 3D cable Specifying Encoder Output Serial Communication with Camera ON OFF Specifying the Input Route for Command Signals from the Camera Specifying the Technology Distance Unit Checking Lens Drive Unit Communication ...

Страница 64: ...king Serial Numbers Check lens and drive unit serial numbers as needed Press once and twice The display switches to the Info screen Press S N is underlined Press The lens and drive unit serial numbers are displayed Initial Top Screen Info Screen MENU 2 Info B 1 2 3 Note The serial number of the lens is not displayed when no power is being supplied to the lens from the camera mount ...

Страница 65: ...e or disable encoder output as needed Enabling output enables virtual connector output For details contact Canon or your dealer Press once and twice The display switches to the Info screen Press three times Encoder is underlined Press or Press left or right to switch the function ON or OFF Initial Top Screen Info Screen Options D OFF ON Description Output disabled Output enabled D Default value ME...

Страница 66: ...u to switch between auto control detection and analog control By default this setting is ON enabling auto detection of whether serial or analog control is used To restrict the interface to analog control set it to OFF Press once and twice The display switches to the Info screen Press four times CamSeri is underlined Press or Press left or right to switch the function ON or OFF Initial Top Screen I...

Страница 67: ... via the mount are given priority However the command signals via the 12 pin cable are received automatically if no command signals are input via the mount When the Cable setting is selected only command signals received via the 12 pin cable are used Press once and twice The display switches to the Info screen Press five times I Fprior is underlined Press or Press left or right to switch the funct...

Страница 68: ...ormation sent for the actual subject distance hyperfocal distance subject distance at close range and infinity and entrance pupil position is expressed in the specified unit Note Any distance unit set on the camera takes precedence Press once and twice The display switches to the Info screen Press six times i is underlined Press Press Units is underlined The previous or default value is highlighte...

Страница 69: ...atus of communication between the lens and drive unit as follows Press once and twice The display switches to the Info screen Press seven times State is underlined Press Press Lens is underlined Press This screen indicates normal communication If Non connected is displayed contact Canon or your dealer MENU 2 Info 7 1 2 3 4 5 Initial Top Screen Info Screen Note Non connected is displayed when no po...

Страница 70: ...E68 3 Operation in Basic Mode 3 2 8 Fol Screen Settings The following setting items can be configured on the Fol screen Viewing Lens Follow Settings Iris Zoom Focus ...

Страница 71: ...f mechanical iris zoom and focus operations expressed as relative values in the range of 0 1000 Press and then The display switches to the Fol screen showing relative follow iris zoom and focus values Initial Top Screen Fol Screen MENU Fol B Note As long as the Fol screen is shown the display will not turn off automatically after 2 minutes if left idle To turn off the display press the Display swi...

Страница 72: ...r1P VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl NON Adj n y n A 1 Shtl VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl NON Trk OFF OFF ON A 2 Fr1P VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl NON I Tq H H L Z M To 2 on the next page Escape Operation Jump to user 0 setting status Hold down both the Display switch and Set key for at least 2 seconds ...

Страница 73: ... 01 99 Torque High High Low Comp ON ON OFF Close OFF OFF ON Controller OFF OFF ON Zoom CurveMode Seesaw 5 1 9 2 Demand 5 1 9 VR Dem ON ON OFF Focus CurveMode ADemand 5 1 9 Info S N Lens 8 digit serial number D U 8 digit serial number 3D 1 OFF OFF ON Encoder OFF OFF ON CamSeri ON OFF ON I Fprior Mount Mount Cable i Unit Feet Feet Meters State Lens Fol 3 Iris 0000 1000 Zoom 0000 1000 Focus 0000 1000...

Страница 74: ...Memo ...

Страница 75: ...Operation in Full Mode 4 INFORMATION DISPLAY ...

Страница 76: ... items can be configured on the Top screen in Full mode The first screen displayed is referred to as the Initial Top screen Status of some items can be checked simply by accessing this screen Items not scrolled Items displayed by scrolling MENU 1 Norm AM Zoom RET R A 2 Fr1P Z M Initial Top Screen in Full Mode I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H ...

Страница 77: ...OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj 4 1 1 Selecting Full Mode Basic mode is the default mode but Full mode can be accessed as follows Switching from Basic to Full Mode Initial Top Screen in Basic Mode User Screen in Basic Mode MENU Full Press Press Basic is highlighted Press Full is now highlighted indicating confirmation 1 2 3 ...

Страница 78: ...n be accessed by pressing down to scroll down the screen See the following figure Status of some items can be checked simply by accessing this screen Shown in the figure below 1 1 Inside Items that show the current setting status Example Shtl A 1 indicates that the AUX1 switch is assigned to the Shuttle function 9 11 12 13 15 14 1 3 5 10 4 8 2 7 6 White numbers against a black background indicate ...

Страница 79: ... focus and iris operations on the lens and drive unit See 4 1 5 Auto Adjusting the Mechanical End 9 11 12 13 15 14 1 3 5 10 4 8 2 7 6 R RET switch By default the RET switch for a drive unit is assigned to the Return function but it can be reassigned as needed See 4 1 13 Assigning Functions to the RET Switch 9 11 12 13 15 14 1 3 5 10 4 8 2 7 6 I Gain Iris gain Adjust the auto iris gain or the remot...

Страница 80: ...ails see 4 1 17 Escape Operation Selecting user 0 restores the default settings except for the auto and remote iris gain values and encoder output setting Switch to the desired user 0 9 from the Top screen Configure advanced settings for these users from the Menu screen See 4 2 Configuration from the Menu Screen Press The previous or default value is highlighted Press The display starts blinking P...

Страница 81: ... A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj 4 1 4 Switching to Basic Mode Basic Switch to Basic mode from the Top screen as needed Switching from Full to Basic Mode Initial Top Screen in Full Mode Initial Top Screen in Basic Mode Press Basic is highlighted Press The mode switches and the Initial Top screen in Basic mode is displayed 1 2 MENU Basic ...

Страница 82: ...non or your dealer MENU Adj Lens AutoAdjust OK y n Auto Adjustment Succeeded Lens Interface Connected I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H I Gain 1 A Fr1P Basic Trk OFF I Tq H Initial Top Screen Screen A MENU Adj Press and then Your selection is now highlighted Press The display switches to the Auto Adjustment screen Press and then Adjustment now begins During adjustment the screen blinks...

Страница 83: ...imum gain Default Varies depending on the factory set value but corresponds to the value determined with the iris gain adjustment trimmer MENU 2 I Gain or Note Do the following when adjusting gain while checking iris operation Confirm that the drive unit A M switch is set to Auto mode Set the camera iris mode to Auto Note As you look at the lens iris ring set it to the position of maximum gain at ...

Страница 84: ...ault value 90 MENU 2 I Gain 2 or Note Do the following when adjusting gain while checking iris operation Confirm that the drive unit A M switch is set to Auto mode Set the camera iris mode to Remote Note The current iris gain value is retained even if you reset other settings as described in 4 2 1 Resetting Values For this reason you will no longer be able to view the default setting If necessary ...

Страница 85: ...mportant First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press twice and once The previous or default value is highlighted Press The display starts blinking Press or Press left or right to switch the function ON or OFF Press The display changes from blinking to highlighted indicating confirmation 1 2 3 4 ...

Страница 86: ...n Settings Switching Users Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset speed Framing Preset1 switch max speed Framing Preset2 switch preset speed Framing Preset2 switch max speed Speed Preset switch Shuttle Shot switch No function VTR switch RET switch D Default value MENU 3 A Fr1P or Press three times The previous or default function is highlighte...

Страница 87: ...ant First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press three times and once The previous or default function is highlighted Press The display starts blinking Press or Press left or right to switch the function to H or L Press The display changes from blinking to highlighted indicating confirmation Opti...

Страница 88: ...er Screen Settings Switching Users Initial Top Screen Press four times The previous or default function is highlighted Press The display starts blinking Press or Press left or right until you reach the desired function Press The display changes from blinking to highlighted indicating confirmation 1 2 3 4 Options Fr1P Fr1F Fr2P Fr2F Sped D Shtl NON VTR RET Description Framing Preset1 switch preset ...

Страница 89: ...User Screen Settings Switching Users Initial Top Screen Press four times and once The previous or default function is highlighted Press The display starts blinking Press or Press left or right until you reach the desired function Press The display changes from blinking to highlighted indicating confirmation 1 2 3 4 Options D VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl Description VTR switch RET switch F...

Страница 90: ...er Screen Settings Switching Users Initial Top Screen Press five times The previous or default function is highlighted Press The display starts blinking Press or Press left or right until you reach the desired function Press The display changes from blinking to highlighted indicating confirmation 1 2 3 4 Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset ...

Страница 91: ... User Screen Settings Switching Users Initial Top Screen Press five times and once The previous or default function is highlighted Press The display starts blinking Press or Press left or right until you reach the desired function Press The display changes from blinking to highlighted indicating confirmation 1 2 3 4 Options VTR D RET Fr1P Fr1F Fr2P Fr2F Sped Shtl Description VTR switch RET switch ...

Страница 92: ...t First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press seven times Your selection is now highlighted Press The display switches to the CurveMode screen Press Seesaw is underlined The previous or default value is highlighted Press or Press left or right until you reach the desired value Press The display ...

Страница 93: ... the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press six times Your selection is now highlighted Press The display switches to the CurveMode screen Press twice Demand is underlined The previous or default value is highlighted Press or Press left or right until you reach the desired value Press The display reverts to Sc...

Страница 94: ...Press The display starts blinking Press or Press left or right to switch the function to Zoom or Iris Press The display changes from blinking to highlighted indicating confirmation Options D Zoom Iris Description Zoom operation Iris operation D Default value MENU 6 Zoom or 1 2 3 4 Initial Top Screen Note Note on Iris Assignment 1 The seesaw switch will no longer control zooming 2 To control the ir...

Страница 95: ...ttings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press seven times The previous or default function is highlighted Press The display starts blinking Press or Press left or right until you reach the desired function Press The display changes from blinking to highlighted indicating confirmation Options D Norm Reve Auto Manu Description Normal oper...

Страница 96: ...er 0 Auto and remote iris gain values encoder output setting and camera follow voltage adjustments Hold down both the Display switch and for at least 2 seconds One of the following messages is displayed depending on the current user before the operation User 0 User 0 Reset Now User 1 9 Escape To User 0 The Initial Top screen is displayed 1 2 Desired Screen Initial Top Screen From User 0 From Users...

Страница 97: ...n Preset screen Iris screen Zoom screen Focus screen Info screen and Fol screen Select MENU on the Top screen and press the Set key to access the User screen initially Press left or right to access the 7 other screens See the following figure There is no single Menu screen Instead these 8 screens are collectively referred to as the Menu screen Setting items labeled Top next to the function title c...

Страница 98: ...Users Top Naming Users Resetting Values 1 Resetting One User s Settings 2 Resetting All Users Settings Copying Settings Between Individual Users Copying Settings Between Lenses 1 Copying One User s Settings to Another Lens 2 Copying All Users Settings to Another Lens 3 Responding to Errors Locking Functions Items labeled Top can also be modified from the Top screen User Screen in Full Mode Mode Us...

Страница 99: ...een Press Mode is underlined The previous mode is highlighted Press or Press left or right until you reach the desired mode Switching Modes Switch to Basic or Analog mode as needed Important The new mode setting is retained even after the lens is turned off Initial Top Screen User Screen Options D Basic Full Analog Save Settings Basic Mode Full Mode Analog Mode D Default value MENU User 1 or 1 2 3...

Страница 100: ...r Press The display switches to the User screen Press twice No is underlined The previous or default value is highlighted Press or Press left or right until you reach the desired mode Initial Top Screen User Screen Options 0 D 1 2 3 4 5 6 7 8 9 Save Settings Not supported Although settings cannot be saved they can be changed temporarily Switching users or turning the lens off will restore default ...

Страница 101: ...ng Users Press The display switches to the User screen Press three times Name is underlined Press The first dash is highlighted indicating that you can edit it Enter the name Entering Name Press up down to find characters and left right to move the cursor or make corrections Press the to confirm the name The display reverts to Title Name 1 2 3 4 5 Initial Top Screen User Screen Title Name Title Na...

Страница 102: ...s four times ResetAll is underlined Press The display switches to the Reset screen Press A confirmation message is displayed about resetting information for the selected user Note You can cancel resetting and restore the original values at any time before pressing in step 5 To return to the previous screen press up To cancel resetting and turn off the display press the Display switch User Screen T...

Страница 103: ...tep 5 To return to the previous screen press up To cancel resetting and turn off the display press the Display switch Note Iris gain values encoder output setting and camera follow voltage adjustments are not reset The current value is retained Note There is no need to switch users Press and then Press The display switches to the User screen Press four times ResetAll is underlined Press The displa...

Страница 104: ... Display switch Press or Press left or right until you reach the user to copy settings to Press Copy is underlined and you can select y yes or n no Press The display switches to the User screen Press five times Copy is underlined Press The display switches to the Copy screen Press To No is underlined 1 2 3 4 5 6 Initial Top Screen User Screen Screen A Copy Screen Continued on next page Copying Set...

Страница 105: ...eration in Full Mode ResetAll User Copy ToOtherLens 1 Press and then Settings are copied to the specified user number and the display reverts to Screen A 7 MENU User 1 5 or Screen A Continued from previous page ...

Страница 106: ...n connector of the zoom focus remote of the target lens 2 Turn on the source and target lenses 3 Press the Display switch on the source lens to turn on the display Leave the source lens display off Note You can cancel copying and restore the original values at any time before pressing in step 11 To return to the previous screen press up To cancel copying and turn off the display press the Display ...

Страница 107: ...original settings 2 To avoid problems during copying do not operate controls or press the Display switch on the source or target lenses Do not perform other operations MENU User 1 6 or Press and then Press The display switches to the Target user selection screen The display switches to the Copy selection screen Press To No is underlined Press or Press left or right until you reach the number of th...

Страница 108: ...om focus remote of the target lens 2 Turn on the source and target lenses 3 Press the Display switch on the source lens to turn on the display Leave the source lens display off Note You can cancel copying and restore the original values at any time before pressing in step 9 To return to the previous screen press up To cancel copying and turn off the display press the Display switch Press and then ...

Страница 109: ...you cannot restore the original settings 2 To avoid problems during copying do not operate controls or press the Display switch on the source or target lenses Do not perform other operations MENU User 1 6 2 Press and then The display switches to Screen B Press twice AllCopy is underlined and you can select y yes or n no Press The display switches to the AllCopy screen Press Copy is underlined and ...

Страница 110: ...nfirm that the drive unit of the target lens is the same model Settings cannot be copied between lenses of different generations of drive units Contact Canon or your dealer for details on models of drive unit that can be used to copy settings Copy Error Confirm that the dedicated cable 20 pin 20 pin is connected The message at left is displayed if the lenses are disconnected during copying if a po...

Страница 111: ... Tq H I Gain Adj MENU Lock A Fr1P Basic Trk OFF I Tq H Unlocked Locked Note 1 User numbers 0 9 in the user number field indicate users that are unlocked Lock in the user number field indicate users that are locked 2 In lock mode only the following items can still be configured and other settings are locked Preset data Shuttle shot position Frame preset position Preset speed Zoom tracking position ...

Страница 112: ...word is used on this model The password you enter each time to lock settings is the password used to unlock them For this reason we recommend making a note of the password each time If you forget the password contact Canon or your dealer Passwords can be blank or up to 8 digits Characters supported in passwords Options D _ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l...

Страница 113: ...king Settings Settings can be unlocked in two ways as follows Unlocking Setting 1 Press Press The display starts blinking Enter the password and press The password you entered to lock settings is the password used to unlock them Press or Press and then Lock changes to the user number The previously locked user number is displayed Options D Unlock Lock D Default value MENU Lock or Entering Password...

Страница 114: ...e No 1 1 I Gain Adj MENU Lock A Fr1P Basic Trk OFF I Tq H Unlocking Setting 2 Press The display switches to the User screen Press seven times Enter the password and press The password you entered to lock settings is the password used to unlock them Press Press and then The settings are now unlocked MENU 7 Entering Passwords Initial Top Screen User Screen 1 2 3 4 5 ...

Страница 115: ...ing Functions to the AUX Switch Top Assigning Functions to the AUX1 Switch Top Assigning Functions to the AUX2 Switch Top Assigning Functions to the VTR Switch Top Assigning Functions to the RET Switch Top Specifying Iris A M Switch Top Assigning Functions to the Seesaw Top Items labeled Top can also be modified from the Top screen ...

Страница 116: ...n Assigning Functions to the AUX Switch Top The AUX switch can be programmed to activate a function of your choice Important First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Initial Top Screen Switch Screen Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset speed ...

Страница 117: ...4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press and then The display switches to the Switch screen Press twice AUX1 is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options Fr1P Fr1F Fr2P Fr2F Sped D Shtl NON VTR RET Description Framing Preset1 switch preset spe...

Страница 118: ...3 Switching Users or 4 2 1 User Screen Settings Switching Users Press and then The display switches to the Switch screen Press three times AUX2 is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options D Fr1P Fr1F Fr2P Fr2F Sped Shtl NON VTR RET Description Framing Preset1 switch preset s...

Страница 119: ... 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press and then The display switches to the Switch screen Press four times VTR is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options Fr1P Fr1F Fr2P Fr2F Sped Shtl D VTR RET Description Framing Preset1 switch preset sp...

Страница 120: ... 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press and then The display switches to the Switch screen Press five times RET is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options Fr1P Fr1F Fr2P Fr2F Sped Shtl VTR D RET Description Framing Preset1 switch preset spee...

Страница 121: ...whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press and then The display switches to the Switch screen Press six times A M is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options D Norm Reve Auto Manu Description Normal ...

Страница 122: ... times SSaw is underlined The previous or default function is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Switch Screen Options D Zoom Iris Description Zoom operation Iris operation D Default value MENU Switch 1 7 or 1 2 3 Note Note on Iris Assignment 1 The seesaw switch will no longer control zooming 2 To control the iris with the rocker switch...

Страница 123: ...wing setting items can be configured on the Preset screen Switching What Frame Preset 1 Controls Switching What Frame Preset 2 Controls Specifying the Preset Mode Zoom Speed Specifying Zoom Start Responsiveness for Presets Specifying Zoom Stop Responsiveness for Presets ...

Страница 124: ... 1 Controls Switch what frame preset 1 controls as needed Zoom Move the zoom position to the position in memory Focus Move the focus position to the position in memory Z F Move the zoom and focus position to the position in memory Important First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Initial Top Scree...

Страница 125: ...et 2 Controls Switch what frame preset 2 controls as needed Zoom Move the zoom position to the position in memory Focus Move the focus position to the position in memory Z F Move the zoom and focus position to the position in memory Important First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Initial Top Scr...

Страница 126: ...he Preset Mode Zoom Speed Configure the zoom speed from any position to the position in memory as needed To adjust the value use either the Memo button refer to the operation manual Lens or display operations Regardless of the method of adjustment used the most recent setting takes precedence Important First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users ...

Страница 127: ...screen Press Start is underlined The previous or default value is highlighted Press or Press left or right until you reach the desired value Press The display reverts to Screen A Specifying Zoom Start Responsiveness for Presets Specify initial responsiveness in zooming for preset operations Initial Top Screen Preset Screen Screen A ZMovement Screen Options 00 to D 99 Description Start gradually St...

Страница 128: ...screen Press twice Stop is underlined The previous or default value is highlighted Press or Press left or right until you reach the desired value Press The display reverts to Screen A Specifying Zoom Stop Responsiveness for Presets Specify final responsiveness in zooming for preset operations Initial Top Screen Preset Screen Screen A ZMovement Screen Options 00 to 99 Description Stop gradually Sto...

Страница 129: ...be configured on the Iris screen Specifying Iris Gain 1 Specifying Auto Iris Gain Top 2 Specifying Remote Iris Gain Top Specifying Iris Torque Top Iris Compensation ON OFF Iris Close Detection ON OFF Focus Demand Iris Control ON OFF Items labeled Top can also be modified from the Top screen ...

Страница 130: ...onfirm that the drive unit A M switch is set to Auto mode Set the camera iris mode to Auto Note As you look at the lens iris ring set it to the position of maximum gain at which focus hunting does not occur Note The current iris gain value is retained even if you reset other settings as described in 4 2 1 Resetting Values For this reason you will no longer be able to view the default setting If ne...

Страница 131: ...m that the drive unit A M switch is set to Auto mode Set the camera iris mode to Remote Note The current iris gain value is retained even if you reset other settings as described in 4 2 1 Resetting Values For this reason you will no longer be able to view the default setting If necessary make a note of the default setting before adjusting this value Press once and three times The display switches ...

Страница 132: ...First switch to the user for whom the settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press once and three times The display switches to the Iris screen Press twice Torque is underlined The previous or default function is highlighted Press or Press left or right to switch the function to High or Low Initial Top Screen Iris Screen Options D Hi...

Страница 133: ...1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press once and three times The display switches to the Iris screen Press three times Comp is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Iris Screen Options D ON OFF Description Iris compensation No iris compensation D Default value MENU ...

Страница 134: ... see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press once and three times The display switches to the Iris screen Press four times Close is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Iris Screen Options D OFF ON Description No close detection Close detection D Default value ME...

Страница 135: ... the Iris screen Press five times Controller is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Options ON D OFF Description Iris controlled with focus demand Iris not controlled with focus demand D Default value MENU 3 Iris 5 or Displayed when Comp is set to ON 1 2 3 㧖 Iris I Gain Torque High Comp ON Iris ...

Страница 136: ... Stop Responsiveness Specifying Zoom Mechanical End Stop Responsiveness Specifying Seesaw Switch Responsiveness Top Specifying Analog Demand Responsiveness Top Specifying Maximum Zoom Speed Control Specifying Minimum Zoom Speed Control Specifying Servo Type from Zoom Demand Demand Based Zoom Speed Adjustment ON OFF Specifying Zoom Demand Specifications Items labeled Top can also be modified from t...

Страница 137: ...oom CurveMode Tracking Zoom OFF Movement CurveMode Tracking Zoom ON Movement CurveMode I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press Tracking is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Screen Zoom Screen Options D OFF ON Description Zo...

Страница 138: ... Start D99 91 Movement Zoom Stop Start 97 91 OFF Movement CurveMode Zoom I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press twice Movement is underlined Press The display switches to the Movement screen Press The display reverts to Screen A Press Start is underlined The previous or default value is highlighted Press or Press left o...

Страница 139: ...g OFF Movement Zoom CurveMode Tracking OFF Movement CurveMode Zoom I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press twice Movement is underlined Press The display switches to the Movement screen Press The display reverts to Screen A Press twice Start is underlined The previous or default value is highlighted Press or Press left o...

Страница 140: ... Zoom Stop Start 99 91 Movement Zoom End Stop D99 91 Movement Zoom End Stop 97 91 I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press twice Movement is underlined Press The display switches to the Movement screen Press The display reverts to Screen A Press three times End is underlined The previous or default value is highlighted Pr...

Страница 141: ... settings apply For instructions see 4 1 3 Switching Users or 4 2 1 User Screen Settings Switching Users Press once and four times The display switches to the Zoom screen Press or Press left or right until you reach the desired function Press three times CurveMode is underlined Press Seesaw is underlined The previous or default value is highlighted Press The display switches to the CurveMode scree...

Страница 142: ... Zoom Demand Seesaw 5 7 Tracking OFF Movement Zoom CurveMode I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press three times CurveMode is underlined Press The display switches to the CurveMode screen Press The display reverts to Screen A Press twice Demand is underlined The previous or default value is highlighted Press or Press lef...

Страница 143: ...j Zoom Min Max D99 01 SpeedAdj Zoom Min Max 97 01 Tracking OFF Movement Zoom CurveMode I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press four times SpeedAdj is underlined Press The display switches to the SpeedAdj screen Press The display reverts to Screen A Press Max is underlined The previous or default value is highlighted Pres...

Страница 144: ...peedAdj Control Sped Zoom SpeedAdj Zoom Min Max 99 D01 SpeedAdj Zoom Min Max 03 99 I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press four times SpeedAdj is underlined Press The display switches to the SpeedAdj screen Press The display reverts to Screen A Press twice Min is underlined The previous or default value is highlighted Pr...

Страница 145: ...ed SpeedAdj Control VR Dem ON Zoom Posi I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press once and four times The display switches to the Zoom screen Press five times Control is underlined The previous or default function is highlighted Press or Press left or right to switch the function to Sped or Posi Initial Top Screen Zoom Screen Options D Sped Posi Description Speed servo Position servo D D...

Страница 146: ...witching Users Tracking OFF Movement Zoom CurveMode Control VR Dem Zoom ON Sped Control VR Dem Zoom OFF Sped I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H SpeedAdj SpeedAdj Press once and four times The display switches to the Zoom screen Press six times VR Dem is underlined The previous or default function is highlighted Press or Press left or right to switch the function ON or OFF Initial Top Sc...

Страница 147: ...E145 4 Operation in Full Mode 4 2 6 Focus Screen Settings The following setting items can be configured on the Focus screen Specifying Focus Demand Responsiveness ...

Страница 148: ...eMode is underlined Press The display switches to the CurveMode screen Press The display reverts to Screen A Press ADemand is underlined The previous or default value is highlighted Press or Press left or right until you reach the desired function Initial Top Screen Focus Screen Screen A CurveMode Screen Options 1 to 9 Description Large curve Small curve Default value 5 MENU 3 Focus or 1 2 3 4 5 6...

Страница 149: ...r information on specifying the 3D function see the instruction manual of the BC 100 3D cable Specifying Encoder Output Serial Communication with Camera ON OFF Specifying the Input Route for Command Signals from the Camera Specifying the Technology Distance Unit Checking Lens Drive Unit Communication Configuring Settings in System Mode Used by Canon Service Technicians Only ...

Страница 150: ...Serial Numbers Check lens and drive unit serial numbers as needed Press once and twice The display switches to the Info screen Press S N is underlined Press The lens and drive unit serial numbers are displayed Initial Top Screen Info Screen MENU 2 Info 1 1 2 3 Note The serial number of the lens is not displayed when no power is being supplied to the lens from the camera mount ...

Страница 151: ... Fr1P Basic Trk OFF I Tq H Info Info CamSeri ON Encoder IND ON Info CamSeri ON Encoder Encoder OFF S N 3D OFF 3D OFF 3D OFF Press once and twice The display switches to the Info screen Press three times Encoder is underlined Press or Press left or right to switch the function ON or OFF Initial Top Screen Info Screen Options D OFF ON Description Output disabled Output enabled D Default value MENU 2...

Страница 152: ...rict the interface to analog control set it to OFF Info CamSeri Encoder OFF I Fprior I Fprior Mount Mount ON I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Info Encoder OFF S N Info CamSeri Encoder OFF OFF OFF 3D Press once and twice The display switches to the Info screen Press four times CamSeri is underlined Press or Press left or right to switch the function ON or OFF Initial Top Screen Info Sc...

Страница 153: ... the mount are given priority However the command signals via the 12 pin cable are received automatically if no command signals are input via the mount When the Cable setting is selected only command signals received via the 12 pin cable are used Press once and twice The display switches to the Info screen Press five times I Fprior is underlined Press or Press left or right to switch the function ...

Страница 154: ...tion sent for the actual subject distance hyperfocal distance subject distance at close range and infinity and entrance pupil position is expressed in the specified unit Note Any distance unit set on the camera takes precedence Press once and twice The display switches to the Info screen Press six times i is underlined Press Press Units is underlined The previous or default value is highlighted Pr...

Страница 155: ...munication between the lens and drive unit as follows Press once and twice The display switches to the Info screen Press seven times State is underlined Press Press Lens is underlined Press This screen indicates normal communication If Non connected is displayed contact Canon or your dealer MENU 2 Info 7 1 2 3 4 5 Initial Top Screen Info Screen Note Non connected is displayed when no power is bein...

Страница 156: ...E154 4 Operation in Full Mode 4 2 8 Fol Screen Settings The following setting items can be configured on the Fol screen Viewing Lens Follow Settings Iris Zoom Focus ...

Страница 157: ... 0 1000 Fol Iris Zoom Focus 0000 1000 0000 1 I Gain Adj MENU 1 A Fr1P Basic Trk OFF I Tq H Press and then The display switches to the Fol screen showing relative follow iris zoom and focus values Initial Top Screen Fol Screen MENU Fol 1 1 Note As long as the Fol screen is shown the display will not turn off automatically after 2 minutes if left idle To turn off the display press the Display switch...

Страница 158: ...1P Fr1F Fr2P Fr2F Sped Shtl NON I Tq H H L A 1 Shtl VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl NON V VTR VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl A 2 Fr1P VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl NON R RET VTR RET Fr1P Fr1F Fr2P Fr2F Sped Shtl Z M To 3 on the next page Zoom Zoom Iris AM Norm Norm Reve Auto Manu Escape Operation Jump to user 0 setting status Hold down both the Display switch and Set key for a...

Страница 159: ...800 ZMovement Start 99 00 99 Stop 91 00 99 Iris Go Top I Gain Auto 50 01 99 2 Remote 90 01 99 Torque High High Low Comp ON ON OFF Close OFF OFF ON Controller OFF OFF ON Zoom Tracking OFF OFF ON Movement Start 99 00 99 Stop 91 00 99 End 99 00 99 CurveMode Seesaw 5 1 9 3 Demand 5 1 9 SpeedAdj Max 99 Min value 99 Min 01 01 Max value Control Sped Sped Posi VR Dem ON ON OFF Focus CurveMode ADemand 5 1 ...

Страница 160: ...Memo ...

Страница 161: ...Operation in Analog Mode 5 INFORMATION DISPLAY ...

Страница 162: ...ccess the Top screen press the Display switch A total of 3 items can be configured on the Top screen in Analog mode The first screen displayed is referred to as the Initial Top screen Status of some items can be checked simply by accessing this screen MENU IG 50 Basic Initial Top Screen in Analog Mode ...

Страница 163: ...zoom switch AUX and MEMO switches are disabled To set auto iris gain adjustment use either display or trimmer operations Shuttle shot frame preset speed preset and zoom tracking are not available Switching from Basic to Analog Mode Mode User Basic Access ResetAll B Unlock Mode User Basic Access ResetAll B Unlock User Access Mode A Unlock Analog Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Ad...

Страница 164: ...ENU Basic IG 50 1 3 2 1 4 2 3 5 7 6 8 9 MENU Menu screen See 5 2 Configuration from the Menu Screen 1 4 2 3 5 7 6 8 9 IG Auto iris gain Adjust the auto iris gain value as needed See 5 1 3 Specifying Auto Iris Gain 1 4 2 3 5 7 6 8 Basic Switching to Basic Mode Switch to Basic mode as needed See 5 1 4 Switching to Basic Mode Initial Top Screen 1 Inside Items that show the current setting status Exam...

Страница 165: ...but corresponds to the value determined with the iris gain adjustment trimmer MENU IG 50 or IG 50 IG 50 IG 51 IG 51 MENU IG 50 Basic IG 50 MENU MENU Basic IG 51 MENU MENU Basic Note Do the following when adjusting gain while checking iris operation Confirm that the drive unit A M switch is set to Auto mode Set the camera iris mode to Auto Note As you look at the lens iris ring set it to the positi...

Страница 166: ...d Switching from Analog to Basic Mode MENU IG 50 Basic MENU MENU Basic IG 50 Trk OFF Shtl A 1 A 2 MENU IG 50 A Fr1P Fr1P I Tq H Adj Initial Top Screen in Analog Mode Initial Top Screen in Basic Mode MENU Basic Press The mode switches and the Initial Top screen in Basic mode is displayed Press Basic is highlighted 1 2 ...

Страница 167: ...to access the User screen See the following figure There is no single Menu screen Instead screens accessed by selecting MENU and pressing the Set key are collectively referred to as the Menu screen Go Top Back Set Set 1 Mode User Analog Access A Unlock MENU IG 50 Basic 1 User Screen 5 2 1 To the next screen clockwise To the next screen counterclockwise To the Go Top screen To the User screen To th...

Страница 168: ...peration in Analog Mode 5 2 1 User Screen Settings The following setting items can be configured on the User screen Switching Modes Locking Functions Mode User Analog Access A Unlock User Screen in Analog Mode ...

Страница 169: ...alog Access A Unlock Mode User Analog Access A Unlock Mode User Basic Access A Unlock Initial Top Screen User Screen Press The display switches to the User screen Press Mode is underlined The previous mode is highlighted 1 2 3 Press or Press left or right until you reach the desired mode Options D Basic Full Analog Save Settings Basic Mode Full Mode Analog Mode D Default value MENU User A or ...

Страница 170: ...nctions are locked they are locked for all users Two display operations are available in Analog mode auto iris gain adjustment and user switching However you cannot switch users when functions are locked because this function is also locked Unlocking functions requires the password used to lock them Press The display switches to the User screen Press twice The previous or default value is highligh...

Страница 171: ...age Characters supported in passwords Options D _ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z 0 1 2 3 4 5 6 7 8 9 Max Digits 8 D Default value _ Space Options D Unlock Lock D Default value 2 Entering Passwords DISPLAY 4 5 Note Passwords No master password is used on this model The password you enter each time to lock settings is the passw...

Страница 172: ...the User screen Press twice The previous or default value is highlighted Enter the password and press Entering Passwords Press up down to find characters and left right to move the cursor or make corrections Be careful not to press the Set key until you are finished entering the password Press Press and then The settings are now unlocked Options D Unlock Lock D Default value 2 Entering Passwords D...

Страница 173: ...og Mode 5 3 List of Settings Default Value Options Page Top MENU To 1 on the next page IG 50 01 99 Basic Basic Escape Operation Jump to user 0 setting status Hold down both the Display switch and Set key for at least 2 seconds ...

Страница 174: ...72 5 Operation in Analog Mode Default Value Options Page MENU User 1 Mode Basic Basic Analog Full Access Unlock Unlock Lock Go Top Set key operation Right key operation Up key operation Left key operation ...

Страница 175: ...Memo ...

Страница 176: ...CANON INC 30 2 Shimomaruko 3 chome Ohta ku Tokyo 146 8501 Japan BT1 D008 A ENG 2022 09 CANON INC ...

Отзывы: