Chapter 3
3-5
3) Remove the joint shaft [1], and free the extension
delivery unit [2] from the right door.
F-3-16
4) Disconnect the connector [1], and remove the reuse
band [2]; then, remove the 2 screws (M4x8; RS
tightening).
F-3-17
5) While freeing the hinge assembly [2], detach the
right door.
F-3-18
Attaching the Right Door
1) Match the hinge [1] found at the bottom of the right
door against the lug.
2) Engage the hinge [2] found on the top of the right
door with the hook found on the side plate.
F-3-19
When tightening the 2 screws used to fix the hinge in
place, be sure to close the right door first.
3.2.1.4
Removing the
Extension Delivery Kit
0007-6156
1) Free the harness [2] front the cable clamp [3], and
remove the 2 re-use bands [4].
2) Disconnect the connector [1] from the terminal of
the host machine.
F-3-20
3) Open the extension delivery kit [1].
4) Remove the 2 screws [3].