background image

ENG-10

Using the Image Stabilizer

When you look through the binoculars, the image may be shaking and difficult 
to see since your hands are holding the binoculars. In such a case, the Image 
Stabilizer can help steady the image.
The Image Stabilizer can be operated using the following methods.

Five-minute operation and 

stopping operation

• Press the Image Stabilizer button and 

quickly let it go, and the Image Stabilizer 

will operate continuously for five 

minutes.

• To stop the Image Stabilizer, press and 

release the Image Stabilizer button 

again.

Starting and stopping Image Stabilizer operation while 

holding down the button

• The Image Stabilizer will operate while holding down the Image Stabilizer 

button.

• The Image Stabilizer will stop once you let go of the button.

 

z

When the Image Stabilizer button is operating, the lamp turns on.

 

z

If the lamp does not turn on, replace the batteries with new ones.

 

z

The Image Stabilizer may not be able to compensate when the user's 

body is being deeply shaken, subjected to vibration, or when the user's 

hands are shaking too much.

 

z

The Image Stabilizer will stop once the batteries run out.

 

z

Even without batteries loaded, the binoculars can still be used as is.

Содержание 10x20 IS

Страница 1: ...Instructions ENG ...

Страница 2: ... at anytime z z IS stands for Image Stabilizer Symbols Warning to prevent malfunction or damage to the binoculars Supplementary hints for using the binoculars Accessories The binoculars come with the following accessories Case 1 Strap 1 Eyepiece lens caps 2 CR123A Lithium battery 1 Contents Precautions for Use ENG 2 4 Nomenclature ENG 5 Using the Lens Caps ENG 6 Installing the Strap ENG 6 Loading ...

Страница 3: ...ning regarding the batteries Details pertaining to risks that may result in death or serious injury z z Store the batteries used with this product out of the reach of infants Also avoid replacing the batteries where the procedure can be observed by infants Swallowing the batteries will result in a chemical reaction occurring within the body and is extremely dangerous Seek the advice of a doctor im...

Страница 4: ... z z Do not store the product in very hot or cold places The product itself will heat or cool possibly causing burns or other injury when touched z z When used for a prolonged period or when used repeatedly the rubber eyecups may irritate the skin around the eyes If you suspect that this may have occurred please see a physician Caution regarding the batteries Details pertaining to risks that may r...

Страница 5: ...terproof Avoid exposing the binoculars to rain or water spray If the binoculars come into contact with water dry them with a dry clean cloth If dirt dust or salt adheres to them wipe them well with a clean well wrung wet cloth If water gets onto or into the binoculars or you think dirt dust salt etc may have gotten in promptly take the binoculars to a service center z z Do not use any organic solv...

Страница 6: ... 10x20 IS shown in the illustrations Image Stabilizer button Objective lenses Lamp Dioptric correction scale Dioptric correction ring Battery chamber cover Strap mount Focusing knob Eyecup Eyepiece lenses Eyepiece lens caps ...

Страница 7: ...ng the binoculars Installing the Strap 1 Fasten the strap z z Place one end of the strap through the strap mount and then through the clasp which is attached to the strap from underneath 2 Check the clasp z z Make sure that the strap does not loosen at the clasp when you pull it z z When using the binoculars check the condition of the strap make sure that the strap is securely installed that it is...

Страница 8: ...the correct orientation as indicated at the bottom of the battery chamber z z When loading the battery insert the pole against the spring electrode inside the battery chamber and then push it in as far as it will go Surface fasteners 3 Fix the battery firmly in place with the surface fasteners z z Wrap the surface fastener shown on the left in the illustration around the battery and then wrap the ...

Страница 9: ...in the pole spring electrode being bent or otherwise damaged z z When fixing the battery in place with the surface fasteners check to make sure that the surface fasteners are not loose and show no wearing damage z z Be careful not to let moisture onto the inner side of the battery chamber cover or into the chamber If there is moisture make sure to remove it and adequately dry it off before changin...

Страница 10: ...s converge z z When adjusting the width of the binoculars to suit the width between your eyes look at a distant object 3 Adjust the diopter z z Compensates for the difference in visual acuity between your left and right eyes z z First look through the left eyepiece only and adjust the focusing knob until the object looks sharp z z Then look through the right eyepiece only and look at the same obje...

Страница 11: ...lease the Image Stabilizer button again Starting and stopping Image Stabilizer operation while holding down the button The Image Stabilizer will operate while holding down the Image Stabilizer button The Image Stabilizer will stop once you let go of the button z z When the Image Stabilizer button is operating the lamp turns on z z If the lamp does not turn on replace the batteries with new ones z ...

Страница 12: ...case z z Place the binoculars in the case while allowing the strap to extend outside the case 2 Close the case flap z z After the strap has been extended close the case flap z z Check to see that the lamp is off before placing the binoculars in the case ...

Страница 13: ...ter has not been properly set Adjust the diopter See step 3 on page 9 The width of the binoculars does not suit the width between your eyes Adjust the width of the binoculars See step 2 on page 9 The binoculars are not properly focused Focus the binoculars See step 4 on page 9 The Image Stabilizer does not operate There are no batteries loaded Load batteries having enough power See page 7 Loading ...

Страница 14: ...m Focusing distance range Approx 2 m 6 6 ft infinity Interpupillary adjustment range 56 72 mm 2 2 2 8 in Image Stabilizer system Optical correction with lens shift Correction angle 0 9 Battery check Lamp LED turns on Power 1 CR123A Lithium battery Operating environment Temperature 10 C to 40 C 14 F to 104 F Humidity 90 Dimensions W x L x H Approx 118 x 142 x 69 mm 4 6 x 5 6 x 2 7 in Weight Excludi...

Страница 15: ...rent from that to which the receiver is conected Consult the dealer or an experienced radio TV technician for help CANON U S A Inc One Canon Park Melville NY 11747 U S A Tel No 1 800 OK CANON 1 800 652 2666 CAN ICES 3 B NMB 3 B Only for European Union and EEA Norway Iceland and Liechtenstein These symbols indicate that this product is not to be disposed of with your household waste according to th...

Страница 16: ...CT1 B082 A 0619Ni CANON INC 2019 ...

Отзывы: