Installation
9145E Ethernet Network Interface Device User Manual
Connecting the Electrical Power
36
11. Insert the terminal block into the socket. The 9145E will power up.
Figure 3-11 Connect D.C. Power
NOTE:Accidently reversing polarity will NOT damage the power supply or
source.
3.5.2.1 Fuses
The 9145E is equipped with an internal 3A slow blow fuse. Although not required, an external
fuse can be used to isolate the 9145E in a shared fuse distribution panel.
Based on the 9145E inrush power characteristics, the minimum fuse ratings are as follows:
•
Slow Blow Fusing: 3A slow blow fuse for all DC input voltage (48VDC or 24VDC)
•
Fast Blow Fusing: 5A fast acting fuse for DC input voltages (48VDC or 24VDC)
For additional information on the inrush power characteristics of the 9145E, contact the Canoga
Perkins Technical Support Hotline at 1-800-360-6642.