EdgeAccess Universal Chassis System
UCS 1000
2-2
4. To connect Earth Ground to the bonding lug on the rear of the chassis, near the bottom, move the
chassis adjacent to the installation area, then plug the Earth Ground wire into the bonding lug.
5. You can mount the chassis in a standard 19-inch relay rack, in a 23-inch rack using optional
brackets, or place it on a flat, secure surface.
•
To mount the chassis in a 19-inch rack, position the chassis in the rack, then attach the
bracket to the rack with four screws.
•
To mount the chassis in a 23-inch rack, replace the standard bracket with the optional
mounting bracket, then attach that bracket to the rack with four screws; see Figure 3.
•
To place the chassis on a flat, secure surface, turn the chassis upside down, mount the self-
adhesive feet at the four corners of the bottom for the chassis, then turn the chassis right-side
up. Keep a space around the chassis to allow airflow.
Three screws mount the
bracket on the chassis
Figure 3. Mounting Bracket on Chassis
If the system includes two or more chassis that are connected through a CIM in each chassis, each
chassis must be set to a unique ID number.
6. Locate SW1 inside the chassis at the upper left of the backplane; see Figure 4.
Caution:
Make sure that the chassis power is off or disconnected. Use a non-conductive device
to set SW1.
7. Set SW1 to the ID number for this chassis according to the information in Table 2.