Canoga Perkins EdgeAccess 9135 SNMP Скачать руководство пользователя страница 51

EdgeAccess Universal Chassis System

Model 9135 10/100/1000

A-1

Appendix A
Warranty

Limited Lifetime Warranty

Effective July 1, 2005 and After

,

 

Canoga Perkins warrants that, at the time of sale, and, for its lifetime, with

certain exceptions noted below, every Canoga Perkins' labeled product purchased will be free from defects in
material and workmanship for its lifetime, if properly installed and used in conformity to Canoga Perkins'
published specifications.  This warranty covers the original user only and is not transferable.  For the purposes
of this Warranty, "lifetime" is defined as the serviceable life of the product (a minimum of 5 years) or any
longer period during which replacement spare parts are available.  Subject to the conditions and limitations set
forth below, Canoga Perkins will, at its option, either repair or replace any part of its product(s) that prove
defective by reason of improper workmanship or materials. The warranty period for power supplies, fans and
optics is five (5) years.  Consumables such as filters are covered for one year. Software is warranted for 90
days. Hardened Media Converter (HS) products are covered for three (3) years.

This warranty does not cover any damage to products that have been subjected to lightning or other Acts of
Nature, misuse, neglect, accident, damage, improper installation, or maintenance, including over-voltage
failures caused by use outside of the product's specified rating, normal wear and tear of mechanical components,
or alteration or repair by anyone other than Canoga Perkins or its authorized representative. If the user is unsure
about the proper means of installing or using the equipment, contact Canoga Perkins' free technical support
services. Customer must notify Canoga Perkins promptly in writing of any claim based on warranty. Canoga
Perkins is not liable for, and does not cover under warranty, any costs associated with servicing and/or the
installation of its products or for any inspection, packing or labor costs in connection with return of goods. In
the event Canoga Perkins breaches its obligation of warranty, customer's sole and exclusive remedy is limited to
replacement, repair, or credit of the purchase price, at Canoga Perkins' option.  Under no circumstance will
Canoga Perkins be liable for consequential or incidental damages or loss of profits.

Warranty Registration

To establish original ownership and to record purchase date, please complete the warranty on-line form on our
product registration page. URL: 

www.canoga.com/warranty

Optional Service Programs

Canoga Perkins offers several optional Service Programs.  Please call Canoga Perkins Sales Department (818-
718-6300) or see our web site (www.canoga.com) for details.

CUSTOMER SERVICE DEPARTMENT REPAIR WARRANTY

Repairs performed by the Canoga Perkins Customer Service Department will be free from defects in material
and workmanship for a period of ninety (90) DAYS from the date the repaired product is shipped, or until the
expiration of the original factory warranty, whichever is longer.

Содержание EdgeAccess 9135 SNMP

Страница 1: ...Model 9135 SNMP Managed 10 100 1000 Ethernet Switch User Manual...

Страница 2: ......

Страница 3: ...t de 1300nm 1600nm L utilisation d instruments optiques par exemple un collimateur optique avec cet quipement peut s av rer dangereuse pour les yeux Proc der des contr les des ajustements ou toute pro...

Страница 4: ...change the specifications of its products at any time without prior notification Every effort has been made to keep the information in this document current and accurate as of the date of publication...

Страница 5: ...5 1 Global Spanning Tree Parameters 3 11 3 5 2 Port Spanning Tree Parameters 3 12 3 5 3 Spanning Tree Report 3 14 3 6 Port Information 3 15 3 7 Reports 3 17 3 7 1 Description Report Screen 3 17 3 7 2...

Страница 6: ...u 3 8 Figure 12 Passwords Menu 3 9 Figure 13 Switch Configuration Menu 3 10 Figure 14 Typical Spanning Tree Application 3 11 Figure 15 Spanning Tree Parameters Menu 3 11 Figure 16 Global Spanning Tree...

Страница 7: ...in Menu Options 3 3 Table 7 System Menu Options 3 4 Table 8 IP Settings Menu Options 3 5 Table 9 IP Address and Subnet Mask 3 5 Table 10 SLIP Port Settings Options 3 8 Table 11 Password Access Levels...

Страница 8: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 vi...

Страница 9: ...ules The hot swappable interface modules provide these options 850 nm multimode 1310 nm multimode 1310 nm single mode or 1550 nm single mode ST SC FC PC or duplex SC connectors The 9135 supports IEEE...

Страница 10: ...ement Alarm relay contacts that can transmit these fault conditions for each port Loss of link integrity Remote fault Power failure SNMP Hardware and software watchdog for automatic recovery Serial EI...

Страница 11: ...oga Perkins products as with all electronic devices with static sensitive components 1 Unpack the 9135 Keep the shipping container until the unit is installed and fully operational In the unlikely eve...

Страница 12: ...00 Base Modules Fiber Optic Interface Table 2 SW1 Settings 100 Base Modules Fiber Optic Interface Switch Name On Off 1 1 FDX Full duplex Half duplex 1 2 LLF Enable LLF Disable LLF 1 3 LLE Enable LLE D...

Страница 13: ...the 48VDC power supply For a 48VDC source connect the grounding strap between the Chassis Ground and the VDC terminals For a 48VDC source connect the grounding strap between the Chassis Ground and th...

Страница 14: ...primary secondary to secondary and Tx to Rx Rx to Tx orientation Caution To protect the Ethernet port from an intrabuilding lightning surge use a properly grounded shielded cable 13 Plug the Ethernet...

Страница 15: ...emote fault detected FX interface only Fdx Off Operating as half duplex Green Operating as full duplex Par Partition Off Operating normally Red Receiving too much data Aut Auto negotiation Off Auto ne...

Страница 16: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 2 6...

Страница 17: ...click Start then highlight Programs Accessories the HyperTerminal Folder and then click HyperTerminal 5 At the Connection Description dialog select an icon enter a name for the connection to the syste...

Страница 18: ...for that item Tab Press Tab to move the highlight to the next column to the right Enter Press Enter to select the highlighted option for a menu item Escape Press Esc to return to the previous screen 3...

Страница 19: ...nus for Spanning Tree parameters 3 Port Information Status and statistics for ports 4 Reports System description and logs 5 Diagnostics Ping 6 Restore Defaults Restores all factory defaults except IP...

Страница 20: ...P Settings menu to view and update the IP parameters and configuration for the 9135 To access the IP Settings menu see Figure 9 and Table 8 and follow these steps 1 From the System Menu type 2 IP Sett...

Страница 21: ...firmware upgrades or disable downloads 6 Enable BOOTP Mode Set the 9135 to broadcast BOOTP requests to the local network until it receives an IP address form the server or you press Esc at the first s...

Страница 22: ...ions for Telnet SNMP or both and then press Enter to confirm d Press Tab then press Space to cycle through the SNMP Access level options for read write and trap and then press Enter to confirm e Press...

Страница 23: ...erial Line Internet Protocol SLIP mode runs point to point and does not display messages on screen Only those IP packets addressed to the SLIP IP address receive a response The SLIP IP address must be...

Страница 24: ...d Enter a password for SLIP mode up to 15 characters 6 SLIP IP Address Enter the IP address for SLIP mode 7 SLIP Subnet Mask Enter the Subnet Mask for SLIP mode 8 SLIP Port Setup Opens the SLIP Port S...

Страница 25: ...g The Manager and User levels are more limited Password level assignments are fixed Table 11 lists the minimum access level for each menu item Table 11 Password Access Levels by Menu Menu and Selectio...

Страница 26: ...etup Menu Start Pinging User Baud Rate Supervisor Parity Supervisor Stop Bits Supervisor Flow Control Supervisor 3 5 Switch Configuration and Spanning Tree The Switch Configuration menu offers one opt...

Страница 27: ...ing Tree Parameters 3 Spanning Tree Report 4 Main Menu Figure 15 Spanning Tree Parameters Menu Table 12 Spanning Tree Parameters Options Menu Item Description 1 Global Spanning Tree Parameters Set the...

Страница 28: ...ighest priority 3 Hello Time sec Set how often the 9135 sends BPDUs if this 9135 is the Spanning Tree root 4 Forward Delay sec Set the time between port state transitions from Learning to Forward if t...

Страница 29: ...ork adds the address data to the local database sends BPDUs and transmits received BPDUs responds to network management messages the port is learning the network topology Forwarding Forwards all data...

Страница 30: ...ier of the bridge that appears to this 9135 to be the root Topology Change Shows that the network topology changed Root Cost Shows the cost of the path to the root from the bridge When the bridge is t...

Страница 31: ...follow these steps 1 From the Main menu type 3 Port Information and press Enter 2 From the Port Information screen type 1 2 or 3 and press Enter Ports 9100 330 9100 330 ______________________________...

Страница 32: ...ent 5844443 Frames 64 Bytes 68656 Bytes Received 0 Frames 65 127 Bytes 0 Frames Sent 63023 Frames 128 255 Bytes 0 Frames Received 0 Frames 256 511 Bytes 0 Multicast Received 0 Frames 256 511 Bytes 0 B...

Страница 33: ...ports menu appears 2 From the Reports Menu type 1 Description and press Enter The Description screen appears see Figure Description Device Type 9135 10 100 100 Switch Software Revision Flash1 1 00 Sof...

Страница 34: ...ors can configure the traps on the Host Table SNMP Settings for details see Section 3 4 2 The 9135 reports these traps Cold Start Warm Start Link Up Link Down Authentication Fail EGP Neighbor Loss Rem...

Страница 35: ...gnal to a specific remote unit to verify that it can receive the signal and reply See Figure 27 Diagnostics 1 Ping 2 Main Menu Figure 27 Diagnostics Menu To access the Ping menu follow these steps 1 F...

Страница 36: ...estore Defaults and press Enter See Figures 7 and 29 2 At the prompt type Y and press Enter The defaults are restored Restore Defaults 1 System 2 Switch Configuration 3 Port Information 4 Reports Rest...

Страница 37: ...The Description screen appears 3 Record the version numbers for Software Revision Flash1 and Software Revision Flash2 4 To check if a newer version of the software is available access www canoga com C...

Страница 38: ...er version than is available on your 9135 use the FTP Client on your PC to download the upgrade file and to the 9135 Start the FTP Client to begin the upgrade then enter data for the download Note The...

Страница 39: ...ete a successful message appears At the prompt enter quit to close the FTP connection 14 To activate the new software revision reset the 9135 then return to the Description screen to verify that the n...

Страница 40: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 3 24...

Страница 41: ...is enabled SLIP IP Address for 9135 SLIP Subnet Mask for 9135 SLIP Port Setup 9600 N 8 1 The 9135 is ready for management by SLIP connection 4 2 Setting up the SLIP Connection on the PC Install the mo...

Страница 42: ...Pop up a terminal window then click OK The PC is ready to make the SLIP connection 4 3 Launching a SLIP Connection Follow these steps to launch the SLIP connection to the 9135 1 On the desktop double...

Страница 43: ...unters Terminal Port EIA 232 DTE DE 9 female connector VT100 compatible SLIP Modem Port EIA 232 DCE DE 9 male connector Modem control or SLIP Software Download TFTP Network IP Configuration BOOTP or U...

Страница 44: ...5 2 5 2 9135 Ports and Pinouts Table 17 Terminal Port Female DE 9 Pin Signal 1 4 8 9 Not Used 2 RXD In 3 TXD Out 5 Common 7 Ground Table 18 SLIP Port Male DE 9 Pin Signal 1 DCD In 2 RXD In 3 TXD Out...

Страница 45: ...0BASE TX UTP Copper Field Interchangeable Interfaces 9100 330 10 100BASE TX HW or SW Configurable UTP Copper Interface 10BASE FL Fiber Optic Field Interchangeable Interfaces 9100 431 10BASE FL 850 nm...

Страница 46: ...plex SC connector 26 dB w 8 or 10 125 Fiber 1000Base SX Fiber Optic Field Interchangeable Interface 9100 657 1000BASE SX 850 nm MM with SC connectors 5 5 dB loss budget 1000BASE LX LD EX LH Fiber Opti...

Страница 47: ...m minimum Transmit Launch Power 0 dBm maximum 4 dBm minimum Overdrive 10 dBm Loss Budget 25 dB minimum Optical Connector ST or FC PC 10 BASE FL SM 26 dB Emitter Type Laser diode Wavelength 1550 nm nom...

Страница 48: ...um Transmit Launch Power 0 dBm maximum 4 dBm minimum Overdrive 8 dBm Loss Budget 26 dB minimum Optical Connector Duplex SC or ST 100 BASE FX SM 26 dB 1550 nm Emitter Type Laser diode Wavelength 1550 n...

Страница 49: ...plex SC Gigabit Single Mode SM 1310 nm LD DFB Emitter Type Laser Diode Wavelength 1310 nm nominal Receive Sensitivity 21 0 dBm Maximum Transmit Power 2 0 dBm maximum 0 0 dBm minimum Overdrive 3 dBm ma...

Страница 50: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 5 8...

Страница 51: ...specified rating normal wear and tear of mechanical components or alteration or repair by anyone other than Canoga Perkins or its authorized representative If the user is unsure about the proper means...

Страница 52: ...ON CANOGA PERKINS BEHALF Return Policy Customer must obtain an RMA Return Material Authorization number from the Canoga Perkins Customer Service Department before returning a product for service or r...

Страница 53: ...quipment DTR Data Terminal Ready Fdx Full duplex LLE Link Loss Echo LLF Link Loss Forwarding Lnk Link NC Normally Closed relays and switches NO Normally Open relays and switches PING Packet Internet G...

Страница 54: ...CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth California 91311 6008 USA Phone 818 718 6300 FAX 818 718 6312 Web Site www canoga com Email fiber canoga com...

Отзывы: