23
134942 Rev 1.
English
Trigger / Jekyll
- Owners Manual Supplement
To set air pressure:
1. Set handlebar remote to Flow
mode: press the black handlebar
remote button (a) so that the remote
handlebar control is in the position
shown below.
(a)
(b)
2. Remove the Schrader valve cap (1)
and pressurize the shock with a shock
pump.
3. Remove the shock pump.
4. Cycle the shock 10 times to allow the
positive and negative air pressures to
equalize.
NOTE: Air pressure measured at the
pump will decrease after air has
transferred from positive to negative
chambers.
5. Remove the shock pump from the
shock valve.
6. Check sag to confirm your shock
setup. Recommended seated sag
with full riding gear is 30%
7. If there is too much sag, add air
pressure in 10 psi increments until
correct sag is achieved. If there is
too little sag, reduce air pressure in
10 psi increments until correct sag is
achieved.
8. Install the Schrader valve cap onto
the air valve.
9. Turn the red rebound adjuster clock
-
wise towards “slow” until it stops.
a. Float X - Insert a 2mm hex wrench
into a cutout in the red rebound
knob located near the eyelet on the
frame side of the shock. Use the
wrench to turn the knob towards
“slow” until it stops.
b. Float DPS - Turn the red rebound
knob located under the blue com
-
pression adjustment lever on the
frame side of the shock clockwise
towards “slow” until it stops.
10. Turn the red rebound knob
counter-clockwise towards “fast”,
counting each detent click until you
reach the recommended number of
clicks based on the table below.
Содержание Jekyll 2019
Страница 35: ......