Prior to installation, ensure that the local distribution conditions (nature of the gas and
gas pressure) and the adjustment conditions are compatible. The adjustment
conditions for this appliance are stated on the data badge which is fitted behind the
bottom of the main oven door seal.
This appliance is not designed to be connected to a combustion products
evacuation device. It must be installed and connected in accordance with current
installation regulations. Particular attention should be given to the relevant require-
ments regarding ventilation.
MODEL NUMBERS 10211G, 10216G & 10212G Mk2
Category I
2H
(GB. IE)
These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY and can not be
used on any other gas.
LOCATION
The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in
a room containing a bath or shower. The cooker must not be installed in a bed-sitting
room of less than 20m
3
.
PROVISION FOR VENTILATION
The room containing the cooker should have an air supply in accordance with
BS 5440: Part 2.
The room must have an openable window or equivalent; some rooms may also require
a permanent vent. If the room has a volume between 5 and 10m
3
, it will require an air
vent of 50cm
2
effective area unless it has a door which opens directly to outside. If the
room has a volume of less than 5m
3
, it will require an air vent of 100cm
2
effective area.
If there are other fuel burning appliances in the same room, BS 5440 part 2 should be
consulted to determine air vent requirements.
28
INSTALLATION INSTRUCTIONS
Содержание WINCHESTER Mk2
Страница 35: ......