INSTALLATION INSTRUCTIONS
23
CONVERSION FOR USE ON BUTANE OR PROPANE
Each hob burner requires the injector to be replaced and each burner gas tap to have
the by-pass screw adjusted according to the following procedure:
1.
Lift off the burner cap and the burner body and place it to one side.
2.
Remove the injector, located centrally in the burner base, with a suitable box
spanner and discard.
3.
Replace the injector with the appropriate replacement (see Table on page 22).
4.
Repeat for each burner.
5.
Replace the burner bodies and caps, taking care that they are positioned
correctly.
6.
Remove the tap knob and skirt from the lefthand hotplate tap. Insert a narrow flat
screwdriver through the hole in the fascia and the rear fascia mounting panel on
the lefthand side of the tap spindle. Locate the head of the screwdriver into the
slot on the by-pass screw and turn fully clockwise. Remove the screwdriver,
replace the tap knob and skirt. Repeat this procedure with the other seven
hotplate taps.
7.
Position and fix the self-adhesive LPG conversion label over the gas details on the
rating plate label.