Cannon Fitzroy / Canterbury Inbuilt | 15
log installation
1. The burner is contained within the burner chamber.
refer
FIG
17
.
2. Carefully unpack the log set. logs are numbered
as follows:
#1 - left front log
#2 - left back log
#3 - right front log
#4 - right back log
Position the four individually numbered logs in the
following order on the burner bed as shown in
FIG 18-21
. The locating pins on burner bed must engage
with corresponding holes in the individual logs.
a) Place log #1 into the 2 front left pins on the burner bed,
ensuring that the charring faces the front.
refer
FIG 18
.
b) Place log #2 onto the 2 left back pins. refer
FIG 19
.
c) Place log #3 on single right front pin, ensure fork
locates over log #2. refer
FIG 20
.
d) Place log #4 on single right back pin, ensure left side
of log rests on depression in #3 log. refer
FIG 21
.
3. refit the inner glass, making sure not to over
tighten the screws.
4. reconnect switch loom to the fascia switch set.
5. refit the front fascia.
gas ConneCtion
fig 18
fig 19
fig 21
fig 20
1. Push the gas inlet access plate into the heater cabinet
and slide the heater into the fireplace ensuring that the
gas inlet pipe is fed through the hole located at the rear
right hand side of the heater at the bottom.
refer
FIG 22
.
2. With heater in position, flanges should be hard against
masonry. Secure case flanges to the masonry.
Screw or bolt the flange through the slots provided.
Note: The appliance must be secured at the front to
a vertical face. Where this is difficult due to building
inaccuracies, limited non-combustible packing may be
used to obtain a suitable vertical surface. Method of
fixing to finished wall surface (plaster/masonary/brick)
suitable fixtures which are able to be easily removed
must be used.
3. Connect the gas supply pipe to the copper
compression fitting provided (we recommend using
a basin wrench). Push the gas inlet plate down to its
original position and seal with an appropriate easily
removable material. Do not seal with a silicone sealant
as the heater must be easily removable. Sealing is
important as it prevents any leakage of flue products
into the room. Test all connections for gas leaks.
fig 17
Burner in base of
burner chamber
69 mm
35 mm
69 mm
35 mm
fig 23
fitzroy
Canterbury
fig 24
fig 22
gas Inlet
1/2 inch compression
Solid copper
pipe to be
used only
4. Heater is not to be connected using a flexible hose.
Содержание Canterbury CANTIB-SDEEB