Canford EMO CR6 Скачать руководство пользователя страница 2

by Canford

TECHNICAL DATA SHEET

emosystems.co.uk

EMO Systems, Canford Audio Plc Crowther Road Washington,Tyne & Wear, NE38 0BW. UK

02-475 v2

the code to be a lot easier and reduces the flexibility when 
code changing. The wire coinciding with a key which does 
not appear in the set code need not be run, e.g. if the set 
code is 3642 then the wires corresponding to keys 1 & 5 
need not be used. The barrier strip numbering corresponds 
with the keypad number, i.e. barrier strip terminal 1 controls 
key 1 etc. Wires between strip numbers 7, 8 & 9 MUST be 
connected. 

4. OPERATION

On first connecting power, the system will be ‘OFF’. Upon 
entry of the correct combination (code), the code accept 
LED (marked ‘ON’) will illuminate. After approximately 10 
seconds, Output 1 and Output 1 LED on the CM6 Master 
Unit will turn on. After approximately another 10 seconds 
Output 2 and Output 2 LED will turn on. This sequence will 
continue until all connected outputs have latched on. During 
the turn-on sequence no ‘OFF’ code will be accepted.

After entry of the first correct digit of a code the rest of the 
code must be entered within 5 seconds or the code will be 
rejected. If an incorrect code is entered then wait about 10 
seconds before trying again.

Once the ‘ON’ cycle has been completed, entry of the 
correct code will start the turn-off sequence i.e. turn-on in 
reverse.

Similarly to the ‘ON’ sequence the ‘OFF’ sequence will not 
accept an ‘ON’ code until the system has completed its cycle.

If there is a loss of power the system will reset to ‘OFF’.

5 TROUBLESHOOTING

OFF or ON LED lit Wrong code or link Check code & allow 
but does not change cut on keypad PCB 20 secs between 
tries on entry of code Some items of equipment that are 
fitted with combined circuit breaker and ON/OFF switches 
do not reliably turn on remotely i.e. when the item is left 
turned on and the supply is connected. There is no solution 
to this problem apart from removing the offending circuit 
breaker; this is not recommended.

Note: These instructions apply to the installation and use of 
the CR6 remote keypad unit.

Please read the full “Instructions for Use” of the Master 
Switcher unit CM6 for full details of the complete switching 
system. 

For further information or servicing please contact your local 
EMO Dealer.

Our Policy is one of continuous development: all 
specifications and design details are subject to change 
without notice.

Отзывы: