REMOTE SWITCHER UNIT CR6 INSTRUCTIONS FOR USE

42-663

 

EMO Remote Switcher Unit CR6

WARNING: TO AVOID ELECTRICAL SHOCK READ THESE INSTRUCTIONS CAREFULLY

 

CONTENTS

1 Introduction

1.1 Safety

1.2 Description

2 Installation

2.1 Fixing

2.2 Keypad de-select

3 Wiring

4 Operation

5 Troubleshooting

These instructions apply to UK versions only.

1. INTRODUCTION

1.1. SAFETY

Mains power wiring is dangerous. A suitably qualified person 
should install the system. Reference should be made to BS 
& any other local wiring requirements Before working on 
this system or altering any of the options, isolate the Master 
Switcher CM6 and Slave Switcher CS6 units from the 
electricity supply. When the supply is hard wired turn off the 
local isolator and preferably remove the fuses. Ensure that all 
staff know that you will be working on the system. If power 
is supplied from a pluggable source, remove the plug.

This unit should be fitted in a suitable enclosure (19” rack) 
to restrict access to the wiring terminals.

1.2 DESCRIPTION

The system allows mains powered electrical equipment to 
be turned on and off in a particular sequence. Instructions 
to initiate the sequence are input via a coded keypad. The 
CR6 Remote Panel allows control from a location remote 
to the CM6 Master Unit. The CM6 Master Unit contains all 
the control electronics together with the first two sequential 
power outputs. A further 8 low voltage outputs are available 
to control CS6 Slave Units.

2. INSTALLATION

2.1 FIXING

All units are designed for mounting in a standard 19” rack.

2.2 KEYPAD DE-SELECT

When a CR6 Remote Panel is fitted to a system it is 
sometimes necessary to prevent the keypad on the master 
unit being able to operate the system. This can be achieved 
by cutting a wire link on the keypad PCB in the master unit. 
This link is situated on the LED end of the front panel PCB 
and is accessible without removing the board from the unit. 
This link only prevents the keypad from operating, it does 
not disable the LED’s so that the system status can be 
checked.

3 WIRING

To give complete control and maximum security a 9 wire cable 
is required to connect the remote panel to the master unit.

Wiring between the barrier strips is 1 to 1, 2 to 2 etc. 
Connecting cables can be any suitable low voltage type, 
e.g. burglar alarm or telephone. The use of spade crimps is 
recommended. Low voltage cables should be segregated 
from power (mains) cables.

It is possible to use the system with a reduced number of 
wires in the control cable but this does allow the ‘cracking’ of 