90
The outlet hose should disharge into a
standpipe, making sure that there are no
kinks
(fig. 6)
.
The standpipe must be at least 40 cm
above floor level and it must have an
internal diameter of at least 4 cm.
It is advisable to fit an anti-odour air trap
(fig. 6X)
. If necessary the outlet hose can
be extended up to 2,5 m, provided that it
is kept at a maximum height of 85 cm
above floor level. The extension pipe is
available from the After Sales Service
Centre.
The hose can be hooked over the side of
the sink, but it must not be immersed in
water, in order to prevent water from
being syphoned back to the machine
when this is in operation
(fig. 6Y)
.
When installing the appliance under a
worktop the hose pipe clamp must be
attached to the wall in the highest
possible position under the worktop
(fig. 6Z)
.
Check that there are no kinks in the inlet
and outlet hoses.
Connecting the outlet hose
Содержание Brava CDPMN 4S622PX/E
Страница 1: ...IT DE EN FR ...
Страница 163: ...fkhldsk ...
Страница 164: ... CDPMN S 21 09 41052009 A IDM s r l ...