SOUND SIGNALS 

 

 

 

 

 

sound 

   Freq. 

 rept. 

sound 

switches 

 

Signal 

 

     rate 

  

 

 

 

 

 

 

 

 

SW1, SW2 

special applications

 

Alternate two-tone   

800-1000  

0.5 

1 1 1 1 1   

Fire Alarms 

Alternate two-tone   

2500-3100 

0.5 

0 1 1 1 1   

Security Alarms 

Alternate fast two-tone 

800-1000  

0.25 

1 0 1 1 1   

Increased Urgency 

Alternate fast two-tone 

2500-3100 

0.25 

0 0 1 1 1   

Security Deterrent 

Alternate  two-tone   

440-554   

0.4/0.1 

1 1 0 1 1   

Evacuation Alarm, FRANCE

 

Alternate  two-tone   

430-470   

1.0 

0 1 0 1 1   

Alternate v.fast two-tone 

800-1000  

0.13 

1 0 0 1 1   

Alternate v.fast two-tone 

2500-3200 

0.07 

0 0 0 1 1 

Alternate two-tone   

440-554   

2.0 

1 1 1 0 1   

Turn-out, SWEDEN 

10 

Continuous note 

 

700 

 

0 1 1 0 1   

All Clear, SWEDEN 

11 

Continuous note 

 

1000 

 

1 0 1 0 1   

12 

Continuous note 

 

1000 

 

0 0 1 0 1   

13 

Continuous note 

 

2300 

 

1 1 0 0 1   

14 

Continuous note 

 

440 

 

0 1 0 0 1   

15 

Interrupted tone 

 

1000 

 

2.0 

1 0 0 0 1   

16 

Interrupted tone 

 

420 

 

1.25 

0 0 0 0 1   

17 

Interrupted tone 

 

1000 

 

0.5 

1 1 1 1 0   

18 

Interrupted tone 

 

2500 

 

0.25 

0 1 1 1 0   

19 

Interrupted tone 

 

2500 

 

0.5 

1 0 1 1 0   

20 

Interrupted tone 

 

700 

 

6/12 

0 0 1 1 0   

Pre-vital Message, SWEDEN

 

21 

Interrupted tone 

 

1000 

 

1.0 

1 1 0 1 0   

22 

Interrupted tone 

 

700 

 

4.0 

0 1 0 1 0   

Air-raid Alarm, SWEDEN 

23 

Interrupted tone 

 

700 

 

0.25 

1 0 0 1 0   

Local Warning, SWEDEN 

24 

Interrupted tone 

 

720 

 

0.7/0.3 

0 0 0 1 0   

Industrial Alarm, GERMANY

 

25 

Int,fast,rising volume 

1400 

 

0.25 

1 1 1 0 0   

26 

Fast siren  

 

250-1200  

0.085 

0 1 1 0 0   

27 

Rising constant,fall   

1000 

 

10/40/10  1 0 1 0 0   

Industrial Alarm, GERMANY

 

28 

ISO 8201 Evacuation 

800-1000  

as std 

0 0 1 0 0   

International Evacuation Alarm

 

29 

Fast whoop 

 

500-1000  

0.15 

1 1 0 0 0   

 

30 

Slow whoop 

 

500-1200  

4.5 

0 1 0 0 0   

Evacuation Alarm, Netherlands 

31 

Reverse sweep 

 

1200-500  

1 0 0 0 0   

Evacuation Alarm, GERMANY 

32 

Siren 

 

 

500-1200  

3.0 

0 0 0 0 0   

 

switch settings: ON=1 and OFF=0 

 

 
 
The PFEER sound signals recommended by UKOOA are:- 
 

General Alarm 

Sound Signal 15 

Interrupted tone 1000 Hz 

 

PAPA  

 

Sound Signal 31 

Reverse Sweep 1200-500 Hz 

 

Toxic Gas 

 

Sound Signal 11 

Continuous Tone 1000 Hz. 

                                                            

 

 

Содержание YA60BD

Страница 1: ...Tom Cribb Road Thamesmead London SE28 0BH Tel 44 0 20 8316 4477 or 0 20 8317 1717 Fax 44 0 20 8317 2400 Email cliffordandsnell aol com www cliffordandsnell com OPERATING AND INSTALLATION INSTRUCTIONS...

Страница 2: ...II 2 GD Ex d IIB H2 T 135 C Tamb 20 C to 60 C II 2 GD Ex d IIB H2 T 85 C Tamb 20 C to 40 C These alarms are certified in accordance with the IEC60079 0 2004 Edition 4 and IEC60079 1 2003 Edition 5 The...

Страница 3: ...pheres and have been ATEX and IECEx certified by Baseefa Ltd using EN60079 0 and EN60079 1 2004 standards Models are available for use in hazardous areas with the following classifications Group IIB a...

Страница 4: ...ble cores required by the system arrangement It is preferable that the cable and its seal be fitted at the factory or approved workshop however the method for assembling the cable and sealed component...

Страница 5: ...d stopping plug is fitted by manufacturer as standard The terminals accept wires of 2 5 mm The PCB assembly may be lifted in its slide channels to give easier access to the terminals SOUND SIGNAL SELE...

Страница 6: ...ock washers and flat washers Check that the bracket is tightly secured to the alarm enclosure The fixings for the alarm to the mounting surface are two holes 8 5mm 0 33in on 75mm 2 95in centres Suitab...

Страница 7: ...sumption of 220 mA for 24VDC 135mA for 48VDC 90 mA for 115 VAC and 45 mA for 230 VAC 24VDC 48VDC 115VAC 230VAC 5 JOULES 220mA 130mA 90mA 45mA 10 JOULES 500Ma 300mA 105mA 53mA 20 JOULES 1 1A 500mA 260m...

Страница 8: ...1 25 0 0 0 0 1 17 Interrupted tone 1000 0 5 1 1 1 1 0 18 Interrupted tone 2500 0 25 0 1 1 1 0 19 Interrupted tone 2500 0 5 1 0 1 1 0 20 Interrupted tone 700 6 12 0 0 1 1 0 Pre vital Message SWEDEN 21...

Страница 9: ...AC ALARM CONNECTION AND SOUND SIGNAL SELECTION D7292 12 Page 9...

Страница 10: ...ime with the Sounder and or Flasher only working when a ring tone is detected on the telephone input Note The Sounder will follow the ring tone whilst the the Flasher will remain flashing only switchi...

Страница 11: ...AC ALARM CONNECTION FOR 10 20J BEACONS DC ALARM CONNECTION FOR 10 20J BEACONS D7292 12 Page 11...

Страница 12: ...0v Sounder Strobe Sounder 24v dc Earth Strobe 24v dc LK2 removed link 24v dc LK1 link 0v On other side of PCB On other side of PCB Earth Connection 4 3 2 TB3 1 3 4 TB2 2 Sound Selection Pressure Unit...

Страница 13: ...e first stage sounds by supplying volts to a unit via control switch x This switch remains on and the second stage signal is controlled by switching volts to the third terminal via switch y On other s...

Страница 14: ...es for 2 nd stage of sound alarm link TB2 3 to TB1 2 Line monitoring by supply reversal Select alarm stage 1 on SW1 Select alarm stage 2 on SW2 Common supply to Sounder and Strobe On other side of PCB...