20
This water heater is equipped with a flue gas extraction flow detection system which authorises operation of the burner.
If the flow is insufficient for a prolonged period of time, the water heater shuts down for safety reasons, and indicators (
23
) 40,
60 and 80 flash.
Important:
this flue gas checking device must not be removed, or have untimely work carried out on it. If it needs to be
replaced, only original parts may be used.
16
Flue gas safety
18
Practical information
The manufacturer`s guarantee is for 12 months from the date of purchase. The guarantee is voidable if the appliance is not
installed in accordance with the recommendations made herein or in a manner not approved by the manufacturer. To assist us
in providing you with an efficient after sales service, please return the guarantee registration card enclosed with the boiler
without delay.
17
Guarantee
As with your car, your boiler will work more reliably and efficiently if regularly serviced. We recommend an annual service
check. The service history of the appliance will be marked on the logbook.
15
Maintenance
Pump anti-sticking device
When the boiler is switched on (indicator light
20
lit), the circulation pump operates for 1 minute after the water heater has
been out of operation for more than 23 hours, whatever the operation of the water heater, to prevent the pump jamming.
Precautions to take in freezing conditions
We recommend that you contact your gas fitter or After-Sales service, who will advise you of the measures to take according
to your circumstances.
Hot water circuit
The hot water circuit is drained after closing the appliance's water counter and cold water tap:
- open a hot water tap
- unscrew the cold water connection union nut
Heating circuit
Take one of the following steps:
- 1) drain the circuit of the heating appliance
- 2) protect the heating appliance with an anti-freeze product. Periodically checking the level of protection provided by this
anti-freeze is an additional guarantee requirement.
- 3) allow your appliance to run at low load by setting the room thermostat to the "anti-freeze" position (between 5 and
10°C).
- 4) leave the power to the water heater on. It is fitted with an anti-freeze device which activates the circulation pump, then
the burner.