background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

7. Frost precautions

- We advise you to contact your installer or your after-sales service to obtain details of the most suitable measures for your

installation.
Take the following steps :

- turn the heater off

- close the cold water inlet valve item 

(fig. 6, page 4)

- open a hot water tap

- unscrew the drain plug item 

(fig. 5, page 4).

22

19

To light the pilot

Turn the gas control knob in the direction of the arrow.

The click at the " " (fig. 13) generates the pilot ignition spark.

Note :The first time the pilot is lit, it may be necessary to

wait a few moments for the air to be pushed out of the pilot

circuit before the pilot lights. In this case, hold the knob for

a few moments at the  " " mark, then repeat the operation

until the pilot lights.

- When the pilot lights, hold the knob at the " " mark for a few

seconds to set the thermocouple safety device, then turn the

knob further in the direction of the arrow until it is between

" " and " " (fig. 14).

Power adjustment

- This  water  heater,  with  automatic  power  variation,  is  fitted

with a system enabling the user to limit its maximum power.

To  do  this,  turn  the  knob  until  it  is  between  the 

" " and " ".

- This appliance operates in such a way that it can be used

over a wide range of flow rates without adjusting the power.

The  hot  water  temperature  is  determined  by  the  draw-off

flow rate.

To turn off the heater

Turn the control knob back to the " " mark.

7

Fig. 13

Fig. 14

Use

6. Controls and use (continued)

8. Servicing

Annual servicing of your water heater is necessery.

Have the heater inspected by a qualified professional once a year.

Annual service contracts covering all the servicing operations on your water heater can be offered to you by service providers.

Contact your installer or our Customer Services Department.

Descaling: Only the heat exchanger should be descaled. The descaling agent must never be allowed to flow through the water

valve.

In order to ensure the safety of the consumer, we remind you that thorough rinsing is necessary after descaling before the hea-

ter is put back into service.

The manufacturers warranty covers manufacturing defects but not malfunction caused because of the need for service.

The case surface can be cleaned with soapy water or a non-abrasive cleaning agent, using a soft cloth.

Содержание CELT STAR C

Страница 1: ...s one piece case the water heater comprises One piece chassis made of protected steel sheet Deflector Heat exchanger made of protected copper Combustion chamber Multi gas burner made of stainless stee...

Страница 2: ...bar 3 lb in2 Minimum water pressure to operate the low pressure valve 0 1 bar 1 5 lb in2 Maximum normal pressure water pressure with governor 10 bar 145 lb in2 Maximum low pressure water pressure with...

Страница 3: ...rised contractor Installation pipes should be fitted in accordance with BS 6891 Pipework from the meter must be of adequate size Pipes of a smaller size than the gas connection should be not used The...

Страница 4: ...appliance is delivered complete ready to install The accessories pouch contains the following items Natural gas connection fig 5 one valve 3 4 F 1 2 M with 1 2 gasket one brazed angle socket 14 x 0 75...

Страница 5: ...refer to the Technical characteristics In the case of a higher supply pressure the maximum gas power can be adjusted by proceeding as follows detach the stop from the fascia fig 7a place it on the ga...

Страница 6: ...the gas control knob 6 Fig 10 6 Controls and use Fig 11 Control panel fig 11 Gas control knob symbols Off Reduced power Pilot ignition Intermediate piezo triggering powers Pilot position Maximum power...

Страница 7: ...fitted with a system enabling the user to limit its maximum power To do this turn the knob until it is between the and This appliance operates in such a way that it can be used over a wide range of f...

Страница 8: ...thout being connected to a flue After shutdown the water heater is in the safety position After approximately five minutes it can be turned on again manually following the normal lighting procedure If...

Отзывы: