background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

This appliance, intended for intermittent use, is designed to sup-
ply hot water to one draw off point such as the kitchen sink or a
wash basin.

Appliance identification :

Celt Star CT with mixing taps -

A.M.I

Celt Star C without mixing taps - 

S.M.I

Contents :

Page

1. Characteristics ...................................................................2

2. Installation Requirements ..................................................3

3. Heater installation ..............................................................4

4. Commissioning...................................................................5

5. Fitting the case...................................................................6

6. Controls and use................................................................6

7. Frost precautions ...............................................................7

8. Servicing ............................................................................7

9. Guarantee ..........................................................................8

10. Overflow safety...................................................................8

11. Operating Defects ..............................................................8

Description:

The water heater is packaged in one box.
Inside its one-piece case, the water heater comprises:

- One-piece chassis made of protected steel sheet
- Deflector
- Heat exchanger made of protected copper
- Combustion chamber
- Multi-gas burner made of stainless steel
- Removable injector-holder manifold
- Pilot with fail-safe by thermocouple and atmosphere 

sensing device.

- Gas valve
- Gas ignition and flow control knob
- Water valve with built-in overheat limiter and scale 

reducer

- Fouling prevention thermal safety device
- Hot water tap ("A.M.I" models)
- Cold water tap ("A.M.I." models).
- Spout

14

13

12

11

10

9

8

7

6

5

4

3

2

1

CELT STAR C

GAS-FIRED WATER HEATER

Category: I 2E+
Installation and use instructions

These installation and User instructions are intended for appliances installed in Great Britain.

Fig. 1

Model 

S

.

M

.

I

.

Fig. 2

Model 

A

.

M

.

I

.

11

12

10

8

7

4

1

9

6

5

3

2

c

13

14

Содержание CELT STAR C

Страница 1: ...s one piece case the water heater comprises One piece chassis made of protected steel sheet Deflector Heat exchanger made of protected copper Combustion chamber Multi gas burner made of stainless stee...

Страница 2: ...bar 3 lb in2 Minimum water pressure to operate the low pressure valve 0 1 bar 1 5 lb in2 Maximum normal pressure water pressure with governor 10 bar 145 lb in2 Maximum low pressure water pressure with...

Страница 3: ...rised contractor Installation pipes should be fitted in accordance with BS 6891 Pipework from the meter must be of adequate size Pipes of a smaller size than the gas connection should be not used The...

Страница 4: ...appliance is delivered complete ready to install The accessories pouch contains the following items Natural gas connection fig 5 one valve 3 4 F 1 2 M with 1 2 gasket one brazed angle socket 14 x 0 75...

Страница 5: ...refer to the Technical characteristics In the case of a higher supply pressure the maximum gas power can be adjusted by proceeding as follows detach the stop from the fascia fig 7a place it on the ga...

Страница 6: ...the gas control knob 6 Fig 10 6 Controls and use Fig 11 Control panel fig 11 Gas control knob symbols Off Reduced power Pilot ignition Intermediate piezo triggering powers Pilot position Maximum power...

Страница 7: ...fitted with a system enabling the user to limit its maximum power To do this turn the knob until it is between the and This appliance operates in such a way that it can be used over a wide range of f...

Страница 8: ...thout being connected to a flue After shutdown the water heater is in the safety position After approximately five minutes it can be turned on again manually following the normal lighting procedure If...

Отзывы: