F.  ELECTRICAL SYSTEM

 

 

DC SYSTEM  (12 VOLT  BATTERIES)

 

 

This system powers lights, pumps, electronics, anchor windlass and engine start. There are 
two banks of batteries forward in the engine room, the portside bank is engine start batteries 
and the starboard side bank is house and inverter batteries. 

 

There are  three battery selector switches one  in  the  wheel house  and  two  forward  in  the 
engine room. 

 

The red selector switch located on the forward bulkhead in the engine room marked 

“MAIN” 

should be left in the 

“ON” position. (i.e. house bank). 

 

A red selector switch located on the forward bulk head in the engine room marked 

“inverter” 

is the inverter switch and should be left in the 

“ON” position again to save your engine start 

bank. 

 

The red main generator DC switch is also on the forward engine room bulkhead and marked 
“Generator.”  This switch should be left in the “ON” position in order to be able to start the 
generator. 

 

The engine start selector switch is located on the engine room forward bulkhead; this switch 
should be left in the 

“BOTH” position. 

 

In the event of dead start batteries:

 

 

The engine start selector switch can be placed in the both position tying the house, inverter 
and  engine  start  battery

’s  together  providing  the  additional  power  needed  to  start  the 

engines.  Once the engines have started switch back to position #2. 

 

The engine start bank located on the portside consists of two 4D batteries. The house and 
inverter bank located on the starboard side consist of 8 - 6 volt batteries. The generator batter 
is also a 4D battery located starboard side aft. The main cabin lights operate from the AC 
breaker marked 

“Cabin Outlets.” 

 

GENERATOR

 

 

• 

Prior to starting the generator turn everything off on the AC panel.

 

On the AC panel, switch shore power off and generator On 

•  To start generator: 

 

Hold down Preheat toggle. Preheat 30 seconds  

 

Depress both start and pre heat toggles to start

 

•  Once the generator starts 

Release both switches 

Turn on the desired equipment to be used on the AC panel. 

Содержание Hullabaloo

Страница 1: ...o US flagged Make Model Year C L Marine 47 Sea Ranger 1986 Home Port Anacortes Washington USCG registration 999965 US Customs CBP 4541075 Washington Park N A Chartered thru Anacortes Yacht Charters 24...

Страница 2: ...es Page 4 D Fuel Water and Holding Tank Page 6 E Electronics Page 7 F Electrical System Page 8 G Cabin Heat Page 9 H Head Page 10 I Galley Page 10 J Bilge Pumps Page 11 K Anchoring Page 11 L Dinghy Pa...

Страница 3: ...sk any questions pertaining to any aspect of the operation of equipment navigation or even the best scenery and fishing holes Thank you and enjoy your cruising of the islands A VESSEL SPECIFICATIONS C...

Страница 4: ...cted ascertain the source and correct the problem if possible Run the blower or open hatches to help clear fumes from engine compartment before starting engine C ENGINES Access to engine room is throu...

Страница 5: ...top and pull basket out for better access Clean debris in the strainer basket 5 Once the sea strainer is free of debris replace basket secure top and tighten down the wing nuts 6 Open thru hull valve...

Страница 6: ...the remainder of the tank cautiously because the penalty for discharge of oil into navigable waters is costly Always have oil soaks or rags close by while fueling too immediately and thoroughly clean...

Страница 7: ...n approximate position and description of the vessel DEPTH SOUNDER There are two depth sounders on board One is located in the wheel house and a second on the fly bridge Piloting should always be with...

Страница 8: ...rt the generator The engine start selector switch is located on the engine room forward bulkhead this switch should be left in the BOTH position In the event of dead start batteries The engine start s...

Страница 9: ...heel house on the port side Please refer to the manufacture s operating manual for instruction G CABIN HEAT Hullabaloo cabin heat is provided by a Webasto hydronic diesel heater The heater is controll...

Страница 10: ...switch should stay in the Off position unless it is being used Valve in lazarette must be opened BEFORE turning switch on Even though the vessel is equipped with macerator and overboard pumps it is IL...

Страница 11: ...e is a sump pump under the floor deck in the forward cabin The switch on the DC electrical panel should be left on K ANCHORING Hullabaloo has a main and stern or spare anchor and rode The main is appr...

Страница 12: ...hook on rode at windlass hook on chain and tie off on windlass Recovering anchor Engines should be running while operating windlass Use care not to damage windlass or anchor platform by placing excess...

Страница 13: ...fill port starboard and port on steps of walk around Fill water tanks 2 fill ports starboard and port aft area of walk around Empty the holding tank see Section D DOCKING PROCEDURES Whenever preparin...

Страница 14: ...please advise your Check In host Extra storage is located under the settees in the salon Never use countertops for cutting please always use the cutting board Please keep things tidy and return anythi...

Отзывы: