WARNINGS

Prolonged short circuit of any supply can cause damage to the unit.

Take the necessary precautions in not allowing liquids to spill on or into the unit.

STANDARDS

This unit conforms to ECD 89/336/EEC & LVD 73/23/EEC. It has been tested and proven to

meet all current emission and immunity regulations as set out by the EEC. This unit complies

with BS4737 part 1 1988 which relates to security control equipment.

WARRANTY STATEMENT

C & K Systems offers a two and a half year warranty from the date of manufacture for this

product.

If for some reason the unit fails in the first six months, C & K will replace the unit free of charge.

If it fails in the remaining two years, return the unit to C & K systems, and we will test the unit. If

it is found “customer damaged,” a charge will incur. Otherwise the unit will be repaired and

returned free of charge.

PRODUCT DESCRIPTION

The Securit 800L+ is an 8-zone programmable microprocessor control panel using state of the

art technology and manufacturing techniques. The control panel has many advanced features

that can only be found in more expensive control panels. These features include two user

codes, Chime, Fire, and Keypad PA. Many options in the programming functions allow the

control panel to be versatile and user friendly. This panel is the ideal choice for residential and

light commercial installations.

AVAILABLE PARTS

The following selection of spares and extras are available:

Remote Keypad - giving full control over the control panel.

Spare PCB - for replacement in the event of failure.

Keyswitch - giving simple set/unset operation.

You can obtain these items from your original place of purchase.

INTENDED USE

This control panel is designed to be used in residential and light commercial applications such

as homes, small shops, and so on.

Содержание SECURIT ST800L+

Страница 1: ...INSTALLATION MANUAL SECURIT 800L CONTROL PANEL ST800L...

Страница 2: ...mote Keypad 7 POWERING UP 7 Initial Power Up 7 PROGRAMMING 8 Exit Time 8 Entry Time 8 Sounder Duration 9 Night Set Home Set Exit Time 9 Circuit Programming 10 Extended Programming Options 10 Home Set...

Страница 3: ...e the unit will be repaired and returned free of charge PRODUCT DESCRIPTION The Securit 800L is an 8 zone programmable microprocessor control panel using state of the art technology and manufacturing...

Страница 4: ...eight 2 7 kg Excluding Battery Stand by Battery 7 0Ahr max valnve regulated lead acid Standby Time load dependent 24 hrs with 2 8Ahr nom 60 hrs with 7 0Ahr nom based on panel keypad 2 PIR 40 20 25 25m...

Страница 5: ...corrected by a qualified electrician to ensure continued safe operation CAUTION Under certain circumstances the transformer metalwork can reach 70 C This is normal and well within prescribed limits B...

Страница 6: ...hat the sounder trigger is applied negative Negative ring ST Strobe switched negative trigger S Sounder switched negative trigger Sounder hold off strobe positive supply Sounder hold off supply sounde...

Страница 7: ...MUST wire in series See the Glossary for series and parallel examples POWERING UP INITIAL POWER UP Note Keep the lid off the main control panel in order to enter engineer mode Alternatively you can e...

Страница 8: ...e lid of the panel or keypad PROGRAMMING Once the panel is in engineering mode the following options are available EXIT TIME 3 0 Range 10 90 seconds Enter 3 0 The factory default is 30 seconds You can...

Страница 9: ...he selection The accept tone then sounds Note If extension speakers are fitted in Night and Home set you can alter the exit sounder volume by the control on the PCB marked VOLUME Option Option Results...

Страница 10: ...ULL SET Turn and hold for 2 0 seconds PART SET EXTENDED PROGRAMMING OPTIONS 7 Range 1 8 The control panel offers the following additional options Enter 7 1 Disables sounder and strobe in Night Set Ent...

Страница 11: ...subsequent alarms as well as isolated circuits First to alarm is shown by the LED being ON continuously Subsequent alarms are shown by the LED s flashing and isolated circuits are shown by LED s puls...

Страница 12: ...code to prevent unauthorised alteration To enable this the engineer code must end in 9 If the engineer code is lost it will not be possible to enter engineer mode the PCB will need to be replaced Thi...

Страница 13: ...m the exit time drops to 8 seconds as soon as the EXIT door has closed thus avoiding the preset exit time FULL SET KEYSWITCH Allows the panel to be set unset and reset through zone 8 Note The keyswitc...

Страница 14: ...RY VOLTAGE V AUX VOLTAGE V INSTALLED BY SOUNDER CONNECTIONS CONTROL PANEL ST S R SONADE 2000 STROBE B D A T FLASHGUARD XL STROBE SIREN SUPPLY SUPPLY TAMPER OUT STARLIGHT 2000 ST R H H RTN ACTIVEGUARD...

Страница 15: ...ne activates even in day mode Programmed to PA or FIRE Reprogram the zone to be an alarm zone or similar If you are still experiencing problems then contact our technical helpline with information at...

Страница 16: ...STEMS is always endeavouring to improve quality and specification of all its products and may alter or amend this product and instructions without notice C K Systems Ltd Unit 24 Walkers Road North Moo...

Отзывы: