Use the screen to select the hardware you are using. The Ubob THC Plugin should be
selected. If you have a ESPC Power supply (part of all RouterPak and PlazPak
products) then be sure to check that as well. Note the COM port selection box. In most
circumstances that will stay on
“
1
”
.
A
A
Activate the recessed TEST Button on the front panel of the MP3000-DTHC or
your unit with the DTHC module installed and connected. The TEST LED should
start flashing.The unit goes into a test sequence where the TIP VOLTS DRO is set to
100 and the UP screen LED flashes 5 times. Then the TIP VOLTS DRO is set to
150 and the DOWN LED flashes 5 times. This test sequence repeats until you hit
the Test Button again and the TEST LED stops flashing.
If the test does not show the above results the most probable cause is the serial
communications is not working between the PC and the MP3000. Make sure you
have the right port selected. If you were sent a special serial cable with the RS232
buffer module (see photo) make sure it is installed correctly.
DYNAMIC SELF-TEST of DTHC MODULE
PAGE 5