![C&B Technology AN120 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/candb-technology/an120-series/an120-series_communications-manual_3069197016.webp)
- 16 -
A(V)N(P)120
’
s Protocol Version 1.1
Æ
Disable Motion Detection Function
Æ
Display only “MD” in the screen
Æ
Display “MD” and transmit MD Alarm Packet
Æ
MD area : Upper side of the picture
Æ
MD area : Lower/Left/Right side of the picture
Æ
MD area : Center of the picture
Æ
MD area : Whole Region of the picture
Æ
2 hex ~ F hex : MD Sensitivity
(high sensitivity ~ low sensitivity)
(!!)
Motion Detection Response(Alarm) Packet :
*NNDDDDDDYY
(ex) Set “MD” and transmission of the MD Response
packet, “MD” area is Center, MD sensitivity 7.
* NN A1 02 27 YY
00
01
02
0
1
2
3
x
P
S
*NNA1QQPSYY
Motion Detection
(Don’t)Transmit Command Response Packet
Æ
Enable Transmission of Command Response Data
Æ
Don’t Transmit the Command Response Data
00
01
PP
*NNA8PPXXYY
Set
the transmission
of Command
Response Packet
Camera will (not) check the camera ID
Æ
Disable ID check
Æ
Enable ID check
00
01
PP
*NNA4PPXXYY
ID check
Change Camera ID
Æ
00 ~ FF hex(total 256 IDs) New Camera ID
x
PP
*NN74PPXXYY
ID change
Key Action will be activated by this command.
Æ
Key Code
See Key action command
x
PP
*NN75PPXXYY
Key Action
Camera Power ON/OFF
Æ
OFF
Æ
ON
00
01
PP
*NN76PPXXYY
Power on/off
x
Read Current Camera ID
Æ
00 ~ FF hex(total 256 IDs) Camera ID
RR
*NN73XXXXYY
*RR000000YY
ID read
Toggle the camera ID.
ON
Æ
OFF
Æ
ON…..
*NN72XXXXYY
ID on/off
Reset the camera
*NN71XXXXYY
Reset camera
Contents
Command
Option
Command Packet
Command
Message
General Control Commands - 1