INSPECTION LIMITS FOR FOG LAMPS
The inspection limits for symmetrical fog lamps installed with universal mounting
applications, shall be with the top edge of the high-intensity zone at horizontal or below
and with the center of the high-intensity zone from 100 mm (4") left to 100mm (4") right on
a viewing screen located at 7.6m (25') from the vehicle.
Inspection limits (shaded area) for
the top edge and center of the high-
intensity zone of
.
FOG LAMPS
AIMING FOG LAMPS
The correct aim for fog lamps with symmetrical beams (as described in SAE J583) is with
the top edge of the high-intensity zone at or below the horizontal centerline and the center
of the high-intensity zone centered on the screen.
The figure shows (shaded area
indicates high-intensity zone) a
properly aimed symmetrical
on the aiming screen.
FOG
LAMP BEAM
4"
0"
4"
4"
4"
4"
0"
4"
4"
4"
4"
4
Page 17 - Aiming Procedures - Fog Lights