14
Replacing Brine Line Flow Control (BLFC)
1. Remove the red clip that secures the brine elbow.
2. Remove the BLFC holder from the elbow fitting.
3. Split the BLFC holder apart and remove the flow washer.
4. Reassemble using the reverse procedure.
TIP: Markings on the
BLFC washer should face
the direction as shown
here.
Replacing Drain Line Flow Control (DLFC)
1. Remove the red clip that secures the drain line elbow.
2. Remove the BLFC washer from the elbow fitting.
3. Reassemble using the reverse procedure.