background image

7  

Installing the Self-Piercing Inlet Saddle Valve  

The self-piercing saddle valve is designed for use with 3/8” to 1/2” OD soft 
copper supply tubing. 

 

1.  Turn off cold water valve from under sink or main water line valve for 

whole house. 

2.  Before installing self-piercing valve, make sure piercing lance does not 

protrude beyond rubber gasket. 

3.  Assemble saddle valve on copper tubing. 
4.  Tighten screw to fasten saddle valve to copper tubing. 

5.  Turn  handle  clockwise  to  pierce  soft  copper  tube  until  valve  is  firmly 

seated.  (Valve is closed in this position). 

6.  Turn on water supply to pressure cold water line and check for leaks. 

Installing the Unit 

When installed under a sink the unit is normally mounted to the right or left sink cabinet sidewall.  It is sug-
gested  to  locate  the  system  where  it  can  be  easily  accessed  or  even  removed off  the  hanging  screws  and 

pulled back out from the sink to change the filters. 

 

1.  Locate the unit in the desired position.  Make sure it is at least 3” off the floor.  Level it and mark the loca-

tion of mounting screws. 

2.  Install the screws.  Leave 1/4” of the screw head out from the wall. 

3.  Install the mounting bracket slots over the screws and hang the unit. 

 

Installing the Drain Saddle 

Prior to proceeding it is important to inspect the condition of drain pipes to 
make sure they are not thin and frail.  The drain saddles are designed to 

be installed on standard 1-1/4” - 1-1/2” OD drain pipe. 

 

Install drain saddle above (and before) the trap and on the vertical or hori-
zontal tailpiece. Never install it close to the outlet of a garbage disposal or 

plugging  of  the  RO  drain line  may  result  .    Refer  to location  in  Figure  1 

page 4. 
 

1.  Position half of the saddle with quick connect fitting at selected location 

and mark for the opening. 

2.  Drill 1/4” - 3/8” hole at mark through one side of pipe.  Position both 

halves of  the saddle on drain pipe so quick connect opening lines with 

hole.  Add the gasket to the same side as the drilled hole. 

3.  Secure drain saddle clamp with bolts and nuts provided.  (Do not over 

tighten and make sure there is equal space between saddle halves on 

each side). 

Figure 2. Self-Piercing Inlet  
Saddle Valve 

Figure 3. Drain Saddle 

Содержание RO 75 GPD 4 STAGE BP

Страница 1: ...COMMENDED TO WAIT UNTIL THE ENTIRE SYSTEM IS PRESSURIZED INCLUDING STORAGE TANK FAUCET AND RE CHECK FOR ANY LEAKS BEFORE LEAVING INSTALLATION SITE IT IS NORMAL FOR SOME BLACK CARBON FINES TO APPEAR IN...

Страница 2: ...ms use four stages of treatment to filter your water Stage 1 Remove sand dirt sediment Stage 2 Remove chlorine taste odors very fine particulates Stage 3 Reduce total dissolved minerals Stage 4 Polish...

Страница 3: ...em can be installed to provide the feed water for these features but you should consult your fridge owners manual for further information Guidelines for component placement are as follows Faucet shoul...

Страница 4: ...ered water ready for use Faucet Standard used to dispense RO water when needed Optional air gap and designer faucets are available Post Carbon Filter is provided for a final polish to provide great ta...

Страница 5: ...ank Failure to do so could result in a leak that is not spotted until after the installer has left the loca tion Installing the Membrane When handling membranes be sure hands are clean and sanitized o...

Страница 6: ...oves eye protectors To make the faucet mounting hole if sprayer or second hole is not used check below to make sure the drill does not interfere with anything below the sink Center punch a small inden...

Страница 7: ...f the floor Level it and mark the loca tion of mounting screws 2 Install the screws Leave 1 4 of the screw head out from the wall 3 Install the mounting bracket slots over the screws and hang the unit...

Страница 8: ...nnect 3 8 tubing storage tank 4 Connect tubing to inlet water supply valve For air gap models connect 1 4 tubing to faucet and 3 8 tubing from faucet to drain saddle 5 Check all connections to be sure...

Страница 9: ...aks 3 Allow system to process water for approximately 1 hour at which point tank will be practically full 4 Open faucet again and allow tank to empty for a second time It is normal to see some black c...

Страница 10: ...bing into fitting 2 Defective tubing 2 Cut damage section of tubing and re install Not enough product water Pump not running Pump running but system not producing water Leaks Spare Parts List RO 75 GP...

Страница 11: ...NE HOUSING PP 1 22 41203005 CONTROLLER 1 23 41323002 LARGE SINGLE CLAMP PP 2 24 41209004 SOLENOID VALVE 420ML MIN 1 25 41317002 CONTROL BOX pp 1 26 42005016 PRODUCT WATER CHECK VALVE 3 8 O D 3 8 O D 1...

Страница 12: ...ce any part which fails two 2 years from date of manufacture as indicated by the serial number or date code provided the failure is due to a defect in material or workmanship The only exception shall...