1. If your hot water tank is electric, turn off the power to it to avoid damage to the element 

in the tank. 

2. If you have a private well, turn the power off to the pump and then shut off the main wa-

ter shut off valve.  If you have municipal water, simply shut off the main valve.  Go to the 
faucet, (preferably on the lowest floor of the house) turn on the cold water until all pres-

sure is relieved and the flow of water stops. 

3. Locate the Speciality System tank and brine tank close to a drain where the system will 

be installed.  The surface should be clean and level. 

4. Connect the inlet and outlet of the Speciality System using appropriate fittings.  Perform 

all plumbing according to local plumbing codes. 



Use a ½” minimum pipe or tubing size for the drain line 



ON COPPER PLUMBING SYSTEMS BE SURE TO INSTALL A GROUNDING 
WIRE BETWEEN THE INLET AND OUTLET PIPING TO MAINTAIN GROUND-

ING. 

Any solder joints near the valve must be done before connecting any piping to the valve.  

Always leave at least 6" (152 mm) between the valve and joints when soldering pipes that 

are connected to the valve.  Failure to do this could cause damage to the valve. 
 

5. Connect the drain hose (10 ft included) to the valve and secure it with a hose clamp (also 

included).  Run the drain hose to the nearest laundry tub or drain pipe.  This can be ran 

up overhead or down along the floor.  If running the drain line more than 20 ft overhead, 
it is recommended to increase the hose size to 3/4”.  NEVER MAKE A DIRECT CONNEC-

TION INTO A WASTE DRAIN.  A PHYSICAL AIR GAP OF AT LEAST 1.5” SHOULD BE USED 

TO AVOID BACTERIA AND WASTEWATER TRAVELLING BACK THROUGH THE DRAIN 
LINE INTO THE SPECIALITY SYSTEM. 

6. Using the Allen Key (included), place the unit in the bypass position.  Slowly turn on the 

main water supply.  At the nearest cold treated water tap nearby remove the faucet 

screen, open the faucet and let water run a few minutes or until the system is free of any 

air or foreign material resulting from the plumbing work. 

7. Make sure there are no leaks in the plumbing system before proceeding.  Close the water 

tap when water runs clean. 

8. Open the brine tank / cabinet salt lid and add water based on the chart below.  Do not 

add salt to the brine tank at this time. 

9. Proceed to start up instructions. 

Note:  The unit is not ready for service until you complete the start-up instruc-

tions. 

Installation Instructions 

Содержание 785 HIMTLC PLUS Series

Страница 1: ...fied lubri cant to all seals 3 This system is not intended for trea ng water that is microbiologically unsafe or of unknown quality without adequate disinfec on before or a er the system 4 Backwash f...

Страница 2: ...water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize the...

Страница 3: ...ly lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pre...

Страница 4: ...Exchange Media ft3 1 32ft3 1 76 ft3 2 20 ft3 2 64 ft3 Tank Size 10x54 12x52 13x54 14x65 Top Cone Yes Yes Yes Yes Tank Jacket Media Loaded Yes No No No Brine Tank Inches 20 3 x 37 4 20 3 x 37 4 20 3 x...

Страница 5: ...e Damage caused by freezing is not covered by the warranty Put the Speciality System in a place water damage is least likely to occur if a leak de velops The manufacturer will not repair or pay for wa...

Страница 6: ...you may lose capacity and experience breakthrough for Iron Mn or Tannins To be safe choose one size larger when sizing Any oxidative pre treatment such as air or chemicals is unnecessary and should be...

Страница 7: ...brine tank When the water in the brine tank has been drawn into the mineral tank 10 15 minutes unplug the valve 5 Turn the bypass handles to the bypass mode 6 Allow the unit to sit over night 8 hours...

Страница 8: ...alve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub...

Страница 9: ...9 Installation...

Страница 10: ...ll amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on the by...

Страница 11: ...daily use and the reserve ca pacity of the system SALT SETTING There are 3 settings to choose in the MENU SET TINGS These settings will determine the salt dosage and capacity for the system For SIM un...

Страница 12: ...ll pause on the Date and Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be dis played To man...

Страница 13: ...time during the night and manual regenerations should be performed when little or no water will be used in the household Normal regeneration time is 2 00 AM When the system capacity is near exhausted...

Страница 14: ...ly NUGGET or PELLET water Speciality System salt Check the salt level monthly It is important to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt dir...

Страница 15: ...the control valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriv...

Страница 16: ...16 Main Repair Parts Connectors A A A B D F E A C 21363...

Страница 17: ...17...

Страница 18: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 19: ...m clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your specialty system to freezing or to temperatures above 100 F Resin Cleaner DO NOT USE an...

Страница 20: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 21: ...21...

Страница 22: ...22 Power Head Exploded View...

Страница 23: ...60010099 Screw ST2 9X13 Large Washer A24 2 60010100 Washer 3x13 B09 1 60095078 BNT85 Main Gear B10 1 60095093 BNT185 Housing B11 1 92392 BNT85HE Brine Gear Downflow B12 1 60010672 Magnet 3 2 7 B13 1...

Страница 24: ...24 Trouble Shooting...

Страница 25: ...anature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times oper...

Отзывы: