background image

Page 14 of 16 

 

10

 

Warranty 

Lifetime Limited Warranty

 

Each ADH Inc. CANARY will be free from defects in material and workmanship 
for its lifetime. As used herein, “lifetime” is defined as seven years after ADH Inc. 
discontinues manufacturing the product, but the warranty period shall be at least 
ten  years  from  the  date  of  purchase.  This  warranty  does  not  cover  fuses, 
disposable  batteries,  damage  from  neglect,  misuse,  contamination,  alteration, 
accidental  or  abnormal  conditions  of  operation  or  handling,  including  failures 
caused by use outside of the product’s specifications, or normal wear and tear of 
mechanical components. This warranty covers the original purchaser only and is 
not transferable. 

 

For  ten  years  from  the  date  of  purchase,  this  warranty  also  covers  the  LCD. 
Thereafter, for the lifetime of the CANARY, ADH Inc. will replace the LCD for a 
fee based on then current component acquisition costs. 

 

To  establish  original  ownership  and  prove  date  of  purchase,  please  complete 
and return the warranty card at the end of this manual or register your product 
on 

http://www.ewact.com

. ADH will, at its option, repair at no charge, replace or 

refund  the  purchase  price  of  a  defective  product  purchased  through  an  ADH 
authorized sales outlet and at the applicable international price.  ADH reserves 
the right to charge for importation costs of repair/replacement parts if the product 
purchased in one country is sent for repair elsewhere. 

 

If the product is defective, contact your nearest ADH authorized service center 
to obtain return authorization information, then send the product to that service 
center, with a description of the difficulty, postage and insurance prepaid (FOB 
Destination). ADH assumes no risk for damage in transit. ADH Inc. will pay return 
transportation for product repaired or replaced in-warranty. Before making any 
non-warranty repair, ADH Inc. will estimate cost and obtain authorization, then 
invoice you for repair and return transportation. 

 

THIS  WARRANTY  IS  YOUR  ONLY  REMEDY.  NO  OTHER  WARRANTIES, 
SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR 
IMPLIED. ADH Inc. SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES  OR  LOSSES,  INCLUDING 
LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED 
RESELLERS  ARE  NOT  AUTHORIZED  TO  EXTEND  ANY  DIFFERENT 
WARRANTY  ON 

ADH  Inc’s  BEHALF.  Since  some  states  do  not  allow  the 

exclusion  or  limitation  of  an  implied  warranty  or  of  incidental  or  consequential 
damages, this limitation of liability may not apply to you. If any provision of this 
warranty is held invalid or unenforceable by a court or other decision-maker of 
competent jurisdiction, such holding will not affect the validity or enforceability of 
any other provision. 

 

Содержание EWACT 101

Страница 1: ...USER MANUAL EWACT 101 Electrified Water and Current Tester...

Страница 2: ...Make a Grounded Connection 8 6 3 Operation Modes 9 6 3 1 Unit Test Mode 9 6 3 2 Voltage to Ground Mode 9 6 3 3 Direction Mode 10 6 4 Disassemble the CANARY 10 7 Care and Maintenance 11 7 1 General Ca...

Страница 3: ...direction from which the current is introduced 2 1 Intended Use While the unit has been designed to detect AC electricity in a conductive fluid the main purpose for its development is to detect stray...

Страница 4: ...4 of 16 3 Parts of the CANARY Note Wiring Harness and 15 Ground Adapter Cord not shown Short Handle Long Handle Head Module Gooseneck Collapsed Position Expanded Position Probe Arms Clamp Base Unit Pr...

Страница 5: ...Page 5 of 16 Head Module Contents Owner s Manual not shown...

Страница 6: ...rer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and tags and decals affixed to this unit are therefore not all inclusive If you use a...

Страница 7: ...at the unit is operating correctly 2 Presence of Stray Electricity In the Voltage to Ground mode the CANARY will alert the operator with a visual and audible alarm when electrical current of 1 volt or...

Страница 8: ...s to secure the probe arms in the extended position 8 The unit is now ready to use 6 2 Make a Grounded Connection This step is required when using the Voltage to Ground mode This allows the meter to r...

Страница 9: ...r Support 6 3 2 Voltage to Ground Mode Configuration Power switch to On Selector switch positioned to Voltage to Ground Green Yellow ground adapter cord connected to AC outlet to facilitate ground Pro...

Страница 10: ...gets closer to the source the voltage will increase on the meter 6 4 Disassemble the CANARY NOTE Always perform a Self Test at the end of use to verify the unit is still in working order This will ens...

Страница 11: ...eter on flat surface 3 Use a 1 16 Allen key to loosen and remove selector switch 4 Use a Philips screwdriver to loosen and remove 4 cover screws 5 Lift cover off and replace 9v battery located inside...

Страница 12: ...120 hours minimum Operating Temperature 0 C to 55 C 32 F to 131 F Storage Temperature 21 C to 60 C 5 F to 140 F Relative Humidity 0 to 90 0 C to 37 C 0 to 65 37 C to 45 C 0 to 45 45 C to 55 C Operati...

Страница 13: ...Page 13 of 16 9 Technical Support For technical support please contact ADH Inc Toronto On 416 624 8921 help adh inc com BFAM Industries Willis TX 936 520 0994 customersupport bfamindustries com...

Страница 14: ...nternational price ADH reserves the right to charge for importation costs of repair replacement parts if the product purchased in one country is sent for repair elsewhere If the product is defective c...

Страница 15: ...al Number Date of Purchase Where Purchased Print Name Address Email My signature below acknowledges that I have read fully understand and accept this limited warranty agreement Signature Date Must ret...

Страница 16: ...Page 16 of 16...

Отзывы: