background image

Pin

A

A

B

B

B

B

Lever
arm

TOP

BOTTOM

TOP

Lever
arm

BOTTOM

TOP

BOTTOM

TOP

Lever
arm

Pin

BOTTOM

9500M

SERIES

MORTISE LOCK EXIT DEVICE (FIRE) - INSTALLATION INSTRUCTIONS

1.  Device is factory pre-set as LHR

2.  Knock out the pin in the direction (as shown), take 
       out the lever arm assembly

3.  Rotate the chassis 180° and install the lever 
      arm and insert pin as shown

4.  Device is converted to RHR

TO CHANGE HAND OF EXIT DEVICE CHASSIS:

TO CHANGE LOCK BODY HAND 

OF FIELD REVERSIBLE MORTISE LOCK:

NOTES:
a) Prepare door and door frame as per supplied templates and 
    instructions on Sheet 2.
b) If no trim is used, install lock body and exit device only. Level railing 
    assembly and attach railing end mounting bracket to door using 
    through bolts (not supplied) and machine screws.
c) If trim is used, refer to sheet 2 and to trim installation instructions
   to prepare door for the appropriate trim.

9500M-INS-EN-2015-02   

1/2

If it is necessary to change handing, follow the instructions below:

1.  Use hex key to unfasten the screw in the hole behind latch bolt (green label).
2.  Pull latch bolt out from the front of the lock case.
3.  Rotate latch bolt 180° to proper handing and push latch bolt back into lock case.
4.  Securely tighten the screw in the hole and secure with Thread locker (Loctite 242).
5.  Handing is now reversed.

LEFT HAND REVERSED (LHR) SHOWN

Right hand (or LHR) lock shown
for LHR exit device installation

Before installing the exit device, verify the following:
1.  Door is properly fitted and hung.
2.  Door surface on which the exit device will be installed is flush and flat.
3.  Verify if the exit device length is suitable for the applicable door width. If the exit device mounting rail requires to be shortened see below:

   a.  The 3’ exit device model can be cut to fit doors from 30” (762mm) to 36” (914mm) in width (refer to section 4 on sheet 2.)

          b.  The 4’ exit device model can be cut to fit doors from 36” (914mm) to 48” (1219mm) in width (refer to section 4 on sheet 2.)
4.  Exit device handing (refer to illustration below.)
5.    Lock function and trim compatibility.
6     Review all templates and installation instructions prior to any door preparation.
NOTE: Mortise exit device is meant to be used with a compatible exterior trim. Refer to section 2 on page 2.

GENERAL NOTES

Through square hole

Hole (green label)

Latch bolt

Hex key

Push Pad

Sliding Cover

Main Chassis Cover

Mortise lock
(LHR shown)

Strike

Mortise lock
body screws

Inside Door 

Surface

Screws 
A-Machine screws
    #10-24 UNC x 3/4”
B- Machine screws 
    #10-24 UNC x 3/4”
    or wood screws
    #10 x 1-1/4”

Strike 
screws

Mounting Rail

Exit device location on door
must be flush and flat

Rail Mounting
Bracket

End Cap

Main Chassis