background image

XB, HV, HVA, HVAR, ADD, ADDR, DDS, DDP, SXB, SADD  

M0112_NOV 2020

Page 8 of 8

www.CANARM.COM

Canarm Ltd. - Corporate Head Office    

2157 Parkedale Avenue, PO Box 367    Brockville, Ontario   Canada   K6V 5V6 

Tel: (613) 342-5424              Fax: (613) 342-8437               

[email protected]                      

www

.canarm.com 

Wall supply fan with steel control damper, cabinet and back guard

ADDR  & HVAR FANS

Please note for the reversing models ADDR, HVAR, the supplied reversing switch should be wired in accordance 
with the instructions supplied by the manufactures of the switch. 
 
The blade should come to a complete stop before switching direction. Failure to do so may cause damage to the 
motor and/or blade. 
 
For trouble shooting and electrical guidelines, the above instructions apply.

WARRANTY

 

 
CANARM Ltd. warrants every new fan to be free of defects in materials and workmanship, to the extent that, within a period of one 
year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, and unit or part thereof, returned 
freight prepaid, and found to be defective. 
This warranty does not include any labour or transportation cost incidental to the removal and reinstallation of the unit at the user’s 
premises. 
Components repaired or replaced are warranted through the remainder of the original warranty period only. 
This warranty applies to the original purchaser-user only; it is null and void in case of altercation, accident, abuse, neglect and 
operation not in accordance with instructions. 
 

NOTICE:

 No warranty claims will be honored by CANARM Ltd. unless prior authorization is obtained.

Installation or Product problems? Do not return to store of purchase. 

Contact Canarm Service at 1-800-265-1833 (CANADA)  1-800-267-4427 (U.S.A) 

1-800-567-2513 (EN

FRANÇAIS) Monday to Friday 8:00am - 5:00pm EST

Содержание XB

Страница 1: ...ted to a wall require a different wall opening than fans mounted in cabinets or sleeves For specific dimensions refer to the submittal drawing for the specific fan configuration 2 Mount the fan in the...

Страница 2: ...vent it from entering the shaft and propeller area 5 Disconnect switches are recommended and should be located near the fan in order to swiftly cut off power in case of an emergency and maintain compl...

Страница 3: ...the same time check the sheaves for chips dents or rough surfaces that could damage the belt The correct belt tension is important Too tight a belt will result in excess bearing pressure which can ca...

Страница 4: ...pulley Loosen the setscrews on the pulleys and remove from either the motor or fan shaft using a two or three jaw puller Remove any shaft imperfection such as setscrew mark using a file or emery cloth...

Страница 5: ...the setscrews on the bearings and then tighten one setscrew on each bearing Loosely install the bearings on the bearing mount Rotate the shaft to find the center of free movement Install the propeller...

Страница 6: ...es Improper fan installation Static pressure higher than design MOTOR OVERLOADING Impeller rotating in the wrong direction Improper fan speed Defective motor Fan speed higher than design Filters missi...

Страница 7: ...xcess of 50 pounds should also be supported using hanging rods or by supports placed underneath the fan Wall supply fan with cabinet back guard motorized shutter and weather hood The drawing below ill...

Страница 8: ...defects in materials and workmanship to the extent that within a period of one year from the date of purchase CANARM Ltd shall either repair or replace at CANARM s option and unit or part thereof retu...

Страница 9: ...re diff rente de ceux install s dans un armoire ou manchon Pour les dimensions sp cifiques reportez vous au dessin de soumission pour la configuration sp cifique du ventilateur 2 Montez le ventilateur...

Страница 10: ...r dans la zone de l arbre et de l h lic 5 Des sectionneurs sont recommand s et doivent tre localis s pr s du ventilateur afin de couper rapidement l alimentation en cas d urgence et maintenir un contr...

Страница 11: ...a courroie est importante Une courroie trop serr e peut causer une pression excessive sur les roulements ce qui peut causer une d faillance pr matur e des roulements et entra ner une surcharge du mote...

Страница 12: ...utilisant un extracteur d engrenage deux ou trois m choires Retirez tout imperfection l arbre tel que marque de vis en utilisant une lime ou d une toile meri Installez les poulies de rechange en serra...

Страница 13: ...e sur les roulements puis serrez une vis de r glage sur chaque roulement Installez les roulements sans serrer sur le support de roulement Faites tourner l arbre pour trouver le centre du mouvement lib...

Страница 14: ...concue SURCHARGE DU MOTEUR Rotation de la turbine dans la mauvaise direction Vitesse incorrecte du ventilateur Moteur d fectueux Vitesse du ventilateur plus lev e qu il est con u Filtres manquants TRO...

Страница 15: ...ection arri re volet motoris et hotte tanche Le dessin ci dessous illustre l installation typique d un ventilateur d alimentation avec un cabinet une protection arri re un volet motoris avec interrupt...

Страница 16: ...essus s appliquent GARANTIE CANARM Ltd garantit que chaque nouveau ventilateur est exempt de d fauts de mat riaux et de fabrication dans la mesure o dans un d lai d un an compter de la date d achat CA...