WALL EXHAUST FANS  

BELT & DIRECT DRIVE

INSTALLATION AND MAINTENANCE INSTRUCTIONS 

READ AND SAVE THESE INSTRUCTIONS 

Models:

 

XB, HV, HVA, HVAR, ADD, ADDR, DDS, DDP, SXB, SADD

THE PURPOSE OF THIS MANUAL IS TO AID IN THE PROPER INSTALLATION AND OPERATION OF THE 
FANS.  THESE INSTRUCTIONS ARE INTENDED TO SUPPLEMENT GOOD GENERAL PRACTICES AND ARE 
NOT INTENDED TO COVER DETAILED INSTRUCTION PROCEDURES. IT IS THE RESPONSIBILITY OF THE 
PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS 
HANDLED BY QUALIFIED PERSONNEL. 

 

 
Inspect all shipments carefully for damage. 

THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER’S 

BILL OF LADING AND FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.

 

ELECTRICAL CONNECTIONS

WARNING: BE SURE POWER IS OFF AT THE ELECTRICAL PANEL BEFORE WIRING.

WARNING: ALL ELECTRICAL WORK SHOULD BE PERFORMED 
BY A QUALIFIED ELECTRICIAN.

INSTALLATION

 

 

1.    

Cut and frame the appropriate wall opening. Fans mounted to a wall require a different wall opening than fans 

      mounted in cabinets or sleeves. For specific dimensions, refer to the submittal drawing for the specific fan 
      configuration. 

 

2.    

Mount the fan in the opening with the fan panel directly over the load bearing support and if this is not practical 

      angle supports must be provided to transfer the fan weight to the load bearing structure. 

 

3.    

Caution: The fan contains rotating parts and requires electrical service. Appropriate safety precautions should 

      be taken during installation, operation and maintenance. 

 

4.    

Warning: Do not install or operate this fan in an environment where combustible materials, gasses or fumes 

      are present unless it was specifically designed and manufactured for that application. 

 

5.    

A damper, if used, should be securely mounted in a manner that allows free and unobstructed operation. 

 

6.    

All electrical work must be done, in accordance with all applicable electrical codes, by a qualified electrician.  

      Please follow all applicable national, state/provincial and local codes, all of them will supersede this manual. 

 

7.    

Prior to wiring ensure the power supply is locked in the 

OFF

 position and that the motor nameplate voltage 

      and the supply voltage match. 

 

8.

   Be sure to keep all wiring clear of any rotating parts.  

 

9.

   Before starting the fan ensure that the wheel rotates freely.

Содержание XB

Страница 1: ...ted to a wall require a different wall opening than fans mounted in cabinets or sleeves For specific dimensions refer to the submittal drawing for the specific fan configuration 2 Mount the fan in the...

Страница 2: ...vent it from entering the shaft and propeller area 5 Disconnect switches are recommended and should be located near the fan in order to swiftly cut off power in case of an emergency and maintain compl...

Страница 3: ...the same time check the sheaves for chips dents or rough surfaces that could damage the belt The correct belt tension is important Too tight a belt will result in excess bearing pressure which can ca...

Страница 4: ...pulley Loosen the setscrews on the pulleys and remove from either the motor or fan shaft using a two or three jaw puller Remove any shaft imperfection such as setscrew mark using a file or emery cloth...

Страница 5: ...the setscrews on the bearings and then tighten one setscrew on each bearing Loosely install the bearings on the bearing mount Rotate the shaft to find the center of free movement Install the propeller...

Страница 6: ...es Improper fan installation Static pressure higher than design MOTOR OVERLOADING Impeller rotating in the wrong direction Improper fan speed Defective motor Fan speed higher than design Filters missi...

Страница 7: ...xcess of 50 pounds should also be supported using hanging rods or by supports placed underneath the fan Wall supply fan with cabinet back guard motorized shutter and weather hood The drawing below ill...

Страница 8: ...defects in materials and workmanship to the extent that within a period of one year from the date of purchase CANARM Ltd shall either repair or replace at CANARM s option and unit or part thereof retu...

Страница 9: ...re diff rente de ceux install s dans un armoire ou manchon Pour les dimensions sp cifiques reportez vous au dessin de soumission pour la configuration sp cifique du ventilateur 2 Montez le ventilateur...

Страница 10: ...r dans la zone de l arbre et de l h lic 5 Des sectionneurs sont recommand s et doivent tre localis s pr s du ventilateur afin de couper rapidement l alimentation en cas d urgence et maintenir un contr...

Страница 11: ...a courroie est importante Une courroie trop serr e peut causer une pression excessive sur les roulements ce qui peut causer une d faillance pr matur e des roulements et entra ner une surcharge du mote...

Страница 12: ...utilisant un extracteur d engrenage deux ou trois m choires Retirez tout imperfection l arbre tel que marque de vis en utilisant une lime ou d une toile meri Installez les poulies de rechange en serra...

Страница 13: ...e sur les roulements puis serrez une vis de r glage sur chaque roulement Installez les roulements sans serrer sur le support de roulement Faites tourner l arbre pour trouver le centre du mouvement lib...

Страница 14: ...concue SURCHARGE DU MOTEUR Rotation de la turbine dans la mauvaise direction Vitesse incorrecte du ventilateur Moteur d fectueux Vitesse du ventilateur plus lev e qu il est con u Filtres manquants TRO...

Страница 15: ...ection arri re volet motoris et hotte tanche Le dessin ci dessous illustre l installation typique d un ventilateur d alimentation avec un cabinet une protection arri re un volet motoris avec interrupt...

Страница 16: ...essus s appliquent GARANTIE CANARM Ltd garantit que chaque nouveau ventilateur est exempt de d fauts de mat riaux et de fabrication dans la mesure o dans un d lai d un an compter de la date d achat CA...

Отзывы: