Read Instructions Completely Before Installation & Save For Reference

Congratulations on the purchase of your quality built direct drive, wall exhaust ventilation fan. Used for general exhaust

ventilation, these fans come fully assembled and 100% of fans are tested for proper operation before shipping.

SD Exhaust Fans:

These models have a rugged, welded steel box housing with a powder coated finish and aluminum exhaust louvers. The

louvers open automatically when the fan starts up and close when the fan stops.

Instruction Manual for SD08-EC/SD10-EC

Light Commercial Wall Exhaust Fans 

INSTALLATION

Installation is fast and simple. A sturdy framed wall opening should be prepared in advance to the size indicated for your fan in

the charts above. With lag bolts for wooden frames or nut, bolt and lock washers for steel frames, secure the fan using the

four mounting holes provided, one in each corner of the fan.

WARNING: FAN IS GUARDED ON INTERIOR. EXTERIOR SHOULD BE MOUNTED AT LEAST 2.5 

                   METERS ABOVE GRADE LEVEL OR PROPERLY GUARDED FROM ACCIDENTAL 

                   CONTACT OF THE BLADE THROUGH THE LOUVERS.

WARNING: BE SURE POWER IS OFF AT THE ELECTRICAL PANEL BEFORE WIRING.

                   ALL ELECTRICAL WORK SHOULD BE PERFORMED BY A QUALIFIED 

                   ELECTRICIAN.

SD08-EC_SD10-EC-M  12/16/19                                                

Page  2 of 3

Please follow all applicable national, state/provincial and local codes. Failure to follow the safety instructions may result in

serious injury or death due to electrical shock or injury due to rotating parts.

These fans are shipped from the factory wired for full speed. The fan may be operated full speed only, low speed only (re-wire

according to wiring diagram located on the fan) or using a two-speed toggle switch. Consult factory for details.

MODEL

A x A

SQUARE

B

C

D (c/c)

SQR

(# OF 

LOUVRES)

FRAMING

SD08-EC

13 x 13

8 7/8"

5 3/16"

11"

9 3/4"

2

10" x 10"

SD10-EC

15 x 15

8 7/8"

5 3/16"

13"

11 3/4"

3

12" x 12"

   

 

 

 

   

   

 

 

 

   

ELECTRICAL CONNECTION

WARNING

!

High voltage,
disconnect 
power before 
servicing.

High Speed

Low Speed

Содержание SD08-EC

Страница 1: ...ired or replaced are warranted through the remainder of the original warranty period only This warranty applies to the original purchaser user only it is null and void in case of alteration accident abuse neglect and operation not in accordance with instructions NOTICE No warranty claims will be honored by CANARM Ltd unless prior authorization is obtained SD08 EC SD10 EC Light Commercial Wall Exha...

Страница 2: ...ut bolt and lock washers for steel frames secure the fan using the four mounting holes provided one in each corner of the fan WARNING FAN IS GUARDED ON INTERIOR EXTERIOR SHOULD BE MOUNTED AT LEAST 2 5 METERS ABOVE GRADE LEVEL OR PROPERLY GUARDED FROM ACCIDENTAL CONTACT OF THE BLADE THROUGH THE LOUVERS WARNING BE SURE POWER IS OFF AT THE ELECTRICAL PANEL BEFORE WIRING ALL ELECTRICAL WORK SHOULD BE ...

Страница 3: ...ightly when fan is not in operation The fan should always be started on high speed to open the shutters Once shuttes are open it can then be operated on low speed DO NOT PRESSURE WASH THE FAN Read Instructions Completely Before Installation Save For Reference Instruction Manual for SD08 EC SD10 EC Light Commercial Wall Exhaust Fans SD08 EC_SD10 EC M 12 16 19 Page 3 of 3 CANARM LTD 2157 PARKEDALE A...

Страница 4: ... de port payé et que nous jugeons défectueuse Cette garantie ne couvre pas les coûts de main d œuvre ou de transport occasionnés par le démontage et la réinstallation de l unité sur le site de l usager Les pièces qui seront changées ou remplacées seront garanties pour la durée de la garantie originale seulement Cette garantie s applique à l acheteur original seulement La garantie sera annulée dans...

Страница 5: ...à L INTéRIEUR VOUS DEVEZ DONC L INSTALLER à AU MOINS 2 5 MèTRES DU SOL AFIN D éVITER TOUT CONTACT ACCIDENTEL AVEC LA PALE MODÈLE A x A CARRÉ B C D c c E AU CARRÉE N QTÉ DE LOUVRES ENCADREMENT SD08 EC 13 x 13 8 7 8 5 3 16 11 9 3 4 2 10 x 10 SD10 EC 15 x 15 8 7 8 5 3 16 13 11 3 4 3 12 x 12 Noir du moteur Brun du moteur Bleu du moteur Raccordement Mise à terre de la bâtisse Mise à terre Neutre Ligne ...

Страница 6: ...VEZ PAS LE VENTILATEUR à PRESSION SD08 EC_SD10 EC M FR 12 17 19 Page 3 de 3 CANARM LTÉE 2157 PARKEDALE AVE P O BOX 367 BROCKVILLE ONTARIO K6V5V6 TÉLEPHONE 613 342 5424 FAX 1 800 263 4598 CANARM LTEE 2555 RUE BERNARD LEFEBVRE LAVAL QUEBEC H7C 0A5 TÉLEPHONE 450 665 2535 FAX 540 665 0910 USINE À ARTHUR 7686 CONCESSION 16 RR4 ARTHUR ONTARIO N0G 1A0 TÉLEPHONE 519 848 3910 FAX 519 848 3948 ENTRETIEN Mod...

Отзывы: