background image

XB, HV, HVA, HVAR, ADD, ADDR, DDS, DDP, SXB, SADD  

M0112_NOV 2020

Page 3 of 8

www.CANARM.COM

Canarm Ltd. - Corporate Head Office    

2157 Parkedale Avenue, PO Box 367    Brockville, Ontario   Canada   K6V 5V6 

Tel: (613) 342-5424              Fax: (613) 342-8437               

[email protected]                      

www

.canarm.com 

OPERATION CONTINUED 

 

Typical Installation

 - Refer to page 7

Start Up

 

       Turn the fan on and inspect for the following. 

          •    Direction of rotation  
          •    Improper motor amperage 
          •    Excessive Vibration 
          •    Unusual Noise 
          •    Improper belt tension or alignment 

 
If a problem is discovered shut off the fan and refer to 
the section on troubleshooting to discover the cause of 
the problem. The fan should be inspected after 30 
minutes, 8 hours and 24 hours of operation to ensure all 
fasteners are tight and belts are properly tensioned and 
aligned. 

MAINTENANCE WARNING

Disconnect and secure to the OFF position all electrical power to the fan prior to inspection or 
servicing. Failure to comply with this safety precaution could result in serious injury or death. 

•   Ventilators should be checked at least once a year. For critical or severe applications a routine check every two 
     to three months is suggested. 
 
•   When removing or installing a belt don’t force the belt over the sheave. Loosen the motor mount so that the belt 
     can be easily slipped over the sheave. 
 
•   The belt, on belt driven units, should be removed and carefully checked for cracks, ply separation or irregular 
     wear. A small irregularity in the contact surface of the belt will result in noisy operation. If any of these defects 
     are apparent the belt should be replaced. At the same time check the sheaves for chips, dents or rough surfaces 
     that could damage the belt. 
 
•   The correct belt tension is important. Too tight a belt will result in excess bearing pressure, which can cause 
     premature bearing failure and may cause the motor to overload, too loose a belt will result in slippage, which 
     will burn out belts. Proper belt deflection should be 1/64” (half way between sheave centers) for each inch of 
     belt span when a force of approximately 5 lbs. is applied. 
 
•   The belt alignment should be checked to be sure that the belt is running perpendicular to the rotating shafts. 
     Motor and drive shafts must be parallel. 
 
•   A periodic inspection of all fasteners should be carried out to ensure they have not loosened due to vibration. 
     Particular attention should be paid to fasteners attaching the wheel to the shaft and those attaching the shaft to 
     the bearing. 
 
•   The standard pillow blocks on belt driven fans are factory lubricated. These bearings should be lubricated on a 
     semi annual basis (more frequently in severe applications) using a high quality lithium based grease. With the 
     unit running add grease very slowly, using a manual grease gun, until a slight bead of grease forms at the seal. 
     Be careful not to unseat the seal by over lubricating or by using excessive pressure. When the bearings are  
     obstructed from view use no more than three injections with a hand operated grease gun. 
 
•   Dust and dirt on the exterior surface of the motor, fan panel and the entire fan wheel should be removed, at 
     intervals determined by the severity of the application, to ensure proper service life and safety. 
 
•   For additional safety information refer to AMCA publication 410-96,Safety Practices for Users and Installers of 
     Industrial and Commercial Fans

Содержание ADD

Страница 1: ...nted to a wall require a different wall opening than fans mounted in cabinets or sleeves For specific dimensions refer to the submittal drawing for the specific fan configuration 2 Mount the fan in the opening with the fan panel directly over the load bearing support and if this is not practical angle supports must be provided to transfer the fan weight to the load bearing structure 3 Caution The ...

Страница 2: ...event it from entering the shaft and propeller area 5 Disconnect switches are recommended and should be located near the fan in order to swiftly cut off power in case of an emergency and maintain complete control of the power source 6 Some motors may have to be removed in order to make the connections in the motor terminal box 7 Follow the wiring diagrams on the motor nameplate 1 Wall Fans Extend ...

Страница 3: ...t the same time check the sheaves for chips dents or rough surfaces that could damage the belt The correct belt tension is important Too tight a belt will result in excess bearing pressure which can cause premature bearing failure and may cause the motor to overload too loose a belt will result in slippage which will burn out belts Proper belt deflection should be 1 64 half way between sheave cent...

Страница 4: ... pulley Loosen the setscrews on the pulleys and remove from either the motor or fan shaft using a two or three jaw puller Remove any shaft imperfection such as setscrew mark using a file or emery cloth Install the replacement pulleys tightening all setscrews to the recommended torque rating see chart and ensuring that they are properly aligned Pulley alignment is achieved by moving the pulleys on ...

Страница 5: ... the setscrews on the bearings and then tighten one setscrew on each bearing Loosely install the bearings on the bearing mount Rotate the shaft to find the center of free movement Install the propeller adjusting the bearing location to center the blade in the venturi Tighten the bearing bolts to the proper torque rating Turn the propeller by hand the propeller should rotate freely with the same re...

Страница 6: ...ves Improper fan installation Static pressure higher than design MOTOR OVERLOADING Impeller rotating in the wrong direction Improper fan speed Defective motor Fan speed higher than design Filters missing TOO MUCH AIR Static pressure lower than design Fan speed higher than design Lack of electricity to the fan Fan wired improperly Broken or missing belt FAN DOES NOT OPERATE Missing or blown fuses O...

Страница 7: ...excess of 50 pounds should also be supported using hanging rods or by supports placed underneath the fan Wall supply fan with cabinet back guard motorized shutter and weather hood The drawing below illustrates the typical installation of a supply fan with a cabinet back guard motorized shutter with end switch and weather hood in a masonry wall The installer shall provide angle iron framing and sui...

Страница 8: ... defects in materials and workmanship to the extent that within a period of one year from the date of purchase CANARM Ltd shall either repair or replace at CANARM s option and unit or part thereof returned freight prepaid and found to be defective This warranty does not include any labour or transportation cost incidental to the removal and reinstallation of the unit at the user s premises Compone...

Страница 9: ...e différente de ceux installés dans un armoire ou manchon Pour les dimensions spécifiques reportez vous au dessin de soumission pour la configuration spécifique du ventilateur 2 Montez le ventilateur dans l ouverture avec le panneau du ventilateur directement sur le support porteur et si cela n est pas pratique des supports d angle doivent être fournis pour transférer le poids du ventilateur sur l...

Страница 10: ...r dans la zone de l arbre et de l hélic 5 Des sectionneurs sont recommandés et doivent être localisés près du ventilateur afin de couper rapidement l alimentation en cas d urgence et maintenir un contrôle complet sur la source d alimentation 6 Certains moteurs peuvent être retirés pour effectuer les connections électriques dans la boîte du moteur 7 Suivez le diagram de connection sur la plaque sig...

Страница 11: ... est importante Une courroie trop serrée peut causer une pression excessive sur les roulements ce qui peut causer une défaillance prématurée des roulements et entraîner une surcharge du moteur Une courroie trop détendue entraînera un glissement qui brûlera les courroies La déflexion appropriée de la courroie doit être de 1 64 po à mi chemin entre les centres des poulies pour chaque pouce de portée...

Страница 12: ...t un extracteur d engrenage à deux ou trois mâchoires Retirez tout imperfection à l arbre tel que marque de vis en utilisant une lime ou d une toile émeri Installez les poulies de rechange en serrant toutes les vis de réglage au couple nominal recommandé voir tableau et s assurer qu elles sont correctement alignées L alignement des poulies se fait en retirant les poulies de leur arbre respectif ou...

Страница 13: ...age sur les roulements puis serrez une vis de réglage sur chaque roulement Installez les roulements sans serrer sur le support de roulement Faites tourner l arbre pour trouver le centre du mouvement libre Installer l hélice en ajustant l emplacement du roulement pour centrer la pale dans le venturi Serrez les boulons de roulement au couple nominal approprié Tourner l hélice à la main l hélice doit...

Страница 14: ...ncue SURCHARGE DU MOTEUR Rotation de la turbine dans la mauvaise direction Vitesse incorrecte du ventilateur Moteur défectueux Vitesse du ventilateur plus élevée qu il est conçu Filtres manquants TROP DE VENTILATION Pression statique plus basse que celle concue Vitesse du ventilateur plus élevée qu il est conçu Perte de courant électrique au ventilateur Branchement électrique incorrect Courroie ma...

Страница 15: ...ction arrière volet motorisé et hotte étanche Le dessin ci dessous illustre l installation typique d un ventilateur d alimentation avec un cabinet une protection arrière un volet motorisé avec interrupteur d extrémité et une hotte contre les intempéries dans un mur de maçonnerie L installateur doit fournir un cadrage avec cornière et des fixations appropriées boulons hexagonaux ou vis tire fond po...

Страница 16: ... s appliquent GARANTIE CANARM Ltd garantit que chaque nouveau ventilateur est exempt de défauts de matériaux et de fabrication dans la mesure où dans un délai d un an à compter de la date d achat CANARM Ltd réparera ou remplacera au choix de CANARM toute unité ou partie de celle ci fret retourné prépayé et jugé défectueux Cette garantie ne comprend pas les frais de main d œuvre ou de transport lié...

Отзывы: