background image

A2X SERIES  

SPUN ALUMINUM EXHAUSTER

OPERATION INSTRUCTIONS AND PARTS MANUAL 

READ AND SAVE THESE INSTRUCTIONS

GENERAL SAFETY

1.

Now UL762 approved with guard.

 

2.

All electrical work must be done in accordance with all applicable electrical codes by  a  
qualified electrician. 

3.

Prior to wiring ensure the power supply is locked in the OFF position and that the motor  
nameplate voltage matches the supply voltage. 

4.

Do not install or operate this fan in an environment where combustible materials, gases or  
fumes are present. 

5. Caution:

 the fan contains rotating parts and electrical service. Appropriate safety  

precautions should be taken during installation, operation and maintenance.  
When servicing the fan motor may be hot, allow time for cooling down. 

6.

Before starting the unit, ensure the wheel rotates freely. 

7.

Check and tighten where necessary all nuts, bolts & set screws prior to fan start up (as 
some may have loosened during shipment). 

8. Please follow all applicable national, state/provincial and local codes, all of them will  

supersede this manual. 

9. Failure to follow the safety instructions in this manual may cause serious injury or  

death due to electrical shock or high speed rotating parts.

 

The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good 
general practices and are not intended to cover detailed instruction procedures. 

 

IT IS THE RESPONSIBILITY OF THE PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS 

HANDLED BY QUALIFIED PERSONNEL.

 

 
Inspect all shipments carefully for damage. 

THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER’S BILL OF LADING AND FILE A 

CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY. 

 

DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR. PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS.

 

DIMENSION & COMPONENT

M-A2X_05_13_22

Page 1 of 5

DOWNBLAST 

UPBLAST

MODEL

WHEEL

 DIA.

DRIVE

A

B

C

D

E

A2X105

10.5"

DIRECT

19"

13.0"

21.633

13.125"

19.852"

A2X120

12.25"

DIRECT

19"

13.0"

23.063

15.313"

23.160"

A2X135

13.5"

DIRECT

21"

17.25"

24.027

16.875"

25.523"

A2X150

15"

DIRECT

21"

17.25"

25.093

18.750"

28.359"

A

B

C

SECTION A-A

A

A

D

E

D

E

C

A

UPBLAST DOWNBLAST

Содержание A2X Series

Страница 1: ...provincial and local codes all of them will supersede this manual 9 Failure to follow the safety instructions in this manual may cause serious injury or death due to electrical shock or high speed ro...

Страница 2: ...RPM range would be from full RPM to the RPM just set The lowest minimum voltage that may be applied to the motors is 65VAC Running at lower voltage can cause premature failure to the motor For 3 phase...

Страница 3: ...del The control module features a 4 digit LED display that indicates demand of full speed and motor speed in rpm The display also indicates an error code message for minor diagnostics if required Moto...

Страница 4: ...itches are available for purchase as accessories No dampers can be used in the system RESTAURANT EXHAUST APPLICATION 1 Lock out all power sources 2 Inspect all fasteners and set screws and tighten as...

Страница 5: ...accident abuse neglect and operation not in accordance with instructions NOTICE No warranty claims will be honored by CANARM Ltd unless prior authorization is obtained Disconnect and secure to the OF...

Страница 6: ...concernant l usage de cet appareil car ils supplantent de manuel 9 Ne pas suivre les instructions de ce manuel peut causer de s rieuses blessures ou la mort due un choque lectrique ou aux pi ces en ro...

Страница 7: ...de ce niveau peut causer un d faillance pr matur e du moteur Pour un moteur 3 phases un entra nement fr quence variable VFD est requis pour ajuster la vitesse du moteur CONTR LE DE VITESSE VARIABLE U...

Страница 8: ...si n cessaire La vitesse du moteur peut tre chang e en ajustant le pot de contr le de la vitesse situ sur le module de contr le Un petit tournevis peut tre utilis pour faire cet ajustement M A2X FR_05...

Страница 9: ...OUVERTURE DU TOIT RECOMMAND E CONDUIT SOUD PAR AUTRUI CONDUIT SOUD PAR AUTRUI REBORD VENTIL MINIMUM DE 20 DE LA CIME DU TOIT C BL POUR TRE ALIMENT PAR D AUTRES MUR SURFACE DU TOIT INTERRUPTEUR DE FER...

Страница 10: ...ration excessif D bit d air r duit Mettre l appareil hors tension et fermer le disjoncteur avant de faire l inspection ou l entretien Un manque cette directive pourrait causer de s rieuses blessures o...

Отзывы: