11 Trouble Shooting 

  26 / 30 

 

F-104 

Inverter grid-connected 
relay fault 

Contact Customer service.   

F-105 

Grid frequency fault 

1. If power grid frequency returns to normal, the inverter 
will restore the grid connection automatically.   
2. If error message still exists, contact Customer service.   

F-106 

Grid voltage fault 

1. Turn off DC switch, remove AC connector, measure the 
voltage between fire line and the zero line, then check if it 
is consistent with the grid-connected specification of 
inverter. 
2. Inconsistent, check the grid layout. 
3. Consistent, connect the AC connector, turn on DC 
Switch, inverter will restore the grid connection 
automatically.   
4. If error message still exists, contact Customer service.   

F-107 

DC component over 
range 

1. Restart inverter. 
2. If error message still exists, contact Customer service. 

F-108 

Current sensor fault 

1. Wait until inverter restores normal work. 
2. If error message still exists, contact Customer service. 

F-110 

Leakage current 
detection unit fault 

1. Check if there is any PV cable breakage. 
2. Check if the PV modules grounding improperly.   
3. Restart inverter. 
4. If error message still exists, contact Customer service. 

F-111 

Leakage current fault 

1. Check if PV strings grounding properly.   
2. If error message still exists, contact Customer service. 

F-112 

DC insulation fault 

1. Check if inverter grounding properly. 
2. Check if the positive and negative poles of PV modules 
are short out to the PE cable. 
3. Wait until inverter restores normal work.   
4. If error message still exists, contact Customer service. 

F-113 

Leakage current 
detection consistency 
error (Major) 

1. Restart the inverter. 
2. If error message still exists, contact Customer service. 

F-114 

Frequency detection 
consistency error (Major) 

1. Restart the inverter. 
2. If error message still exists, contact Customer service. 

F-115 

Power grid voltage 
detection consistency 
error (Major) 

F-116 

Leakage current 
detection consistency 
error (Minor) 

F-117 

Frequency detection 
consistency error (Minor) 

Содержание CSI-3K-S22002-E

Страница 1: ...CSI 3K S22002 E CSI 5K S22002 E PV Inverter User Manual Part No 6431000401 Released Date August 2020...

Страница 2: ......

Страница 3: ...2 Operation requirements 3 2 2 3 Protecting labels 3 3 Product Overview 4 3 1 Product Introduction 4 3 2 Appearance 4 3 3 Product Nameplate 5 4 Storage 7 5 Unpackaging and Inspection 7 6 Installation...

Страница 4: ...nal 21 8 4 External WiFi 21 9 Commissioning Inverter 22 9 1 Checking Electrical 22 9 2 Checking Mechanical 22 9 3 Start UP Inverter 22 9 4 LED Indicators 23 9 5 Switch off 23 10 Daily Maintenance 24 1...

Страница 5: ...al is subject to change by Canadian Solar Inc without prior notice Canadian Solar Inc gives no warranty of any kind whatsoever either explicitly or implicitly with respect to the information contained...

Страница 6: ...ON indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE indicates a situation which if not avoided could result in equipment or prope...

Страница 7: ...ion and working principles of the grid tied PV system 2 2 2 Operation requirements Use the inverter in installations that meet the following specifications only 1 Permanent installation is required 2...

Страница 8: ...d the power into the power grid This document involves the following product models CSI 3K S22002 E CSI 5K S22002 E PV grid connected system mainly includes PV modules DC switch inverter AC switch ele...

Страница 9: ...Disconnect the DC current safely D CT Meter receptacle Connect CT or Meter E Waterproof and breathable valve F Communication port Connect wireless datalogger WiFi or GPRS RS485 G AC receptacle H Exte...

Страница 10: ...3 Product Overview 6 30 FIG 3 3 Inverter Nameplate for reference...

Страница 11: ...torage After long periods storage the inverters need to be inspected and tested by qualified persons before they are put into use 5 Unpackaging and Inspection Before unpacking the inverter check the p...

Страница 12: ...ors and outdoors 4 The humidity of the installation location should be below 100 without condensation 5 The ambient temperature should be between 25 C to 60 C 6 Install at eye level for easy operation...

Страница 13: ...n Clearance Requirement min 30c m min 50cm min 50cm min 30c m min 30c m min 30c m min 30c m min 30c m min 30c m min 30c m min 30c m min 50cm min 50cm min 50cm min 50cm min 50cm min 50cm min 50cm min 5...

Страница 14: ...s i e salt sulfur or ammonia areas which may affect the product warranty 6 2 Mounting Wall mounting Bracket Danger To avoid electrical shock or other injury please inspect existing electronic or plumb...

Страница 15: ...Must make sure the wall mounting bracket has mounted on the wall firmly before install inverter Installation steps 1 Hang the inverter on wall mounting bracket Keep balance during the operation to pre...

Страница 16: ...r 7 2 Network Diagram Electrical connections of inverter include grounding connection PV array connection AC connection and communication connection PV array Inverter Breaker Fuse Electricity meter FI...

Страница 17: ...ble with copper conductor 4 6mm2 10 14mm Signal cable Two cores cable 0 2 0 75mm2 24 18AWG 3 5 5 5mm PE cable Single core outdoor cable with copper conductor 4 6mm2 N A Note No cable is supplied 7 5 W...

Страница 18: ...r factor must comply with VDE AR N 4105 When using inverter comply with CEI 0 21 The total capacity of PV inverter is more than 3KW and less than or equal 6KW the inverter s displacement power factor...

Страница 19: ...AC Connector AC connectors have two types EXCEEDCONN type or DEVALAN type procedure steps as below 1 Strip the cable s jacket and then adjust the relative length of L N and PE cables to make the leng...

Страница 20: ...ype Torque 1 4N m L N PE B B B B N PE L FIG 7 9 AC Terminal Positions 3 Push the threaded sleeve into the socket element screw the press screw tightly EXCEEDCONN type DEVALAN type FIG 7 10 Tightening...

Страница 21: ...value of the inverter Note Consider temperature coefficient of the PV modules Check the inverter specification in section ANNEX B 7 72 Wiring There are two types of DC connectors MC4 H4 check the con...

Страница 22: ...Tighten the nut with a special wrench Torque 2 5 2 9 N m FIG 7 16 Insert the Contact FIG 7 17 Tighten the Cable Gland 5 Insert the assembled connectors into the bottom terminal of the inverter until...

Страница 23: ...Procedure steps DEVALAN and EXCEEDCONN types 1 Remove the signal cable s jacket by about 23mm and then strip the wire insulation layer by about 7mm 16 7 24 AWG FIG 7 20 Prepare the Signal Cable 2 Inse...

Страница 24: ...T 5 DEVALAN type EXCEEDCONN type FIG 7 21 Connector Positions 3 Screw the press screw tightly and then push the threaded sleeve into the socket 1 2 1 2 DEVALAN type EXCEEDCONN type FIG 7 22 Assembling...

Страница 25: ...via RS485 serial line and then connect this module to PC 8 3 External GPRS Optional The external GPRS communication module is used for remote monitoring More details for installation and operation me...

Страница 26: ...ers are sealed reliably which are used for the empty DC connectors 4 Ensure all the cables are connected effectively fixed firmly and no visible damages to the insulation layers 9 3 Start UP Inverter...

Страница 27: ...e contact the maintenance personnel Note For the monitoring and local APP information please refer to documents published on our website at https monitoring csisolar com platformSelect 9 4 LED Indicat...

Страница 28: ...ccessories and spare parts approved by the inverter manufacturer only Never modify the inverter or other components of the inverter The loss of any or all warranty rights may follow if otherwise NOTIC...

Страница 29: ...ase contact the dealer or Canadian Solar to replace a new one Errors as indicated in the table below Error Code Error Message Suggestion F 100 Over temperature 1 Check heatsink for obstructions ventil...

Страница 30: ...error message still exists contact Customer service F 110 Leakage current detection unit fault 1 Check if there is any PV cable breakage 2 Check if the PV modules grounding improperly 3 Restart inver...

Страница 31: ...described in section 10 and section 11 2 Remove all the connection cables from the inverter 3 Unscrew the fixing screws on both sides of the inverter 4 Remove the inverter from the bracket Note Befor...

Страница 32: ...eneral packet radio service LED light emitting diode MPPT maximum power point tracking PC personal computer PE protecting earthing PV photovoltaic RCD residual current protective device RCM residual c...

Страница 33: ...80 AC Nominal Frequency And Range Hz 50 60 5 Max Output Current A 13 6 25 Power Factor Rated Output Power 0 99 Displacement Power Factor 0 8 leading to 0 8 lagging Total Harmonic Distortion THDi 3 Eff...

Страница 34: ...rotection Degree IP65 Operating Ambient Temperature Range C 25 60 45 derating operation Relative Humidity Non Condensing 0 100 Max Operating Altitude m 4000 3000 derating operation Acoustic Noise Emis...

Страница 35: ...6 P 1 519 837 1881 F 1 519 837 2550 Sales Inquiries Email info canadiansolar com Customer Support Email service ca canadiansolar com This manual is subject to change without prior notification Copyrig...

Отзывы: