background image

7. Normal Operation

.35.

.34.

The following submenus are displayed when the Settings menu is selected:

1. Set Time

2. Set Address

7.3 Settings

7.3.1 Set Time

This function allows time and date setting. When this function is selected, the LCD will 

display a screen as shown in Figure 7.3.

NEXT=<ENT>  OK=<ESC>

01-01-2019  16:37

Figure 7.3 Set Time

Press the UP/DOWN keys to set time and data. Press the ENTER key to move from one 

digit to the next (from left to right). Press the ESC key to save the settings and return to 

the previous menu.

7.3.2 Set Address

This function is used to set the address when muti inverters are connected. 

The address number can be assigned from “01”to “99”(see Figure 7.4). The default address 

number of Canadian Solar Three Phase Inverter is “01”.

YES=<ENT>  NO=<ESC>

Set Address: 01

Figure 7.4 Set Address

Press the UP/DOWN keys to set the address. Press the ENTER key to save the settings. 

Press the ESC key to cancel the change and return to the previous menu.

7.2.1 Lock Screen

Pressing the ESC key returns to the Main Menu. Pressing the ENTER key locks 

(Figure 7.2(a)) or unlocks (Figure 7.2 (b)) the screen.

(b)

(a)

Figure 7.2 Locks and Unlocks the Screen of LCD

7. Normal Operation

I_DC01:   +05.0A
I_DC02:   +04.9A

...

I_DC20:   +05.2A

VPV_Total: Shows input voltage total. 

IPV_Total: Shows input current total. 

Table 7.1 Information list

Status:   Generating
Power:   1488W

Grid Frequency
F_Grid     50.06Hz

Total Energy
0258458  kwh

This Month: 0123kwh
Last Month: 0123kwh

Today:        15.1kwh 
Yesterday: 13.5kwh

10 sec

10 sec

10 sec

10 sec

10 sec

10 sec

Status: Shows instant status of the Inverter. 

Power: Shows instant output power value.

F_Grid: Shows the grid's frequency value.

Total generated energy value.

This Month: Total energy  generated this month.

Last Month: Total energy  generated last month.

Today: Total energy  generated today.

Yesterday: Total energy  generated yesterday.

Display

Duration

Description

Inverter

 

SN

00000000000000

10 sec

Display series number of the inverter.

10 sec

V_C: Shows the grid's voltage value.

I_C: Shows the grid's current value.

10 sec

V_A: Shows the grid's voltage value.

I_A: Shows the grid's current value.

Rea_Power:  000Var
App_Power:          VA

10 sec

Rea_Power: Shows the reactive power of the inverter. 

App_Power: Shows the apparent power of the inverter. 

Work Mode: Volt-watt
DRM NO.:08

10 sec

10 sec

Work Mode: Shows current working mode.  

DRM NO.: Shows DRM Number.  

I_DC01 : Shows input 01 current value. 

I_DC02 : Shows input 02 current value.

...

I_DC20 : Shows input 20 current value.

VPV_Total:   1000.0V
IPV_Total:      +99.0A

V_A:   345.7V
I_ A:    109.0A

V_C:   345.0V
I_ C:    109.8A

Содержание CSI-100K-T400

Страница 1: ...emea canadiansolar com Australia Canadian Solar MSS Australia Pty Ltd 44 Stephenson St Cremorne VIC 3121 Australia P 61 3 860 918 44 Sales Inquiries Email sales au canadiansolar com Customer Support...

Страница 2: ...38 7 4 9 Warning Message 38 7 5 Advanced Settings Technicians Only 39 7 5 1 Selecting Standard 39 7 5 2 Grid ON OFF 40 7 5 3 Clear Energy 40 7 5 4 Reset Password 41 7 5 5 Power control 41 7 5 6 Calib...

Страница 3: ...rnating current AC power that can satisfy local loads as well as feed the power distribution grid This manual covers the three phase inverter model listed below CSI 100K T400GL02 E CSI 110K T400GL02 E...

Страница 4: ...box to repackage the inverter seal with adhesive tape with the desiccant inside the box Store the inverter in a clean and dry place free of dust and dirt The storage temperature must be between 40 70...

Страница 5: ...e of the inverter heat sink can reach 75 The inverter is designed to work in an ambient temperature range between 25 to 60 If multiple inverters are installed on site a minimum clearance of 500 mm sho...

Страница 6: ...electricity supply the sound level from the inverter can be quite high 3 2 Product handling Figure 3 3 Handles used to move the inverter shown circled in red 3 1 2 4 Air circulation Do not install in...

Страница 7: ...r shall be mounted vertically The steps to mount the inverter are listed below 1 Refer to Figure 3 6 drill holes for mounting screws based on the hole diameter of bracket using a precision drill keepi...

Страница 8: ...es from vertical Figure 3 10 Wrong installation Angle The steps to mounted to the rack are listed below 3 Install mounting plate 1 Remove the bracket and fasteners from the packaging Mark the position...

Страница 9: ...FF 2 Switch the DC Isolator OFF 3 Connect the inverter to the grid 4 Assemble PV connector and connect to the Inverter Inverter design uses PV style quick connect terminal The top cover needn t to ope...

Страница 10: ...ding 2 Prepare OT terminals M10 To effectively protect the inverter two grounding methods must be performed Connect the AC grounding cable Please refer to section 3 4 3 Connect the external grounding...

Страница 11: ...ING MAKE SURE the polarity of the PV array output conductors matches the DC and DC terminal labels before connecting these conductors to the terminals of the inverter 5 Measure PV voltage of DC input...

Страница 12: ...ion device must be used between the inverter and the grid NOTE Use AL CU transfer bi metallic terminal or anti oxidant grease with aluminum cables and terminals Table 3 2 Rating of grid OCPD 3 4 3 1 C...

Страница 13: ...socket wrench Tighten the screws on the terminal block The torque is 10 20 Nm Figure 3 27 wiring with Neutral CSI 100 110 K T400GL02 E Figure 3 28 wiring without Neutral CSI 125K T500GL02 E Cable spec...

Страница 14: ...munication terminals on the inverters COM1 is a 4 pin connector reserved for WiFi Cellular datalogger COM2 and COM3 are RS485 connection between inverters and both RJ45 and Terminal block are provided...

Страница 15: ...the display select ENTER There are 4 sub menu options use the UP DOWN arrows to highlight ADVANCED SETTINGS Press enter to select Information See overview Menu on page 33 2 The screen will show that...

Страница 16: ...reverse polarity may damage these protection circuits and or the inverter 5 4 3 2 Leakage to ground 5 4 3 2 1 Detection of leakage to ground Canadian Solar inverters are transformer less and do not h...

Страница 17: ...ocedure To stop the inverter it is mandatory that the steps below are followed in the exact order outlined 1 Switch AC switch OFF 2 Wait approximately 30 seconds during this time the AC side capacitor...

Страница 18: ...l Operation I_DC01 05 0A I_DC02 04 9A I_DC20 05 2A VPV_Total Shows input voltage total IPV_Total Shows input current total Table 7 1 Information list Status Generating Power 1488W Grid Frequency F_Gri...

Страница 19: ...aintaince person to get running message such as internal temperature Standard No 1 2 etc Screens can be scrolled manually by pressing the UP DOWN keys 7 4 Advanced Info Technicians Only NOTE To access...

Страница 20: ...on the limits can be changed manually These voltage values are the phase voltage The display shows the latest warn messages see Figure 7 15 Screens can be scrolled 100 manually by pressing the UP DOWN...

Страница 21: ...Press the UP key to revise the value Press the ENTER key to execute the setting Press the ESC key to return to the previous menu OV G V1 300 480V OV G V1 T 0 01 9S OV G V2 300 490V OV G V2 T 0 01 1S...

Страница 22: ...de Settings 1 Working Mode Set 2 Power Rate Limit 3 Freq Derate Set 4 10mins Voltage Set 5 Power Priority 6 Initial Settings 7 Voltage PCC Set Selecting STD Mode Settings displays the sub menu shown b...

Страница 23: ...ded Power Parameter and Voltage Parameter YES ENT NO ESC Power para 1 000 7 5 13 Debug Parameter 7 5 14 FAN Test This section is applicable to maintenance personnel only Figure 7 24 Debug Parameter as...

Страница 24: ...module will start creating 450 Vdc between PV and ground No need any control or settings The integrated Anti PID module repairs the PID effect of the PV model at night When operating the inverter LCD...

Страница 25: ...age OV G V01 02 03 04 OV G F01 02 UN G F01 02 G IMP NO GRID OV DC01 02 03 04 OV BUS UN BUS01 02 GRID INTF01 02 OV TEM Failure description Over grid voltage Under grid voltage Over grid frequency Under...

Страница 26: ...status of the LED status indicator lights Other readings obtained from the Information submenu refer to Section 6 2 will also be helpful 5 The PV array configuration e g number of panels capacity of p...

Страница 27: ...unication connections MC4 connector OT Terminal max 185 mm LCD 2 20 Z RS485 Optional Wifi GPRS PLC 3 N PE 220 380 230 400 Dimensions W H D Weight 84kg Max DC input voltage Volts MPPT voltage range Vol...

Отзывы: