background image

www.canadiansolar.com

| 11

· 

Do not

 make modifications to the PV components 

(diode, junction box, plug connectors).   

·  Regular maintenance is required to keep modules 

clear of snow, bird droppings, seeds, pollen, 
leaves, branches, dirt spots, and dust.  

·  Modules with sufficient tilt (at least 15°), generally do 
    not require cleaning (rain will have a self-cleaning 

effect). If the module has become soiled, it shall be 
washed with water and a non-abrasive cleaning 
implement (sponge) during the cool part of the day. 
Do not scrape or rub dry dirt away, as this may cause 
micro scratches.

·  Snow should be removed using a soft brush.

·  The system shall be periodically inspected to verify 
   the integrity of all wiring and supports.

·  To protect against electric shock or injury, electrical 

or mechanical inspections and maintenance 
should be performed by qualified personnel only 
and on a regular basis.

·  Please refer to our Installation Manual Annex 

(Section Annex D: Module Cleaning Guide) for 
more information on module cleaning.

AMENDED EDITIONS 

AND DATES

·  The first edition Rev 1.1 was released in Jan, 2009.
·  Rev 2.1 was amended and released in Jan, 2011.
·  Rev 2.2 was amended and released in Apr, 2012.
·  Rev 2.3 was amended and released in Sep, 2012.
·  Rev 2.4 was amended and released in May, 2013.
·  Rev 3.1 was amended and released in Apr, 2014.
·  Rev 3.2 was amended and released in Dec, 2015.
·  Rev 3.3 was amended and released in Mar, 2015.
·  Rev 3.4 was amended and released in Mar, 2016.
·  Rev 3.5 was amended and released in June, 2016.
·  Rev 3.6 was amended and released in Mar, 2017.

7.0 

MAINTENANCE

CANADIAN SOLAR INC.

545 Speedvale Avenue West, Guelph, Ontario, Canada N1K 1E6

www.canadiansolar.com

Содержание CS6A-M

Страница 1: ...INSTALLATION MANUAL OF STANDARD SOLAR MODULES IEC For professional use only...

Страница 2: ...1 2 LIMITATION OF LIABILITY 2 0 SAFETY PRECAUTIONS 3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 0 UNPACKING AND STORAGE 5 0 MODULE INSTALLATION 5 1 MODULE WIRING 5 2 GROUNDING 6 0 MOUNTING INSTRUCTIONS...

Страница 3: ...or document the English version shall prevail and take control in all respects 1 2 LIMITATION OF LIABILITY Canadian Solar Inc shall not be held responsible for damages of any kind including without l...

Страница 4: ...racteristics of Canadian Solar Inc crystalline silicon PV modules can be found in our Installation Manual Annex Section Annex C Module Specifications on www canadiansolar com Main electrical character...

Страница 5: ...racks at cell level which in turn may compromise module reliability Do not carry modules on your head Do not drop or place objects such as tools on the modules Do not lift modules by their wires or ju...

Страница 6: ...ins sea spray Exposing modules to salt i e marine environments or sulfur i e sulfur sources volcanoes incurs the risk of module corrosion Failure to comply with these instructions will void Canadian S...

Страница 7: ...lled but the system has not been connected to the grid yet each module string should be kept under open circuit conditions and proper actions should be taken to avoid dust and moisture penetration ins...

Страница 8: ...www canadiansolar com It is not possible to use standard grounding methods for certain module ranges Please refer to Annex B for more details GROUNDING METHOD BOLT TOOTHED NUT CUP WASHER A grounding k...

Страница 9: ...erial Canadian Solar Inc recommends bars with a minimum thickness of 50 mm 1 97 in The support bar centerline should be positioned within 100 mm 3 94 in of the side frame centerline slight shifts may...

Страница 10: ...imum Load Uplift load 2400 Pa Downforce load 5400 Pa Compatible module type CS6A P CS6A M CS6V P CS6V M CS6P P CS6P M CS6K P CS6K M CS6X P CS6X M CS6K MS CS6V MS and CS6A MS Bolting on long frame side...

Страница 11: ...ctric shock or injury electrical or mechanical inspections and maintenance should be performed by qualified personnel only and on a regular basis Please refer to our Installation Manual Annex Section...

Отзывы: