Model Type 

Maximum 

power 

Pmax <W> 

Operating 

voltage 

Vmp <V> 

Operating 

current 

Imp <A> 

Open 

Circuit 

Voltage 
Voc <V> 

Short 

Circuit 

Current 

Isc <A> 

Max. Series 

Fuse 

Rating 

<A> 

Overall Dimension   

<mm> 

Weight 

<Kg> 

CS6AH-230M 

230   

24.1   

9.55   

28.7   

10.15   

20   

CS6AH-235M 

235   

24.5   

9.60   

29.0   

10.21   

20   

CS6PH-240P 

240   

28.2   

8.52   

33.8   

9.41   

20   

1638 x 982 x 

40/35 

19.00 

CS6PH-245P 

245   

28.4   

8.63   

34.0   

9.48   

20   

CS6PH-250P 

250   

28.6   

8.75   

34.2   

9.55   

20   

CS6PH-255P 

255   

28.8   

8.86   

34.4   

9.62   

20   

CS6PH-260P 

260   

29.0   

8.97   

34.6   

9.69   

20   

CS6PH-265P 

265   

29.2   

9.08   

34.8   

9.76   

20   

CS6PH-270P 

270   

29.4   

9.19   

35.0   

9.83   

20   

CS6PH-275P 

275   

29.6   

9.30   

35.2   

9.90   

20   

CS6PH-280P 

280   

29.8   

9.40   

35.4   

9.97   

20   

CS6PH-280M 

280   

30.0   

9.34   

36.5   

9.96   

20   

1638 x 982 x 

40/35 

19.00 

CS6PH-285M 

285   

30.3   

9.41   

36.7   

10.02   

20   

CS6PH-290M 

290   

30.6   

9.48   

36.9   

10.08   

20   

CS6PH-295M 

295   

30.9   

9.55   

37.1   

10.14   

20   

CS6PH-300M 

300   

31.2   

9.62   

37.3   

10.19   

20   

CS6PH-305M 

305   

31.5   

9.69   

37.5   

10.25   

20   

CS6PH-310M 

310   

31.8   

9.75   

37.7   

10.31   

20   

CS6XH-345M 

345   

36.5   

9.46   

44.4   

9.94   

20   

1954x 982 x 

40/35 

23.00 

CS6XH-350M 

350   

36.8   

9.52   

44.6   

10.00   

20   

CS6XH-355M 

355   

37.1   

9.57   

44.8   

10.06   

20   

CS6XH-360M 

360   

37.4   

9.63   

45.0   

10.12   

20   

CS6XH-365M 

365   

37.7   

9.69   

45.2   

10.18   

20   

CS6XH-370M 

370   

38.0   

9.74   

45.4   

10.24   

20   

CS6XH-375M 

375   

38.3   

9.80   

45.6   

10.30   

20   

CS6XH-295P 

295   

34.4   

8.58   

41.4   

9.52   

20   

1954x 982 x 

40/35 

23.00 

CS6XH-300P 

300   

34.6   

8.68   

41.6   

9.56   

20   

CS6XH-305P 

305   

34.8   

8.77   

41.8   

9.60   

20   

CS6XH-310P 

310   

35.0   

8.86   

42.0   

9.64   

20   

CS6XH-315P 

315   

35.2   

8.95   

42.2   

9.68   

20   

CS6XH-320P 

320   

35.4   

9.04   

42.4   

9.72   

20   

CS6XH-325P 

325   

35.6   

9.13   

42.6   

9.76   

20   

CS6XH-330P 

330   

35.8   

9.22   

42.8   

9.83   

20   

CS6XH-335P 

335   

36.0   

9.31   

43.0   

9.90   

20   

CS6XH-340P 

340   

36.2   

9.40   

43.2   

9.97   

20   

CS6XH-345P 

345   

36.4   

9.49   

43.4   

10.04   

20   

All manuals and user guides at all-guides.com

Содержание CS5AH

Страница 1: ...For professional use only INSTALLATION MANUAL OF REPLACEMENT SOLAR MODULES All manuals and user guides at all guides com...

Страница 2: ...0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 4 0 UNPACKING AND STORAGE 5 5 0 MODULE INSTALLATION 6 5 1 MODULE WIRING 8 5 2 GROUNDING 9 6 0 MOUNTING INSTRUCTIONS 10 6 1 MOUNTING METHOD BOLTING 10 6 2 MOUN...

Страница 3: ...damages of any kind including without limitation bodily harm injury or damage to property in connection with handling PV modules system installation or compliance or non compliance with the instructi...

Страница 4: ...a thin solder coating layer that contains lead CAS no 7439 92 1 Under normal or reasonably foreseeable conditions of use exposure to the lead that is contained in our solar modules can be excluded How...

Страница 5: ...ng to engineering optimization and approval of project specific module string lengths 4 0 UNPACKING AND STORAGE PRECAUTIONS Modules should be stored in a dry and ventilated environment to avoid direct...

Страница 6: ...ian solar modules have been qualified for Application Class A equivalent to Safety Class II requirements Modules rated under this class should be used in systems operating at voltage above 50V or powe...

Страница 7: ...e wired in series to increase voltage or in parallel to increase current To connect modules in series connect the cables from the positive terminal of one module to the negative terminal of the next m...

Страница 8: ...ndicates that there is a wiring fault When modules have been pre installed but the system has not been connected to the grid yet each module string should be kept under open circuit conditions and pro...

Страница 9: ...nded and that module installation should comply with all applicable local electrical codes and regulations Grounding connections should be installed by a qualified electrician Connect module frames to...

Страница 10: ...ional holes or modify the module frame Doing so will void the warranty Classic modules can be installed in either landscape or portrait orientations Refer to the detailed instructions for further guid...

Страница 11: ...Middle four holes installation method A Short frame four holes installation method B Inner four holes installation method B Middle four holes installation method B Installation Method Module Types Sho...

Страница 12: ...stem designer and installer are responsible for load calculations and for proper design of support structure Canadian Solar s warranty may be void in cases where improper clamps or unsuitable installa...

Страница 13: ...400 5400 2400 5400 3600 A1 Range mm CS5AH 220 380 330 400 CS5PH 220 390 330 400 CS6AH CS6A P PLUS 220 440 270 330 CS6PH CS6P P PLUS 0 239 331 550 240 330 CS6XH CS6X P PLUS 340 550 410 490 6 2 2 Four c...

Страница 14: ...ww csisolar com 6 2 3 Four clamps on long side of frame and rails parallel to the long side frame Module Types Max Mechanical Load Pa 4000 2400 5400 2400 A1 Range mm CS6PH CS6P P PLUS 240 330 CS6XH CS...

Страница 15: ...thods are found When installing insertion profiles please take the following measures into account 1 Do not bend the module frame 2 Do not touch the front glass or cast shadow onto it 3 Do not damage...

Страница 16: ...have to be located under the modules the gap H between the frame and the racking structure should be at least 25mm If your tracker design cannot meet the above distance requirement please contact Can...

Страница 17: ...racked or broken modules represent an electric shock hazard due to leakage currents and the risk of shock is increased when modules are wet Before cleaning thoroughly inspect modules for cracks damage...

Страница 18: ...adian Solar recommends cleaning the soft dirt like dust on modules just with air pressure This technique can be applied as long as the method is efficient enough considering the existing conditions Me...

Страница 19: ...CS5AH 210M 210 41 6 5 07 49 4 5 38 15 CS5PH 235P 235 50 8 4 63 62 6 4 93 15 1602 x 1061 x 40 35 20 30 CS5PH 240P 240 51 0 4 71 62 8 5 00 15 CS5PH 245P 245 51 4 4 79 63 0 5 07 15 CS5PH 250P 250 51 4 4...

Страница 20: ...9 41 36 7 10 02 20 CS6PH 290M 290 30 6 9 48 36 9 10 08 20 CS6PH 295M 295 30 9 9 55 37 1 10 14 20 CS6PH 300M 300 31 2 9 62 37 3 10 19 20 CS6PH 305M 305 31 5 9 69 37 5 10 25 20 CS6PH 310M 310 31 8 9 75...

Страница 21: ...70M PLUS 270 48 0 5 63 57 7 5 98 20A CS6A 210P PLUS 210 24 5 8 58 29 7 9 17 20A 1324 x 982 x 40 35 15 50 CS6A 215P PLUS 215 24 7 8 71 29 9 9 23 20A CS6A 220P PLUS 220 24 9 8 84 30 1 9 29 20A CS6A 225P...

Страница 22: ...TIONS AND DATES Rev 1 0 was amended and released on October 2020 Rev 1 1 was amended and released on December 2020 Rev 1 2 was amended and released on March 2021 CSI Solar Co Ltd 199 Lushan Road SND S...

Отзывы: