Fill it up!

Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow

as much air as possible to escape from the plumbing and the control system during the filling process.

After turning the power on at the main power panel, the top-side panel display will go through specific sequences. These

sequences are normal and display a variety of information regarding the configuration of the Swim Spa control.

Priming Mode - MO19*

This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.

Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will

automatically starts normal heating and filtering at the end of the priming mode. During the priming mode, the heater is

disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or

no-flow conditions. Nothing comes on automatically, but the pump can be energized by pushing the “Jets”

or “Aux” buttons.

Priming the Pump

As soon as the above display appears on the panel, push the “Jets” button once to start the Pump in low-speed and then again 

to switch to high-speed. will now be running in high-speed to facilitate priming. If the pump has not primed after 2 minutes, and 

water is not flowing from the jets in the spa, do not allow the pump to continue to run. Turn off the pump and repeat the process. 

Note: Turning the power off and back on again will initiate a new pump priming session. Sometimes momentarily turning the 

pump off and on will help it to prime. Do not do this more than 5 times. If the pump will not prime, shut off the power to the spa 

and call for service.

Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should

a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to

the pump and cause the system to energize the heater and go into an overheat condition.

Exiting Priming Mode

You can manually exit Priming Mode by pressing the “Warm” or “Cool” button. Note that if you do not manually exit the

priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. Be sure that the

pump have been primed by this time. Once the system has exited Priming Mode, the top-side panel will momentarily display the 

set temperature but the display will not show the water temperature yet, as shown below.

This is because the system requires approximately 

1 minute of water flowing through the heater to 

determine the water temperature and display it.

R U N

P M P 5

P U R G

A I R

- - - -

- - - C

Ready Mode and Rest Mode 

In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is

known as the “primary pump.”

Primary pump is a 2-Speed Pump 1, Ready Mode (indicated by     ) will circulate water periodically, using Pump 1

Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display. 

This is known as “polling.”

Rest Mode (indicated by     ) will only allow heating during programmed filter cycles. Since polling does not occur, the

temperature display may not show a current temperature until the primary pump has been running for a minute or two.

In Rest Mode, the spa will only heat to set temperature during programmed filter times.

Water Temperature Setting 

Содержание St Lawrence 13' Swim Spa

Страница 1: ...W R E N C E 1 3 S W I M S PA St Lawrence 13 Swim Spa Owners Manual 390 x 228 x 137 cm 154 x 90 x 54 KS 10004 For Service Support please contact us anytime support canadianspacompany com canadianspacom...

Страница 2: ...nths to make sure that the unit is operating properly 14 CAUTION Do not operate audio video controls while inside the spa 15 Installation of the spa for other than a residential dwelling will result i...

Страница 3: ...organic material such as body oils dead skin cells and hair DRAIN VALVE Valve located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQ...

Страница 4: ...n please ask before ground construction and the delivery of your spa Your spa must be sited on a solid flat level base which is the same size or larger than the spa The base can be either a 10 15cm co...

Страница 5: ...To access the Control Pack undo the 4 screws on both panel strips Installation Electrical power requirements Power connections Single Phase A is the normal wiring configuration for most household ele...

Страница 6: ...mber in the sequence is the incoming power meter which can be used to verify that the spa is wired correctly 2 The spa begins an automatic priming routine which will last 6 minutes Pr is on the LED di...

Страница 7: ...nd it will tell you what to add and how much KA 10052 Spa Flush Annually flush the spa to remove bio film that has attached to the interior of the spa pipes KA 10164 2 Pump Control System TP600 Initia...

Страница 8: ...ing an air lock This normal occurrence can be easily corrected by loosening the plumbing union on the suction side of the Jet or Pump until water flows into the pump and all air is expelled PRESS BUTT...

Страница 9: ...t See common water problem section Settings 2 x Pumps standard Simple Options Press Menu Temp Up then Light button until you reach the mode you require TEMP Temp Up button until arrow is either pointi...

Страница 10: ...entarily turning the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be...

Страница 11: ...t but since the spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments...

Страница 12: ...the filter Hold Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this f...

Страница 13: ...water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater t...

Страница 14: ...Residual Current Device RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the RCD associated with the Swim S...

Страница 15: ...r maintenance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS...

Отзывы: