O K A N A G A N / S A S K A T O O N S P A S
Temp/Set (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100F°/37°C. The last
measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is
current only when the pump has been running for at least
2 minutes.
To display the set temperature, press the “Warm” button once.
To change the set temperature, press the pad a second time
before the LCD stops flashing. Each press of the “Warm” or
“Cool” button will either raise or lower the set temperature.
After three seconds, the LCD will stop flashing and display the
current spa temperature.
Jets
Touch the “Jets” button once to activate the low speed of the
pump and again for the high speed. Press the “Jets” button
again to turn off the pump. If left running, the low speed of
the pump will automatically turn off after 4 hours, and the high
speed will automatically turn off after 15 minutes. It may also
activate for at least 2 minutes every 30 minutes to detect the
spa temperature and then to heat to the set temperature if
needed, depending upon mode. When the low speed turns on
automatically, it cannot be deactivated from the panel;
however, the high speed may be started.
Light
Press the “Light” button to turn the light on and off. If left on,
the light automatically turns off after 4 hours.
Mode
Mode is changed by pressing the “Warm” button, then pressing
the “Light” button.
Standard Mode
is programmed to maintain the desired
temperature. Note that the last measured spa temperature
displayed is current only when the pump has been running for
at least 2 minutes. “St” will be displayed momentarily when
you switch into Standard Mode.
Economy Mode
heats the spa to the set temperature only
during filter cycles. “Ec” will display solid when temperature is
not current, and will alternate with temperature when
temperature is current.
Sleep Mode
heats the spa to within 20°F/10°C of the set
temperature only during filter cycles. “FC” will display solid
when temperature is not current, and will alternate with
temperature when temperature is current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is
energized. The second filter cycle begins 12 hours later. Filter
duration is programmable for 2, 4, 6, 8 hours or for continuous
filtration (indicated by “FC”). The default filter time is 2 hours.
To program, press “Warm” button then “Jets.” Press “Warm to
adjust. Press “Jets” to exit programming.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C
within the heater, the pump will automatically activate to
provide freeze protection. The equipment stays on until 4
minutes after the sensors detect that the spa temperature
has risen to 45°F/7.2°C or higher.
VL260 Control Reference Card
Initial Start-up
When your spa is first actuated, it will go into Priming mode, indicated by “Pr”. The Priming mode will last for less than 5 minutes
and then the spa will begin to heat and maintain the water temperature in the Standard mode. Press the “Warm” button to skip
Priming Mode if desired.
(7)