Canadian Spa Calgary TP500 Скачать руководство пользователя страница 12

C A L G A R Y   T P 5 0 0

C A L G A R Y   T P 5 0 0

(22)

(23)

Filter Cycle 2 
Optional Filtration

Filter Cycle 2 is OFF by 

default. 

It is possible to 

overlap Filter Cycle 1 

and Filter Cycle 2, 

which will shorten 

overall filtration by the 

overlap amount.

Sub-Menu Detail – Set Filter Cycle 1

Purge Cycles

In order to maintain 

sanitary conditions, the 

pump will purge water 

from their respective 

plumbing by running 

briefly at the beginning of 

each filter cycle. 

If Filter Cycle 1 is set for 

24 hours, enabling Filter 

Cycle 2 will initiate a 

purge when Filter Cycle 2 

is programmed to begin.

Sub-Menu Detail – STANDBY FOR 1 HR

04-11-09

Adjusting Filtration

Main Filtration

Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of the 

display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calculates the 

end time and displays it automatically.

Hold Mode –
MO37  

Hold Mode is used 

to disable the pump 

during service 

functions like 

cleaning or replacing 

the filter. Hold Mode 

will last for 1 hour 

unless the mode is 

exited manually.

Drain Mode

Some spas have a 

special feature that 

allows a pump to be 

employed when 

draining the water. 

When available, this 

feature is a component 

of Hold Mode. Drain 

Mode will time out 

with Hold Mode.

Sub-Menu Detail – User Preferences

05-15-09

Preferences

F / C

 

 (Temp Display)

Change the temperature between Fahrenheit and Celsius.  

12 / 24 

 

(Time Display)

Change the clock between 12 hr and 24 hr display.

RE-MIN-DER

S  

(Reminders)

Turn the display of reminder messages (like “Clean Filter”) On or Off.

Note: Reminders continue to run in the background even when not displayed. So turning the display of Reminders On or Off does 

not reset any Reminder counts.

CLN-UP

  

(Cleanup)

Cleanup Cycle Duration is not always enabled, so it may not appear. When it is available, set the length of time Pump 1 will run 

after each use. 0-4 hours are available.

Additional Utilities

Utilities 

In addition to INFO, The Utilities Menu contains the following:

A / B

 (

A/B Sensor Temperatures)

When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater. 

FALT LOG

 

(Fault Log)

The Fault Log is a record of the last 24 faults that can be reviewed by a service tech.

Содержание Calgary TP500

Страница 1: ...C A L G A R Y T P 5 0 0 Calgary UV Spa Owners Manual TP500 210 x 153 x 79cm 83 x 61 x 32 KH 10037 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Страница 2: ...ill result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa c...

Страница 3: ...ozzle The jet can be removed by turning it counter clockwise To replace the jet push inward and clockwise until it clicks into place 5 Jumbo Directional jet Adjustable and interchangeable jet features...

Страница 4: ...of the above measurements Always consider during your planning that any decking boards and supporting beams that you install allow access to the sides of your Spa It is the customers responsibility t...

Страница 5: ...normal wiring configuration for most household electrical installations 3 wires live neutral and earth If however you have insufficient Amps you will need to use other connection see below Single Pha...

Страница 6: ...available The spa will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay part...

Страница 7: ...ive press will alternate through different lighting modes and colours TEMPERATURE UP TEMPERATURE DOWN Chlorine Granules Disinfection To protect your health ensure that your spa water is disinfected th...

Страница 8: ...Guides on Canadian Spa Company channel pH LOW pH HIGH pH NORMAL 7 2 7 6 Reduced ef cacy of disinfection Corrosion of metals Skin eye irritation Unpleasant odour Reduced ef cacy of disinfection Skin ey...

Страница 9: ...omponent See elimination test section Heater not operating or spa not heating Temperature set to low Set temperature above current water temperature Water level too low Add water until water level is...

Страница 10: ...ng the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to ru...

Страница 11: ...he spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the p...

Страница 12: ...the filter Hold Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this f...

Страница 13: ...o start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa is...

Страница 14: ...5 Massage Jet KK 10051 10 Waterfall KK 10155 Bread Pillow KK 010145 Fixed Speaker KK 10862 4 hp 2 6 x 2 2 speed Pump KK 10319 Filter Lid for skimmer KK 108581 SCF filter lid screws 2 per lid KK 10859...

Страница 15: ...tenance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND L...