6.2 MOUNTING METHOD: CLAMPING 

 

The mechanical load test with these mounting methods 
were performed according to IEC 61215. 

 

Top  or  bottom  clamping  methods  will  vary  and  are 
dependent on the mounting structures. Please follow 
the  mounting  guidelines  recommended  by  the 
mounting system supplier. 

 

Each module must be securely fastened at a minimum 
of four points on two opposite sides. The clamps should 
be  positioned  symmetrically.  The  clamps  should  be 
positioned according to the authorized position ranges.   

 

Install and tighten the module clamps to the mounting 
rails using the torque stated by the mounting hardware 
manufacturer. M8 X 1.25 (5/16”) bolt and nut are used 
for this clamping method.   

 

Tightening  torques  should  be  within  16~20  Nm 
(11.8~14.75  ft-lbs)  for  M8  (5/16”)  coarse  thread  bolts, 
depending  on  the  bolt  class.  For  the  bolt  grade,  the 
technical guideline from the fastener suppliers should 
be followed. Different recommendations from specific 
clamping hardware suppliers should prevail.   

 

The system designer and installer are responsible for 
load  calculations  and  for  proper  design  of  support 
structure.   

 

Canadian Solar’s warranty may be void in cases where 
improper clamps or unsuitable installation methods are 
found.  When  installing  inter-modules  or  end-type 
clamps,  please  take  the  following  measures  into 
account: 

1.

 

Do not bend the module frame. 

2.

 

Do not touch or cast shadows on the front glass. 

3.

 

Do  not  damage  the  surface  of  the  frame  (to  the 
exception of the clamps with bonding pins). 

4.

 

Ensure the clamps overlap the module frame by at 
least 10 mm (0.4 in) for CS6W, CS7N and CS7L, 5mm 
(0.2in) for others. 

5.

 

Overlap in length by at least 

a)

 

80  mm  (3.15  in)  when  uplift  load  >  2400  Pa  is 
required. 

b)

 

40  mm  (1.57  in)  when  uplift  load  ≤  2400  Pa  is 
required.   

6.

 

Ensure the clamp thickness is at least 3 mm (0.12 in). 

 

 

Clamp material should be anodized aluminum alloy or 
stainless steel. 

 

Clamp  positions  are  of  crucial  importance  for  the 
reliability of the installation. The clamp centerlines must 
only be positioned within the ranges indicated in table 
below,  depending  on  the  configuration  and  load.  For 
configurations where the mounting rails run parallel to 
the frame, precautions should be taken to ensure the 
bottom flange of the module frame overlaps the rail by 
15 mm (0.59 in) or more. 

 

 

 

Содержание Standard CS3U-P

Страница 1: ...For professional use only INSTALLATION MANUAL OF STANDARD SOLAR MODULES...

Страница 2: ...E REACH REGULATION 4 3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 4 0 UNPACKING AND STORAGE 5 5 0 MODULE INSTALLATION 6 5 1 MODULE WIRING 8 5 2 GROUNDING 11 6 0 MOUNTING INSTRUCTIONS 12 6 1 MOUNTING MET...

Страница 3: ...fferent language versions of this document the English version shall prevail Please refer to our product lists and documents published on our website at http www csisolar com as these lists are update...

Страница 4: ...rt 33 of Regulation EC No 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction of Chemicals REACH establishi...

Страница 5: ...lternatively a more accurate correction factor for the open circuit voltage can be calculated using the following formula Voc T C is the lowest expected ambient temperature at the system installation...

Страница 6: ...unauthorized chemical substance e g oil lubricant pesticide etc PRODUCT IDENTIFICATION Each module has three identical barcodes one in the laminate under the front glass the second on the rear side of...

Страница 7: ...s Do not immerse modules in water or constantly expose modules to water either fresh or salt i e from fountains sea spray Exposing modules to salt i e marine environments or sulfur i e sulfur sources...

Страница 8: ...for thermal expansion of the frames The small drainage holes on the underside of the module must not be blocked OPTIMUM ORIENTATION AND TILT To maximize the annual yield please calculate the optimum o...

Страница 9: ...hs to match various system configurations Recommended system cable schemes are shown in table 2 3 below Table 2 System Cable Scheme for CS3U CS3K CS3W CS3L CS3LA CS3LB CS3Y CS3N CS3S CS3SA CS6W CS7N C...

Страница 10: ...te Adjacent two modules left to right need to be rotated 180 degrees Portrait one row installation Note Adjacent two modules left to right need to be rotated 180 degrees Landscape installation Note Ad...

Страница 11: ...nt cable ties Protect exposed cables from damage by taking appropriate precautions e g placing them inside a metallic raceway like EMT conduit Avoid exposure to direct sunlight A minimum bending radiu...

Страница 12: ...ule without a frame laminate shall not be considered to comply with the requirements of UL 1703 or UL 61730 unless the module is mounted with hardware that has been tested and evaluated with the modul...

Страница 13: ...structural engineer 6 1 MOUNTING METHOD BOLTING The mechanical load test with these mounting methods were performed according to IEC 61215 Modules should be bolted to supporting structures through the...

Страница 14: ...lation method A Inner four holes installation method B Middle four holes installation method A Middle four holes installation method B Outer four holes installation method A CS1V CS1VL CS1A CS3K CS6A...

Страница 15: ...ystem designer and installer are responsible for load calculations and for proper design of support structure Canadian Solar s warranty may be void in cases where improper clamps or unsuitable install...

Страница 16: ...00 2400 2400 3600 2400 5400 2400 5400 3600 7000 5400 A1 Range mm CS1H 0 219 220 440 270 330 CS6A CS6VL CS1VL CS1HA CS1A 0 219 220 440 270 330 CS1V 0 239 331 550 240 330 CS3K CS6K CS1K CS6V 0 239 331 5...

Страница 17: ...mm 0 200 200 250 Max Mechanical Load Pa CS3U CS6U 1200 1200 1400 1400 CS3W 1000 1000 1200 1200 CS3L 2000 2000 2200 2200 CS1Y 1600 1600 1800 1800 CS3N 1400 1400 1600 1600 6 2 3 Four clamps on long side...

Страница 18: ...pes Max Mechanical Load Pa 2400 2400 A1 Range mm A2 Range mm CS3U CS6U 300 550 200 250 CS3K 100 550 200 250 6 2 5 Four clamps on short side of frame and rails parallel to the long side frame Module Ty...

Страница 19: ...Load Pa 2000 2000 2200 2200 2400 2400 A2 Range mm CS1VL CS1A CS1HA CS6A CS6VL 0 250 CS1V CS6V 0 210 CS3K 0 200 200 250 6 2 6 Four clamp mounting on short side of frame and an additional support bar p...

Страница 20: ...orce Uplift CS3K CS6K CS1K CS1H 72 inches 1 83 m 24 inches 0 61 m 2200 Pa 1400 Pa 64 inches 1 63 m 21 3 inches 0 54 m 2400 Pa 1400 Pa 48 inches 1 22 m 16 inches 0 41 m 3400 Pa 1800 Pa 32 inches 0 81 m...

Страница 21: ...hes 0 41 m 1800 Pa 800 Pa 32 inches 0 81 m 10 7 inches 0 27 m 1800 Pa 1200 Pa 24 inches 0 61 m 8 inches 0 2 m 1800 Pa 1800 Pa CS1Y 48 inches 1 22 m 16 inches 0 41 m 1800 Pa 1800 Pa 32 inches 0 81 m 10...

Страница 22: ...rtion profiles please take the following measures into account 1 Do not bend the module frame 2 Do not touch the front glass or cast shadow onto it 3 Do not damage the surface of the frame 4 Ensure th...

Страница 23: ...ntact Canadian Solar technical support department in writing for advices Tracker 1P Bolting method Install and tighten the module clamps to the mounting rails using the torque stated by the mounting h...

Страница 24: ...g hole location Plain washer outer diameter mm Test load Pa CS3W P CS3W MS A1 A3 400 B1 B3 1155 B1 B2 A3 A4 18 1800 1600 B1 B2 B3 B4 18 2400 2200 CS3W P CS3W MS A1 A3 400 B1 B3 1155 B1 B2 A3 A4 18 240...

Страница 25: ...dules represent an electric shock hazard due to leakage currents and the risk of shock is increased when modules are wet Before cleaning thoroughly inspect modules for cracks damage and loose connecti...

Страница 26: ...mum water pressure recommended is 4 MPa 40 bar CLEANING METHODS Method A Compressed Air Canadian Solar recommends cleaning the soft dirt like dust on modules just with air pressure This technique can...

Страница 27: ...5 CS6A 220M 220 24 8 8 87 30 6 9 31 15 CS6A 205MS 205 24 5 8 37 30 6 9 21 15 CS6A 210MS 210 24 7 8 50 30 8 9 29 15 CS6A 215MS 215 24 9 8 63 31 0 9 37 15 CS6A 220MS 220 25 1 8 76 31 2 9 45 15 CS6A 225M...

Страница 28: ...6U 400P 400 39 9 10 03 48 6 10 67 15 CS6U 405P 405 40 1 10 10 48 8 10 74 15 CS6U 290M 290 36 3 8 00 44 7 8 51 15 1960 x 992 x 40 35 77 2 x 39 1 x 1 57 1 38 in 22 4 49 4 lbs CS6U 295M 295 36 4 8 11 44...

Страница 29: ...in 12 6 27 8 lbs CS6VL 155MS 155 19 7 7 87 24 8 9 19 15 CS6VL 160MS 160 19 9 8 05 25 0 9 27 15 CS6VL 165MS 165 20 1 8 21 25 2 9 35 15 CS6VL 170MS 170 20 3 8 38 25 4 9 43 15 CS6VL 175MS 175 20 5 8 54 2...

Страница 30: ...9 64 15 CS6K 290P 290 31 6 9 18 38 5 9 72 15 CS6K 295P 295 31 8 9 28 38 6 9 81 15 CS6K 300P 300 32 0 9 38 38 8 9 92 15 CS6K 305P 305 32 1 9 50 38 9 10 03 15 CS6K 310P 310 32 3 9 60 39 8 10 22 15 CS6K...

Страница 31: ...78 7 x 39 1 x 1 57 1 38 in 22 6 22 5 49 8 49 6 lbs CS3U 355MS 355 39 0 9 11 46 8 9 61 30 CS3U 360MS 360 39 2 9 19 47 0 9 69 30 CS3U 365MS 365 39 4 9 27 47 2 9 77 30 CS3U 370MS 370 39 6 9 35 47 4 9 85...

Страница 32: ...x 40 35 65 9 x 39 1 x 1 57 1 38 in 18 5 40 8 lbs CS3K 285MS 285 31 9 8 94 38 7 9 57 30 CS3K 290MS 290 32 1 9 04 38 9 9 65 30 CS3K 295MS 295 32 3 9 14 39 1 9 73 30 CS3K 300MS 300 32 5 9 24 39 3 9 82 3...

Страница 33: ...89 35 5 9 44 15 CS1V 265MS 265 29 4 9 00 35 7 9 51 15 CS1V 270MS 270 29 6 9 11 35 9 9 59 15 CS1V 275MS 275 29 8 9 22 36 1 9 66 15 CS1V 280MS 280 30 0 9 33 36 3 9 74 15 CS1V 285MS 285 30 2 9 44 36 5 9...

Страница 34: ...1U 415MS 415 44 7 9 30 53 7 9 75 15 CS1U 420MS 420 44 9 9 37 53 8 9 80 15 CS1U 425MS 425 45 1 9 44 53 9 9 85 15 CS1U 430MS 430 45 3 9 51 54 0 9 90 15 CS1Y 380MS 380 42 7 8 89 51 5 9 74 16 2021 x 996 x...

Страница 35: ...CS3L 380P 380 34 2 11 12 41 4 11 68 20 CS3W 415MS 415 39 7 10 46 47 7 11 22 20 2108 x 1048 x 40 35 83 0 x 41 3 x 1 57 1 38 in 24 3 53 6lbs CS3W 420MS 420 39 9 10 53 47 9 11 27 20 CS3W 425MS 425 40 1 1...

Страница 36: ...80MS 280 30 9 9 07 36 8 9 57 15 CS1HA 285MS 285 31 2 9 14 37 2 9 61 15 CS3Y 420P 420 41 2 10 20 50 4 10 98 20 2252 x 1048 x 35 88 7 x 41 3 x 1 38 in 25 7 56 7 lbs CS3Y 425P 425 41 4 10 27 50 6 11 03 2...

Страница 37: ...imum power Pmax W Operating voltage Vmp V Operating current Imp A Open Circuit Voltage Voc V Short Circuit Current Isc A Max Series Fuse Rating A Overall Dimension mm Weight Kg CS3Y 500MS 500 45 0 11...

Страница 38: ...x 1 38 in 22 5 49 6 lbs CS3N 390MS 390 36 8 10 60 44 1 11 38 20 CS3N 395MS 395 37 0 10 68 44 3 11 44 20 CS3N 400MS 400 37 2 10 76 44 5 11 50 20 CS3N 405MS 405 37 4 10 83 44 7 11 56 20 CS3N 410MS 410 3...

Страница 39: ...ion mm Weight Kg CS7N 665MS 665 38 5 17 28 45 6 18 51 30 CS7L 575MS 575 33 9 16 97 40 3 18 22 30 2172 x 1303 x 35 85 5 51 3 1 38 in 31 4 69 2 lbs CS7L 580MS 580 34 1 17 02 40 5 18 27 30 CS7L 585MS 585...

Страница 40: ...1 was amended and released on Apr 2020 Rev 2 2 was amended and released on July 2020 Rev 2 3 was amended and released on Oct 2020 Rev 2 4 was amended and released on Jan 2021 Rev 2 5 was amended and r...

Отзывы: