bolt class.
In areas with heavy wind loads, additional mounting
points should be used. The system designer and the
installer are responsible for correctly calculating the
loads and ensuring that the supporting structure meets
all the applicable requirements.
Modules should be bolted at the following hole
locations depending on the configuration and loads:
Table: Approved bolting methods
Short frame four holes installation
method A
Inner four holes installation
method A
Middle four holes installation
method A
Short frame four holes installation
method B
Inner four holes installation
method B
Middle four holes installation
method B
Installation
Method
Module
Types
Short frame
four holes
installation
method A
Short frame
four holes
installation
method B
Inner four
holes
installation
method A
Inner four
holes
installation
method B
Middle four
holes
installation
method A
Middle four
holes
installation
method B
CS6AH
CS6A-P-PLUS
+5400Pa/-
2400Pa
+2400Pa/-
2400Pa
+5400Pa/-
2400Pa
+4000Pa/-
2400Pa
/
/
CS6PH
CS6P-P-PLUS
/
/
+5400Pa/-
2400Pa
+4000Pa/-
2400Pa
/
/
CS6XH
CS6X-P-PLUS
/
/
/
/
+5400Pa/-
2400Pa
+5400Pa/-
2400Pa
Note: The installation method of bolt is based on the experimental results, “/” means not tested.