| 15
CS3U-MB-FG AND CS3U-PB-FG
Clamp length ≥ 80 mm
A = 1000 mm
Maximum Load:
Uplift load ≤ 1650 Pa
Downforce load ≤ 1650 Pa
Clamp length ≥ 130 mm
A = 1000 mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
Two modules share one tube, portrait or landscape installation. Use 4 clamps on the long side of each module.
Mounting rails run parallel to the long side frame. Mounting rails fixed on torque tube (tracker).
A
A
Rail
Tube
Clamp
A
A
A
A
A
A
A
A
Tube
Clamp
Rail
Clamp
A
A
A
A
Tube
Rail
A
A
Use 4 clamps on the long side.
Mounting rails run parallel to the long side frame.
Mounting rails fixed on torque tube.
Clamp length ≥ 130 mm
A = 460 ± 20 mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
6.3
MOUNTING METHODS FOR FRAMED BIFACIAL
MODULE (BOLTING)
· The mounting method has been qualified by Canadian
Solar Inc., as well as certified by VDE and CSA.
· Modules should be bolted to support structures th-
rough the mounting holes in the rear frame flanges
only.
· Each module must be securely fastened at a minimum
of 4 points on two opposite sides.